arXiv AI By Md. Sadibul Hasan Sadib, Md. Mohayminul Mukit, Rahmatul Kabir Rasel Sarker, Tahmid Alam Tamim, Md. Nazmul Hasan, Md. Monir Hossain Shimul

Calibrated selective prediction using deep ensembles for thyroid nodule ultrasound classification under dataset shift

Read the original on arXiv AI →

The study presents a calibrated deep‑ensemble model for classifying thyroid nodules on ultrasound, employing uncertainty‑aware selective prediction and conservative triage. Using nested cross‑validation on the TN5000 dataset, the model achieved high discrimination (AUC‑ROC 0.9377) and strong calibration (ECE 0.0138), while a risk‑coverage analysis guided 8.86% of cases to no FNA, 60% to FNA, and 31% to radiologist review. When applied to the TN3K dataset without recalibration, performance dropped markedly (AUC‑ROC 0.7870, ECE 0.1899), highlighting limited transportability under dataset shift.

Machine-generated by The Flow from the publisher's headline and feed description — not written or checked by a human. The full article lives at arXiv AI.

arXiv AI
Jul 15

Calibrated Selective Prediction Using Deep Ensembles for ROI-Based Thyroid Nodule Ultrasound Classification Under Dataset Shift: A Retrospective Evaluation

arXiv:2607. 12075v1 Announce Type: cross Abstract: Background: Deep learning models can classify thyroid nodules on ultrasound, but reliable clinical decision support also requires calibrated probabilities, uncertainty estimation, and selective referral, particularly under dataset shift.

By Md. Sadibul Hasan Sadib, Md. Mohayminul Mukit, Rahmatul Kabir Rasel Sarker, Tahmid Alam Tamim, Md. Monir Hossain Shimul
arXiv Computer Vision
Oct 12

Radiomics-Based Thyroid Nodule Classification with Label-Conditional Conformal Prediction

The paper presents a radiomics-based approach for classifying thyroid nodules using ultrasound images. It extracts quantitative features with PyRadiomics and employs a Generalized Additive Model (GAM) chosen for its balance of performance and interpretability, achieving an AUC of 0.89, sensitivity of 0.83, and specificity of 0.82 on a public dataset. To provide uncertainty estimates, Cross-Conformal Prediction with label-conditional guarantees is applied, allowing 63% of test nodules to receive a confident single-label prediction while the remaining 37% are referred to clinicians.

By Laura Testa, Pierpaolo Brutti, Umberto Ferraro Petrillo
arXiv Computer Vision
Nov 9

Deep-Learning Algorithm for Indeterminate Thyroid Nodules: Comparison and Combination with Molecular Testing

The study evaluated a convolutional neural network (CNN) trained on routine ultrasound images to stratify Bethesda III thyroid nodules with indeterminate cytology, comparing its performance to molecular testing (Afirma or ThyroSeq). In a test set of 47 nodules, the CNN achieved an AUC of 0.73 versus 0.55 for molecular testing, showing higher specificity (0.95 vs 0.32) and positive predictive value (0.67 vs 0.21) but lower sensitivity. The DL model further subdivided molecular‑positive nodules into high‑risk (4/6 malignant) and lower‑risk (3/27 malignant) groups, suggesting ultrasound deep learning can complement molecular testing by identifying lower‑risk cases.

By Jichen Yang, Jeffrey Ashton, Jikai Zhang, Maciej A. Mazurowski, Benjamin Wildman-Tobriner
arXiv Computer Vision
Oct 12

Thyroid Nodule Segmentation in Ultrasound Images with Conformal Uncertainty Estimation

The paper presents a thyroid nodule segmentation framework for ultrasound images that combines DeepLabV3+ with EfficientNet‑B5, channel‑attention modules (Squeeze‑and‑Excitation, CBAM, GCA), and a post‑hoc conformal prediction layer to provide pixel‑level uncertainty estimates. Experiments on the TN3K benchmark show that the CBAM‑augmented model with Dice‑BCE loss outperforms existing methods. The approach aims to improve the first stage of a CAD pipeline for malignancy classification and metastatic risk assessment.

By Francesco Teodori, Pierpaolo Brutti, Umberto Ferraro Petrillo