The paper investigates whether machine unlearning algorithms preserve the same feature representations as models retrained from scratch after data deletion. It shows that models can agree on outputs yet encode different features, and that even deleting a tiny fraction of data can lead retraining to learn qualitatively different features. The authors propose a feature‑recovery metric that distinguishes missing from extraneous features and find that many unlearning methods that score well on standard metrics fail to recover the retrained features, leading to deviations in relearning and downstream tasks.
By Polina Dolgova, Amartya Sanyal, Sebastian U. Stich
arXiv:2608. 13711v1 Announce Type: cross Abstract: Computer-aided detection (CADe) systems for colonoscopy promise to reduce clinical miss rates, yet reliable real-world deployment remains elusive.
By Sebastian Doerrich, Andreas Franz Schwab, Francesco Di Salvo, Shyam Nandan Rai, Hanh Huyen My Nguyen, Christian Ledig
arXiv:2608. 16198v1 Announce Type: cross Abstract: Dermatology models face distribution shifts in teledermatology settings, where submitted images differ from the training data in lighting, angle, distance, focus, and framing.
By Fabian Gr\"oger, Marco Weishaupt, Philippe Gottfrois, Simone Lionetti, Linda Wermelinger, Nipun Ranasekara, Ludovic Amruthalingam, Alexander A. Navarini, Marc Pouly
arXiv:2608. 09460v1 Announce Type: new Abstract: Cardiac digital twin research is moving from subject-specific anatomical replicas toward virtual cohorts that represent clinically relevant population subgroups.
By Konstantinos Kevopoulos, Beatrice Moscoloni, Benjamin Alheit, Cameron Beeche, Julio A. Chirinos, Alexander Heinlein, Mathias Peirlinck
arXiv:2606. 10877v1 Announce Type: new Abstract: Occlusion-based attribution methods provide an intuitive way to estimate feature importance by perturbing input features and measuring the resulting change in model output.
By Thodoris Lymperopoulos, Ioannis Kakogeorgiou, Denia Kanellopoulou
arXiv:2606. 09601v1 Announce Type: new Abstract: Conditional generators provide a natural tool for controllable generation, including settings where the desired condition is a new composition of observed attributes or experimental factors.
By Berker Demirel, Valentino Maiorca, Marco Fumero, Theofanis Karaletsos, Francesco Locatello
The paper introduces SPAR‑Bench, a set of eight probes designed to test whether medical vision models can reason about anatomy in abdominal CT scans. Experiments across five architectures and three foundation models—both frozen and fine‑tuned—show that while models can recall canonical organ locations, they fail to perform relational reasoning or spatial comparisons within a patient, even under zero‑shot transfer. The study also demonstrates that pooled probing underestimates a model’s relational capabilities and that open‑weight multimodal large language models perform poorly on these tasks.
By Naren Akash, Neeraja Ramanan
arXiv:2607. 05965v1 Announce Type: cross Abstract: Vascular computed tomography datasets are commonly annotated only once per scan, yielding the pervasive yet under addressed problem of single mask annotation noise.
By Yinheng Zhu, Xiaowei Xu
arXiv:2609.35470v1 Announce Type: cross
Abstract: Applied researchers increasingly convert images into features with pretrained encoders, then use those features in a downstream prediction model. The...
By Ardyn Nordstrom, Morgan Nordstrom, Vamuyan Sesay, Matthew D. Webb
The paper introduces CARDIAG, a multi‑center benchmark dataset for fine‑grained SYNTAX segmentation of coronary angiograms, featuring highly imbalanced multi‑class labels, catheter and stenosis masks, expert uncertainty maps, temporal frames, and spatial metadata. The authors conduct an extensive architectural sweep of 24 models—including CNNs, Vision Transformers, and State‑Space Models—using advanced metrics such as clDice, vessel diameter error, and uncertainty error‑detection. Their findings show that large‑kernel CNNs (ConvNeXt V2 with DeepLabV3+) outperform recent ViTs and SSMs, achieving a Dice score of 0.456, which improves to 0.479 with model ensembling, while also exploring out‑of‑distribution generalization through leave‑one‑center‑out cross‑validation.
By Dominik Bernard Lau, Jerzy Szyjut, Hubert Malinowski, Adam Brzeski, Tomasz Dziubich, Natalia Zieli\'nska, Tomasz Figatowski, Rados{\l}aw Targo\'nski
The paper introduces EAMS, an Equivariant Anatomical Mesh Segmentor that operates directly on irregular surface geometry and remains robust to coordinate pose changes across meshes of varying resolution. Built on Equivariant Mesh Neural Networks (EMNN), EAMS combines intrinsic mesh descriptors with anatomy-aware priors, such as PCA-derived frames for dental arches and liver surfaces, and augments message passing to provide lightweight global context. Evaluated across four datasets and three clinical application areas, EAMS variants perform competitively on unperturbed inputs while maintaining stability under geometric perturbations, demonstrating that a lightweight (<2 M parameters) equivariant framework can achieve robust anatomical mesh segmentation across diverse label types.
By Daniel Saragih
The paper introduces GRACE, a retrieval‑augmented refiner that improves automated medical image segmentation masks by leveraging a shared knowledge base of verified prior cases. Trained once on a multi‑organ corpus, GRACE can refine masks across diverse anatomies and imaging modalities, achieving significant Dice score gains especially for weak segmentors. The method demonstrates that a single, parameter‑free model can replace anatomy‑specific correction models, with performance evaluated on 18 public datasets and seven upstream segmentors.
By Vincenzo Marcian\`o, Xiaoming Zhang, Michela Antonelli, Sebastien Ourselin, Maria A Zuluaga