The paper introduces MR‑DiffuSR, a 3‑D latent diffusion framework that uses high‑resolution T1w structural priors to guide super‑resolution of thick‑slice FLAIR MRI scans. By applying cross‑modality structural swin attention and a mixed‑scale degradation strategy, the method avoids hallucinations and remains robust across varying slice thicknesses. On ADNI datasets, MR‑DiffuSR outperforms CNN and 2‑D diffusion baselines, achieving high PSNR, SSIM, and low LPIPS, and maintains strong white‑matter hyperintensity segmentation performance even at 7 mm equivalent slice thickness.
By Haoyu Lan, Jiazhen Zhang, John Onofrey, Bino Varghese, Nasim Sheikh-Bahaei, Arthur W. Toga, Jeiran Choupan
The paper introduces a transfer‑learning framework that pre‑trains an implicit neural representation (INR) on a high‑resolution diffusion MRI template and then adapts it to individual subjects through registration and fine‑tuning. This approach enables native single‑subject super‑resolution, achieving a 4× through‑plane up‑sampling from 5 mm to 1.25 mm on Human Connectome Project data. Compared to a recent baseline, the method reduces NRMSE by 36–49 % and increases FSIM by 24–43 %, while training 6× faster and outperforming other INR‑based techniques on both image quality and domain‑specific metrics.
By Abdulkader Ghandoura, Marsil Zakour, William Consagra, Yogesh Rathi
arXiv:2609.24265v1 Announce Type: cross
Abstract: Unsupervised anomaly detection (UAD) aims to localize abnormal regions in medical scans without pixel-level annotations. A typical strategy seeks to...
By Hugues Roy, Reuben Dorent, Ninon Burgos
arXiv:2606. 24313v1 Announce Type: new Abstract: AI-driven image-to-image synthesis is rapidly advancing, with growing applications in medical imaging.
By Martin Valls (UFR SFA), Pascal Bourdon (UFR SFA), Christine Fernandez-Maloigne (LabCom I3M), Guillaume Herpe (CHU Poitiers -- Radio, DACTIM-MIS), David Helbert (UFR SFA)
arXiv:2603. 05693v2 Announce Type: replace-cross Abstract: Accurate longitudinal analysis of brain MRI is often hindered by evolving lesions, which bias automated neuroimaging pipelines.
By Zahra Karimaghaloo, Dumitru Fetco, Haz-Edine Assemlal, Hassan Rivaz, Douglas L. Arnold
arXiv:2610.17401v1 Announce Type: new
Abstract: Incomplete field-of-view (FOV) diffusion MRI (dMRI) acquisitions compromise whole-brain white matter analysis by excluding brain regions from tractogra...
By Gaurav Rudravaram, Lianrui Zuo, Ema Topolnjak, Michael E. Kim, Adam M. Saunders, Elyssa M. McMaster, Paula Trujillo, Ely E. Wesley, Colin D. McKnight, Pratik P. Pandharipande, Mayur B. Patel, Cayce Strength, Brenda T. Pund, Amelia W Maiga, Robert S. Dittus, David A. Bennett, Julie A. Schneider, Konstantinos Arfanakis, The HABS-HD Study Team, Derek B. Archer, Timothy J. Hohman, Yelena Bodien, Daniel C. Moyer, Kurt G. Schilling, Bennett A. Landman
arXiv:2607. 11533v1 Announce Type: cross Abstract: Perineural invasion (PNI) is a critical prognostic factor in cholangiocarcinoma.
By Youngung Han, Dohyun Kweon, Kyeonghun Kim, Hyunsu Go, Jina Jeong, Suah Park, Induk Um, Junga Kim, Anna Jung, Yului Jeong, Sungha Park, Jinyong Jun, Pa Hong, Woo Kyoung Jeong, Won Jae Lee, Ken Ying-Kai Liao, Hyuk-Jae Lee, Nam-Joon Kim
AI-driven image-to-image synthesis is rapidly advancing, with growing applications in medical imaging. Multi-modal image analysis plays a crucial role in optimizing examination quality, yet acquiring multiple imaging modalities in clinical settings remains resource-intensive and time-consuming, especially for 3D imaging.
arXiv:2610.09376v1 Announce Type: new
Abstract: Acquiring a complete set of magnetic resonance imaging (MRI) contrasts is time-intensive and uncomfortable for patients, despite the diagnostic value o...
By Yejee Shin, Geonhui Son, Jinglu Wang, Minwoo Jung, Yan Lu, Dosik Hwang
The paper introduces a subject‑specific spatial‑angular Gaussian field for self‑supervised joint k‑q diffusion MRI reconstruction. It uses shared 3D Gaussian primitives that provide local spatial support while each primitive carries a continuous q‑conditioned tensor‑residual response, allowing the signal at each location to be synthesized from overlapping primitive responses. Experiments on three HCP diffusion shells with various acceleration settings show consistent improvements in missing‑direction DWI reconstruction, tensor‑derived metrics, and principal diffusion orientation estimation.
By Zhibo Chen, Yajuan Huang, Yu Guan, Qiuyun Fan, Dong Liang, Qiegen Liu
The paper introduces DB‑SUiT, a surface‑based diffusion bridge that translates cortical MRI to PET images directly on the cortical manifold. It employs a conditional spherical U‑shaped vision Transformer to capture multi‑scale surface features and long‑range dependencies while incorporating demographic and subcortical information. Evaluations on two dementia datasets show that the synthesized PET surfaces outperform MRI and PET volumes in automated classification and achieve high diagnostic accuracy in a blinded reader study.
By Yitong Li, Alexandra Samoylova, Fabian Bongratz, Timo Grimmer, Dennis M. Hedderich, Igor Yakushev, Christian Wachinger
arXiv:2606. 26764v1 Announce Type: cross Abstract: Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions.
By Yiheng Cao, Gustavo Andrade-Miranda, Jiatian Zhang, Lingxiao Zhao, Xin Gao