C3VDReg is a benchmark for local-to-local colonoscopic registration that uses the Colonoscopy 3D Video Dataset (C3VD) to generate 10,015 partial-to-partial point cloud pairs, with 2,088 held‑out test pairs. Each pair consists of a source point cloud from depth reprojection and a target point cloud from CT mesh raycasting, evaluated under a standardized protocol of 8,192 points per cloud and fixed pose conventions. Experiments show that high geometric overlap does not guarantee reliable pose recovery, revealing translation ambiguity along repetitive tubular anatomy as a key failure mode.
By Linzhe Jiang, Jiayuan Huang, Sophia Bano, Matthew J. Clarkson, Zhehua Mao, Mobarak I. Hoque
arXiv:2609.23961v1 Announce Type: new
Abstract: Monocular colonoscopic 3D reconstruction is important for surgical robotic colonoscopy, but remains challenging due to weak texture, specular reflectio...
By Zhihao Xing, Yingyu Wang, Liang Zhao, Shoudong Huang
The paper presents a clinically viable pipeline that uses routine intraoperative C‑arm fluoroscopy to derive per‑vertebra 6‑DoF poses, which are co‑registered to an RGB‑D camera via a multimodal fiducial array. This approach provides independent subsurface ground truth for validating markerless spinal tracking methods without adding radiation or altering standard surgical workflows. Ex vivo tests show an end‑to‑end accuracy of about 2 mm and 3.3°, and the framework is applied to evaluate two markerless registration strategies on real surgical data.
By Connor Daly, Salvatore Russo, Jinendra Ekanayake, Daniel S. Elson, Ferdinando Rodriguez y Baena
Monocular colonoscopic 3D reconstruction is important for surgical robotic colonoscopy, but remains challenging due to weak texture, specular reflections, limited view overlap, and non-rigid tissue mo...
Positive margins in head and neck oncologic surgery require mapping specimen-side pathology findings to the patient resection bed. This is challenging because pathologists identify the positive margin on slices of the resected, deformed specimen, while surgeons must relocate the corresponding site on the resection bed using only verbal descriptions and no visual guidance.
LapaTrack-3D is a real‑time 6 DoF tracking algorithm designed for monocular laparoscopic surgery, aligning intra‑operative video with pre‑operative CT data. It modifies the ORB‑SLAM2 framework with four key changes: fast initialization using a primitive 3D shape, a pseudo‑segmentation strategy to isolate the target organ, incorporation of the 3D shape as a geometric prior in pose graph optimization, and enhanced imaging via a modified Multi‑Scale Retinex with Chromaticity Preservation algorithm. Experiments on in‑vivo and ex‑vivo data show robust tracking under challenging conditions such as poor illumination, fast motion, and partial visibility, achieving 13 Hz on 1280×720 video.
By Jingwei Song, Javid Hussain Jakir, Ray Zhang, Wenwei Zhang, Hao Zhou, Xiaomeng Xian, Maani Ghaffari