The study evaluates how acquisition context and photoplethysmography (PPG) signals contribute to session‑calibrated blood pressure tracking using a wearable‑state model on 653 AuroraBP participants. Adding contextual information reduced mean absolute errors (MAEs) for systolic and diastolic BP by 0.436 mmHg and 0.126 mmHg, respectively, while PPG alone provided modest improvements. Exploratory follow‑ups with sensor‑history ensembles and pulse‑rate fusion yielded only slight gains, and a separate intraoperative model (VitalDB) showed limited PPG benefit.
By Farouk Ganiyu Adewumi, Timothy Oladunni
arXiv:2606. 11125v1 Announce Type: cross Abstract: Blood pressure (BP) is a key marker for cardiovascular risk assessment and therapeutic decision-making, and Photoplethysmography (PPG) enables low-cost, wearable-friendly cuffless BP estimation.
By Yidan Shen, Neville Mathew, Maham Rahimi, Deependra Dhakal, George Zouridakis, Xin Fu, Renjie Hu
The paper presents a hybrid Transformer framework that estimates non‑invasive continuous blood pressure from ECG/PPG‑derived feature sequences. It models 10‑step sequences of six physiological descriptors and two demographic covariates, combining Transformer, Kolmogorov‑Arnold Network, and XGBoost modules, and uses a dynamic fusion decoder to predict diastolic and systolic BP. On a large MIMIC‑III dataset, the model achieved mean errors of 0.41 mmHg (diastolic) and –1.60 mmHg (systolic) with high accuracy within 10 mmHg for most predictions.
By Yuexin Ma, Jingqi Hou, Yuxuan Kang, Zhaoying Liu
arXiv:2607. 23406v1 Announce Type: cross Abstract: Continuous cuffless blood pressure (BP) monitoring is essential for connected health systems and wearable devices, enabling early detection, longitudinal tracking, and personalized management of cardiovascular disease.
By Bo Wu, Haoling Wang, Zhuodiao Kuang, Kateryna Shapovalenko
SIFPBPNet is a dual‑path neural network designed for cuffless blood‑pressure estimation from photoplethysmography (PPG) signals. It separates steady‑state and instantaneous features through a Steady‑state Feature Path (SFP) that uses a Graph Attention Network to learn individual‑specific long‑term patterns, and an Instantaneous Feature Path (IFP) that captures short‑term dynamics and fuses them with the steady‑state prior via cross‑attention. On a large wearable dataset, the model achieves mean absolute errors of 8.57 mmHg for systolic and 5.97 mmHg for diastolic BP, outperforming existing methods and showing that the SFP module can be added to other backbones for 2.8–13.1 % MAE reduction.
By Shuailong Tang, Xiaoyu Li, Donglin Xie, Wei Chen, Guangpu Zhu, Yelei Li, Yali Zheng
The paper introduces a fluctuation‑aware evaluation framework for photoplethysmography (PPG)‑based blood pressure (BP) estimation that uses time‑series change‑point detection to identify abrupt BP shifts, rather than relying on simple BP thresholds. It demonstrates that many state‑of‑the‑art models degrade significantly around these change points and that periodic test‑time calibration is inadequate. To mitigate this, the authors propose a targeted re‑calibration strategy triggered by detected change points, improving robustness without altering model architectures.