The paper presents a modality‑routed 3D cardiac segmentation pipeline that combines TotalSegmentator‑initialized nnU‑Netv2 models with site‑characterized, label‑preserving appearance augmentation. By analyzing measurable image properties across sites, the authors design a bias‑field plus Bezier augmentation strategy that smooths spatial intensity perturbations and remaps intensities nonlinearly, followed by class‑wise largest‑connected‑component cleanup. On held‑out validation splits, this approach raises CT mean Dice from 0.8350 to 0.9135 and MRI mean Dice from 0.7695 to 0.7830 while reducing HD95, demonstrating improved cross‑site robustness in limited‑data whole‑heart segmentation.
By Tanish Mudaliar, Justin Li, Daniel Lin, Julianna Vo, Kaitao Liao, Xin Wang, Shu Hu
arXiv:2602.20773v2 Announce Type: replace
Abstract: Purpose: Developing generalizable medical image segmentation models is challenging because imaging data are distributed across institutions and dif...
By Sachin Dudda Nagaraju, Ashkan Moradi, Bendik Skarre Abrahamsen, Mattijs Elschot
arXiv:2608.31073v1 Announce Type: new
Abstract: Whole-heart segmentation (WHS) in computed tomography (CT) and magnetic resonance imaging (MRI) is affected by acquisition shifts and heterogeneous car...
By Jiacheng Wang, Ivana Isgum, Ipek Oguz
arXiv:2606. 10713v1 Announce Type: cross Abstract: The nnU-Net has demonstrated continuous success in medical segmentation tasks, which heavily rely on the availability and diversity of annotated biomedical data.
By Ana Sofia Santos, Andr\'e Ferreira, Gijs Luijten, Naida Solak, Lisle Faray de Paiva, Behrus Hinrichs-Puladi, Jens Kleesiek, Jan Egger, Victor Alves
The paper presents the first systematic evaluation of out‑of‑distribution generalization for congenital heart disease (CHD) segmentation, using the ImageCHD cohort as a held‑out target. It compares several segmentation architectures under different training regimes, showing that in‑distribution performance is a poor predictor of cross‑cohort robustness: nnU‑Net drops from 0.77 to 0.51 Dice, while SwinUNETR maintains higher performance at 0.67 Dice. Limited target‑domain adaptation with only 11 labeled ImageCHD cases boosts all SwinUNETR variants above 0.76 Dice, highlighting the importance of explicit cross‑dataset testing.
By Aniketh Vijesh, Shrisharanyan Vasu, Abhijit Ramesh, Clare Pomeroy-Ward, Harikrishnan Anil Maya, Sarin Xavier, Mahesh Kappanayil, Gilad Gressel
Congenital heart disease (CHD) diagnosis and surgical planning often require patient-specific 3D anatomical models, but manual segmentation is labor-intensive, particularly in complex anatomies. Altho...
arXiv:2606. 13188v1 Announce Type: cross Abstract: Building patient-specific cardiac models sits at the heart of precision cardiology, yet getting those models into clinical use keeps running into the same wall: mesh generation is slow, messy, and frustrating.
By Abhishek H S, Akash Ganamukhi, Abhimanyu Suresh, Aditya G Hiremath, Prasad B Honnavalli, Adithya Balasubramanyam
CMRVision is a cardiac magnetic resonance (CMR) foundation model trained with DINOv3-style self‑supervised learning on 36 million multi‑center, multi‑sequence CMR images. It outperforms prior natural‑image, medical‑image, supervised, and CMR baselines on multi‑task segmentation (cine, LGE, mapping) and cine view classification, achieving Dice scores of 0.940–0.967 for LV and 0.855–0.905 for myocardium, and a zero‑shot Dice of 0.692 on unseen LGE long‑axis views. The model demonstrates robust cross‑view generalization and highest average accuracy (0.906) for cine view classification.
By Athira J. Jacob, Puneet Sharma, Daniel Rueckert
arXiv:2610.09784v1 Announce Type: new
Abstract: Reliable liver segmentation in contrast-enhanced MRI is essential for quantitative hepatic assessment, treatment planning, and longitudinal disease mon...
By Ruoshi Xu, Mingqi Gao, Shengda Luo, Jingkun Chen
arXiv:2609.21412v1 Announce Type: new
Abstract: Medical image segmenters often get worse when sites, scanner vendors, or protocols change. Continual test-time adaptation (CTTA) addresses this problem...
By Ruijie Huang
arXiv:2607. 11287v1 Announce Type: cross Abstract: Comprehensive quantification of cardiac structures from computed tomography (CT) remains limited not by data availability but by the scalability of measurements, which makes routine use impractical.
By Pooya Mohammadi Kazaj, Leo Fridolin Weber, Wen Xie, Seyed Amir Ahmad Safavi-Naini, Anselm Stark, Giovanni Baj, Ali Mokhtari, Toshiya Yoshida, Christoph Ryffel, Taishi Okuno, Yoshihiro Akashi, Ronny R. Buechel, Thomas Pilgrim, Waldo Valenzuela, George C. M. Siontis, Xiaowei Xu, Moritz Hundertmark, Stephan Windecker, Christoph Grani, Isaac Shiri
arXiv:2606. 00491v1 Announce Type: cross Abstract: Deep learning-based CT segmentation systems often achieve high accuracy on clean benchmark images, but their performance may degrade under heterogeneous clinical imaging conditions such as noise, resolution loss, contrast variation, intensity shift, and artifacts.
By CholMin Kang, Jonghyun Chung, Amanpreet Kaurb, Nagesh Gulkotwarb, Arthi Sivasankaranb