arXiv:2609.15130v1 Announce Type: cross
Abstract: woma is a real-time foundation model for gastrointestinal endoscopy: a network trained without labels on about a million endoscopy frames, from which...
By Thang Tran, Lan Dang
The paper introduces CARDIAG, a multi‑center benchmark dataset for fine‑grained SYNTAX segmentation of coronary angiograms, featuring highly imbalanced multi‑class labels, catheter and stenosis masks, expert uncertainty maps, temporal frames, and spatial metadata. The authors conduct an extensive architectural sweep of 24 models—including CNNs, Vision Transformers, and State‑Space Models—using advanced metrics such as clDice, vessel diameter error, and uncertainty error‑detection. Their findings show that large‑kernel CNNs (ConvNeXt V2 with DeepLabV3+) outperform recent ViTs and SSMs, achieving a Dice score of 0.456, which improves to 0.479 with model ensembling, while also exploring out‑of‑distribution generalization through leave‑one‑center‑out cross‑validation.
By Dominik Bernard Lau, Jerzy Szyjut, Hubert Malinowski, Adam Brzeski, Tomasz Dziubich, Natalia Zieli\'nska, Tomasz Figatowski, Rados{\l}aw Targo\'nski
SpineContextResUNet is a lightweight 3D Residual U‑Net that uses a Context Block with parallel multi‑dilated convolutions to efficiently capture long‑range anatomical dependencies for spine CT segmentation. It achieves Dice scores of 88.17% on VerSe2020 and 88.13% on CTSpine1K while maintaining a small ~1.7 M parameter footprint. Compared to resource‑heavy Transformers and baselines that fail on commodity hardware, SpineContextResUNet delivers robust inference on edge devices such as the Nvidia Jetson Orin Nano.
By K S Nithurshen, Saurabh J. Shigwan
arXiv:2609.10495v1 Announce Type: new
Abstract: In real-time colonoscopy, ground-truth annotations are unavailable at inference, so polyp segmentation models can fail silently. We propose Referee-Bas...
By Siddharth Gupta, Jitin Singla
arXiv:2608. 12086v1 Announce Type: cross Abstract: Vision-language models, such as contrastive language-image pre-training (CLIP)-based approaches, have reached state-of-the-art (SOTA) results in medical artificial intelligence.
By Nikolette Pedersen, Regitze Sydendal, Veronika Cheplygina, Th\'eo Sourget
The paper introduces TopKSigLIP, a vision‑language model tailored for mammography that tackles two key challenges: high‑resolution imaging and homogeneous radiology reports. It replaces standard CLIP training with a TopK‑Patch module that selects sparse high‑resolution patches likely to contain lesions, and a Sup‑sigmoid loss that uses soft labels from structured data instead of contrastive loss. TopKSigLIP outperforms existing open‑source mammography and general medical VLMs on zero‑shot tasks such as density assessment, BI‑RADS classification, finding subtyping, and cancer prediction, while also providing better lesion localization than Grad‑CAM.
By Young Seok Jeon, Beatrice Brown-Mulry, Rohan Satya Isaac, Anjana Dissanayaka, Theo Dapamede, Mohammadreza Chavoshi, Judy Gichoya, Hari Trivedi
arXiv:2608. 11770v1 Announce Type: cross Abstract: Edge-deployed vision systems in target recognition, surveillance, autonomous vehicles, and drone domains require hierarchical inference pipelines where a detection model identifies objects of interest and downstream classifiers provide fine-grained attribute analysis.
By Vaishnav Raju
The paper introduces a reference-guided data curation method for training 3D medical vision‑language models. By using a small, high‑quality reference set to extract quality signals from large, uncurated image‑report pools and aggregating these signals into a single ranking, the authors can select a subset of data that yields competitive zero‑shot disease classification performance. Experiments on 35k 3D abdominal CT pairs and 58k 2D chest X‑ray pairs show that the curated models match or exceed baseline performance while using up to ten times less training data.
By Faidra Patsatzi, Ashwin Kumar, Chong Wang, Curtis P. Langlotz, Reinhard Heckel, Akshay S. Chaudhari
arXiv:2605. 30716v2 Announce Type: replace-cross Abstract: Generating clinically useful pathology reports for pathology cases from whole-slide images (WSIs) is challenging due to gigapixel resolution, long visual-token sequences, and the complexity of case-level reasoning, where a single case may contain multiple WSIs with heterogeneous tissues and ambiguous findings.
By Zhiyuan Yang, Jiahao Cheng, Vincent Quoc-Huy Trinh, Mahdi S. Hosseini
The paper introduces DMSNet, a deformable adaptive multi‑scale edge‑guided attention network for video capsule endoscopy (VCE) classification. It evaluates DMSNet and 18 other architectures on the Kvasir‑Capsule dataset using both random frame‑level and source‑video‑disjoint validation protocols, reporting MCC scores of 0.442 and 0.456 respectively. The study also examines cross‑dataset performance on CV2024, the impact of source‑video diversity, and shows that model rankings and accuracy vary significantly with validation protocol, training source diversity, and external dataset shift.
By Smriti Regmi, Debesh Jha
SegMate is a lightweight 2.5D framework for multi‑organ medical image segmentation that combines asymmetric architectures, attention mechanisms, multi‑scale feature fusion, slice‑based positional conditioning, and multi‑task optimization. Across three modern backbones and datasets (TotalSegmentator, SegTHOR, AMOS22), it reduces computation by up to 2.5× and memory usage by up to 2.1× while improving accuracy by about 1%, achieving a Dice score of 93.51% on TotalSegmentator with only 295 MB peak GPU memory. The model supports high‑throughput processing, enabling up to 10,000 volumes per hour on a single GPU with 74 J per volume, and demonstrates strong zero‑shot generalization to other datasets.
By Andrei-Alexandru Bunea, Dan-Matei Popovici, Radu Tudor Ionescu
The paper introduces Diagnostic Loss (DLoss), an objective designed to align radiology report generation with the asymmetric requirement of accurately stating supported diagnoses while avoiding unsupported ones. DLoss operates on decoder token probabilities, aggregating mass over vocabularies for supported and unsupported diagnoses and applying asymmetric pooling to encourage correct diagnoses and suppress spurious ones. Applied to various 3D MedVLMs on 50,000 abdominal CT scans, DLoss improves diagnostic faithfulness without compromising conventional language‑generation metrics.
By Ignacy Kolton, Wenxuan Li, Zongwei Zhou, Jaros{\l}aw B. \'Cwik{\l}a, Arkadiusz Sitek, Pedro R. A. S. Bassi, Szymon P{\l}otka