arXiv:2606. 17437v1 Announce Type: cross Abstract: Automated classification of standard echocardiographic views is crucial for efficient clinical workflow but faces three main challenges.
By Bo Gou, Jicheng Zhang, Jianlong Xiong, Tao He, Bentian Liu, Hai Wu, Yijiao Wang, Yu Zhang, Yujia Yang, Yun Dai, Jian Liu, Jie Wang
The paper presents a hybrid CNN–state‑space–attention backbone designed for 12‑lead ECG classification, combining early waveform tokenization, mixed temporal dynamics modeling, and late global attention. It introduces an ECG‑oriented Joint‑Embedding Predictive Pretraining (JEPA) that samples span masks at latent resolution and predicts clean latent targets via a momentum encoder, avoiding waveform reconstruction. Experiments on CPSC2018, Chapman‑Shaoxing, and PTB‑XL, with pretraining on ~350K unlabeled CODE‑15 recordings, demonstrate strong supervised baselines and improved transfer, especially in low‑label scenarios and with LoRA adaptation.
By Yakoub Bazi, Sarah Aljuhani, Mohamad M. Al Rahhal, Mansour Zuair, Naif Alajlan
arXiv:2606. 11922v1 Announce Type: cross Abstract: Recent respiratory sound classification (RSC) studies largely rely on CLS-token driven self-attention architectures such as the Audio Spectrogram Transformer (AST).
By Hemansh Shridhar, Miika Toikkanen, June-Woo Kim
arXiv:2507. 12645v1 Announce Type: cross Abstract: The increasing need for accurate and unified analysis of diverse biological signals, such as ECG and EEG, is paramount for comprehensive patient assessment, especially in synchronous monitoring.
By Mohammed Guhdar, Ramadhan J. Mstafa, Abdulhakeem O. Mohammed
The paper presents a compact underwater acoustic classification framework that integrates multi-representation feature engineering, temporal statistical pooling, and lightweight convolutional architectures for acoustic time-frequency and cochlear representations. Experiments on the ShipsEar dataset show a two-layer CNN achieving a macro F1 of 0.9918 and an RBF-SVM reaching 0.9883, but recording provenance issues limit verification of generalisation. When evaluated on the DeepShip dataset with recording-level partitioning, a 157K-parameter CNN attains a macro F1 of 0.7226, while a larger ResNet18 does not improve validation performance, underscoring the need for representation-aware design and rigorous evaluation for deployable systems.
By Abishek Soti, Thura Pyae Sone, Naqib Ibnul, Htoo Htet Aung, Henry Zhong, Gregory Cohen, Ying Xu
arXiv:2606. 19888v1 Announce Type: cross Abstract: Modeling long-sequence medical time series data, such as electrocardiograms (ECG), poses significant challenges due to high sampling rates, multichannel signal complexity, inherent noise, and limited labeled data.
By Feng Wu, Harsh Deep, Eric Lehman, Sanyam Kapoor, Guoshuai Zhao, Rahul Krishnan, Gari Clifford, Li-wei H Lehman