Occupancy Network-Guided Autonomous Robotic Partial Nephrectomy
Read the original on arXiv Computer Vision →The Flow has not summarised this story yet — read it at arXiv Computer Vision.
The Flow has not summarised this story yet — read it at arXiv Computer Vision.
The paper introduces an automated 3D segmentation pipeline for prostate surgical phantoms derived from CT scans, leveraging classical image‑processing techniques and anatomical priors to avoid the need for training data. The method achieves a median Dice score of 0.83 on 11 contrast‑suppressed scans and correctly identifies all 32 annotated focal lesions, processing a full scan in 2–8 minutes on standard CPU hardware compared to 1–2 hours manually. This approach enables rapid, consistent phantom model iteration for robotic surgery research.
arXiv:2604. 21017v3 Announce Type: replace-cross Abstract: Autonomous medical robots hold promise to improve patient outcomes, reduce provider workload, democratize access to care, and enable superhuman precision.
The paper introduces a fully automated, calibration‑free pipeline that generates a 3D hyperspectral point cloud of ex‑vivo lumpectomy specimens using consumer‑camera RGB images and a single top‑down HSI acquisition. The 3D geometry is reconstructed via a deep‑learning Structure‑from‑Motion backbone, refined with a custom bundle adjustment that aligns ArUco marker corners, and the HSI cube is registered through planar homographies defined by these markers. On two specimens, the method achieves median 3D registration errors below 1 mm and 2D reprojection errors under 0.02 mm, completing processing in under 4 minutes on accelerated hardware.
arXiv:2607. 13475v1 Announce Type: cross Abstract: Surgical tissue retraction requires effective manipulation planning under partial and noisy perception.
LapaTrack-3D is a real‑time 6 DoF tracking algorithm designed for monocular laparoscopic surgery, aligning intra‑operative video with pre‑operative CT data. It modifies the ORB‑SLAM2 framework with four key changes: fast initialization using a primitive 3D shape, a pseudo‑segmentation strategy to isolate the target organ, incorporation of the 3D shape as a geometric prior in pose graph optimization, and enhanced imaging via a modified Multi‑Scale Retinex with Chromaticity Preservation algorithm. Experiments on in‑vivo and ex‑vivo data show robust tracking under challenging conditions such as poor illumination, fast motion, and partial visibility, achieving 13 Hz on 1280×720 video.
arXiv:2608. 06770v1 Announce Type: new Abstract: Controllable surgical world models can provide a generative foundation for surgical artificial intelligence and simulation by synthesizing realistic instrument--tissue interactions.