arXiv Computer Vision

Generalizable fetal brain biometry via adaptive artificial intelligence

The paper introduces BioTTA, an anatomically guided test‑time adaptation framework that measures 11 fetal brain biometrics from 3D MRI. By adapting pretrained models to individual unlabeled volumes using geometric consistency and atlas priors, BioTTA improves measurement accuracy across out‑of‑distribution datasets and network architectures, reducing mean absolute errors by 46‑82%. The resulting measurements are mapped onto normative growth trajectories and used in a web‑based platform that achieves 82.1‑95.0% accuracy in detecting ventriculomegaly or cerebellar abnormalities, comparable to a senior radiologist.

arXiv AI
Aug 18

Cross-Modal Ultrasound-MRI Learning for Fetal Brain Ventricular Volumetry and Abnormality Screening

arXiv:2608. 14763v1 Announce Type: cross Abstract: Assessment of ventriculomegaly (VM) on fetal brain ultrasound relies primarily on measuring lateral ventricular atrial width on standard planes, which is operator-dependent and may not fully reflect the overall ventricular enlargement.

By Yuhao Huang, Yuanji Zhang, Yuhuan Lu, Dong Ni, P. Ellen Grant, Davood Karimi
arXiv AI
Jul 22

FedCC: A Low-Resource Federated Adaptation of Foundation Models for Robust Corpus Callosum localization in Fetal Ultrasound Images

arXiv:2607. 18283v1 Announce Type: cross Abstract: Accurate localization of the corpus callosum (CC) in fetal ultrasound (US) images is crucial for the early identification of neurodevelopmental abnormalities.

By Alessandro Di Matteo, Sara Moccia, Giuseppe Rizzo, Gianpaolo Grisolia, Ricciarda Raffaelli, Lorenzo Vasciaveo, Francesco D'Antonio, Maria Chiara Fiorentino
arXiv AI
Jul 23

PRIME-SVR: Physics-infoRmed Implicit Multi-Echo Slice-to-Volume Reconstruction for Fetal T2 mapping

arXiv:2607. 20136v1 Announce Type: cross Abstract: Slice-to-volume reconstruction (SVR) is the standard method for obtaining high-resolution (HR) 3D fetal brain volumes from motion-corrupted 2D MRI slice stacks acquired in multiple orientations.

By Busra Bulut, Maik Dannecker, Thomas Sanchez, Sara Neves Silva, Steven Jia, Jean-Baptiste Ledoux, Leo Pomar, Joanna Sichitiu, Yvan Gomez, Meriam Koob, Vincent Dunet, Maria Deprez, Guillaume Auzias, Francois Rousseau, Jana Hutter, Daniel Rueckert, Meritxell Bach Cuadra
arXiv AI
Oct 15

FETALFusion: Resolution-Aware State-Space Modeling for Multi-Domain Fetal Head Segmentation

FETALFusion is a dual‑path CNN‑Mamba encoder‑decoder designed for fetal head segmentation in 2D ultrasound across transabdominal and transperineal acquisition types. It uses four‑directional state‑space scans at the highest‑resolution stages, domain‑specific channel gates, and a weak landmark shape prior, achieving a Dice score of 0.963 and an HD95 of 2.10 mm on a held‑out test set of 471 images. Ablation studies show that the landmark prior and domain gates drive most of the performance gains, while the state‑space branch has minimal impact. whyItMatters":"The method provides highly accurate fetal head segmentation without test‑time augmentation or domain labels, enabling reliable head circumference measurement for monitoring fetal growth."

By Ammar Bhilwarawala, Mainak Bandyopadhyay
arXiv Computer Vision
Sep 28

Towards Whole-Study Screening for Congenital Heart Disease in Fetal Ultrasound Using Multiple Instance Learning

The paper presents a two‑stage framework for prenatal congenital heart disease (CHD) screening that operates directly on whole fetal ultrasound studies. It first learns transferable frame representations via self‑supervised masked‑autoencoder pre‑training, then identifies cardiac frames with a disease‑robust module and aggregates them using a transformer‑based multiple instance learning model to produce a case‑level diagnosis. The approach achieves high performance (AUC 0.985, specificity 0.990) on an internal test set and, after label‑free CORAL adaptation, improves to an AUC of 0.944 on an external cohort, outperforming existing baselines.

By Mohamed Azzam, Ruobing Liu, Esther C. Ugwueke, Ziyang Xu, Shibiao Wan, Alex Foy, Abraham Zabih, Jason Christensen, Neil Hamill, Ling Li, Jieqiong Wang
arXiv AI
Sep 18

A Two-Stage Multi-Modal MRI Framework for Lifespan Brain Age Prediction

The paper introduces a two-stage multi‑modal MRI framework that processes different MRI modalities independently before integrating them through late fusion. First, the model estimates a probability distribution over six developmental stages, then it predicts age using probability‑weighted, stage‑specialized experts. Experiments across nine datasets—from fetal to elderly—show the method outperforms existing baselines, reducing mean absolute error by 13% and 78% in in‑domain and out‑of‑domain settings, and multi‑modal integration yields 12‑13% performance gains. Analysis on ADNI clinical groups indicates that the predicted brain age gap could help characterize Alzheimer’s‑related brain aging.

By Dingyi Zhang, Ruiying Liu, Yun Wang
arXiv AI
Sep 7

Measuring proximity to standard planes during fetal brain ultrasound scanning

This study introduces a pipeline that enhances ultrasound plane pose estimation for fetal brain imaging by providing continuous, real‑time proximity feedback to standard planes (SPs). It employs a semi‑supervised segmentation model achieving high mIoU scores on both SPs and non‑SPs, and integrates a classification step to filter out frames without the fetal brain. The system, validated on an NVIDIA Clara AGX edge device, runs at 39 Hz and has been tested on real scan videos from 17 sonographers, demonstrating its practical viability for clinical use.

By Chiara Di Vece, Antonio Cirigliano, Meala Le Lous, Raffaele Napolitano, Anna L. David, Donald Peebles, Pierre Jannin, Francisco Vasconcelos, Danail Stoyanov
arXiv AI
Jun 24

Female-RHINO: A Real-Time Scanner-Integrated Framework for Automated Quantitative Uterine MRI Analysis and Structured Reporting

arXiv:2606. 24390v1 Announce Type: cross Abstract: Standardized assessment of uterine MRI remains challenging due to anatomical variability, observer dependence, and the lack of workflow-integrated automated analysis tools.

By Deepak Bhatia, Saad Ahmad, Smiti Tripathy, Maria Camila Bustos Vivas, Lieselotte Kratzsch, Anika Knupfer, Jordina Aviles Verdera, Susanne Schulz-Heise, Matthias May, Jana Hutter
arXiv Computer Vision
Sep 22

AWR-Net: Decoupling Anatomy and Appearance for 3D Fetal Brain Ultrasound Synthesis

The paper introduces AWR-Net, a two‑stage framework that decouples anatomy and appearance to synthesize realistic 3D fetal brain ultrasound volumes from anatomical label maps. The first stage uses wavelet diffusion to generate volumes from atlas pairs in the wavelet domain, while the second stage applies residual refinement in the image domain to adapt to real ultrasound appearance. Experiments on real fetal brain ultrasound data show that AWR‑Net outperforms existing synthesis methods, improving metrics such as normalized cross‑correlation and Fréchet Inception Distance, and also enhances downstream segmentation, especially for severe abnormal cases.

By Yuhuan Lu, Sergio Valencia, Yuanji Zhang, Yuhao Huang, Camilo Jaimes, P. Ellen Grant, Davood Karimi