Computational Analysis of Heart Rate Variability in Healthy Adults
arXiv:2606. 26816v1 Announce Type: new Abstract: Heart Rate Variability (HRV) analysis is a key indicator of cardiac physiological state and aids in disease diagnosis.
arXiv:2606. 26816v1 Announce Type: new Abstract: Heart Rate Variability (HRV) analysis is a key indicator of cardiac physiological state and aids in disease diagnosis.
ARTA is a graph‑based combinatorial framework that improves interbeat interval estimation from wearable ECG by integrating candidates from multiple detectors into a directed acyclic graph. It uses detector agreement, ECG quality, and history‑dependent transition costs to select a coherent heartbeat sequence via beam‑search dynamic programming, effectively suppressing false detections and recovering missed beats. On benchmark datasets, ARTA reduces heart‑rate mean absolute error by 54% compared to the best single detector and achieves high accuracy in R‑peak detection and IBI estimation while remaining lightweight and training‑free.
arXiv:2608. 00058v1 Announce Type: cross Abstract: Accurate measurement of ECG intervals, including PR, QRS duration, and QT/QTc, is central to cardiac diagnosis, yet the published ECG delineation literature evaluates performance almost exclusively as fiducial-point timing errors on small curated databases, rather than as clinical interval accuracy on large unselected cohorts.
arXiv:2608. 07759v1 Announce Type: cross Abstract: Cardiovascular AI models can classify clean elec- trocardiogram (ECG) signals, but real wearable signals change because of motion, breathing, posture, sensor contact, and true clinical deterioration.
PPG-Bench is an open‑source benchmark that evaluates five publicly available photoplethysmography (PPG) foundation models across nine datasets and 26 tasks, covering cardiovascular state estimation, activity, sleep, screening, and identification. The benchmark tests models under four downstream regimes—linear probing, random forests, frozen MLP probes, and end‑to‑end finetuning—while also comparing them to three controls: a random/constant baseline, a deterministic pulse‑rate‑variability feature set, and a generic time‑series foundation model (MOMENT). Results show that over a third of task‑regime combinations yield no advantage for any PPG foundation model over the baseline, and in most cases no PPG‑specific model outperforms the simple controls, indicating that current PPG foundation models lack generalised, transferable representations.
arXiv:2608. 03597v1 Announce Type: new Abstract: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and is associated with increased risks of stroke, heart failure, and mortality.
arXiv:2607. 23412v1 Announce Type: new Abstract: Electrocardiograms (ECGs) are widely used for cardiovascular risk prediction, yet models often fail to transfer across hospitals because of protocol, population, and measurement differences.
The paper introduces TF‑IG, a compact two‑branch model that learns heart‑rate from photoplethysmography by combining temporal pulse morphology and frequency‑domain periodicity. A novel interaction‑gated fusion module explicitly models agreement and discrepancy between the two domains, while a shared regression head maps the fused features to HR predictions. On the BIDMC PPG dataset, TF‑IG achieves a mean absolute error of 1.227 BPM and 92.28 % of estimates within 3 BPM using only 84.6 K parameters.
arXiv:2607. 27404v1 Announce Type: new Abstract: Existing benchmarks for electrocardiogram foundation models primarily evaluate downstream predictive performance, providing limited insight into whether their internal representations can be faithfully decomposed, clinically interpreted, or reproduced across independent analyses.
The study re‑examines heart rate variability (HRV) as a non‑invasive biomarker for glucose status, using 43 male type‑2 diabetes patients and rigorous leave‑one‑subject‑out cross‑validation. Despite testing 20 machine‑learning models, six age‑adjustment methods, and 20 normalisation schemes, no age‑normalisation improved predictive performance; Extra Trees regression yielded the best results (R²=0.222 for HbA1c and R²=0.086 for fasting blood glucose). The findings confirm HRV–glycemic associations but indicate that current models are not yet clinically useful, underscoring the need for strict validation and preprocessing in future research.
CardioFusion-AI is a framework for robust fusion of ECG and PPG signals in wearable physiological monitoring. Its signal‑processing front end, featuring R‑peak and systolic‑peak detection, an Orphanidou‑type signal‑quality index, and beat‑by‑beat pulse transit time estimation, was validated on 53 intensive‑care recordings and a fetal ECG database. In a controlled synthetic degradation study, attention fusion achieved the lowest overall error, while adaptive gates reallocated weight toward the healthy modality under complete loss, and signal‑quality conditioning improved performance when PPG was missing.
Wearable electrocardiogram (ECG) and photoplethysmogram (PPG) sensors are complementary but individually fragile: motion artifact, poor contact, and sensor dropout can degrade one or both signals. Fus...