arXiv:2604. 22700v2 Announce Type: replace Abstract: Modeling and predicting neurodegenerative disease progression from medical images remains a major challenge in medical AI, with significant implications for early diagnosis, disease monitoring, and treatment planning.
By Nivetha Jayakumar, Swakshar Deb, Bahram Jafrasteh, Qingyu Zhao, Miaomiao Zhang
arXiv:2610.25481v2 Announce Type: replace-cross
Abstract: Spatiotemporal forecasting of 3D anatomical changes is a critical generative vision challenge for modeling Alzheimer's Disease (AD) progressi...
By Antonio Scardace, Silvia Ingala, Sebastiano Battiato, Daniele Rav\`i
The paper introduces CM-RED, a fast MRI reconstruction method that combines a pretrained consistency model with the regularization by denoising framework. By integrating controlled noise injection into accelerated proximal gradient updates, CM-RED achieves high‑quality reconstructions on fastMRI knee and brain datasets with only four network function evaluations. It consistently outperforms existing diffusion‑ and consistency‑based approaches in quantitative metrics, visual fidelity, and robustness to hyperparameter changes.
By Merve G\"ulle, Junno Yun, Ya\c{s}ar Utku Al\c{c}alar, Mehmet Ak\c{c}akaya
arXiv:2606. 18354v1 Announce Type: cross Abstract: Recent advances in generative machine learning models have significantly improved medical imaging, offering promising solutions for data augmentation, privacy preservation, and improved model generalization.
By Muge Zhang, Muhammad Ali Khaliq, Jamal Alsakran, Byeong Kil Lee, Jeeho Ryoo
The paper introduces a 3D residual wavelet diffusion model for super‑resolving ultra low‑field MRI scans. By using a lossless wavelet reparameterisation, residual shifting, and domain randomisation, the method fits whole‑brain data on a single GPU, speeds up sampling, and generalises across scanners. It achieves volumetric accuracy comparable to leading regression approaches while producing per‑voxel uncertainty maps that reveal under‑determined regions and preserves disease‑relevant atrophy in cognitively impaired subjects.
By Rui W. Yeow, Millie Beament, Fred Dick, Raha Razin, Martina Bocchetta, David L. Thomas, Henry F. J. Tregidgo, Daniel C. Alexander, James H. Cole
arXiv:2606. 15457v1 Announce Type: cross Abstract: 3D FLAIR MRI is widely recommended as one of the standard MRI sequences for brain imaging in multiple sclerosis (MS), but publicly available MS datasets remain relatively small and vary across scanners, acquisition protocols, and lesion patterns.
By Weidong Zhang, Yongchan Jung, Shafayat Mowla Anik, Furen Xiao, Vasudevan Janarthanan, Enkhzaya Chuluunbaatar, Byeong Kil Lee, Jeeho Ryoo