arXiv:2607. 12075v1 Announce Type: cross Abstract: Background: Deep learning models can classify thyroid nodules on ultrasound, but reliable clinical decision support also requires calibrated probabilities, uncertainty estimation, and selective referral, particularly under dataset shift.
By Md. Sadibul Hasan Sadib, Md. Mohayminul Mukit, Rahmatul Kabir Rasel Sarker, Tahmid Alam Tamim, Md. Monir Hossain Shimul
The study presents a calibrated deep‑ensemble model for classifying thyroid nodules on ultrasound, employing uncertainty‑aware selective prediction and conservative triage. Using nested cross‑validation on the TN5000 dataset, the model achieved high discrimination (AUC‑ROC 0.9377) and strong calibration (ECE 0.0138), while a risk‑coverage analysis guided 8.86% of cases to no FNA, 60% to FNA, and 31% to radiologist review. When applied to the TN3K dataset without recalibration, performance dropped markedly (AUC‑ROC 0.7870, ECE 0.1899), highlighting limited transportability under dataset shift.
By Md. Sadibul Hasan Sadib, Md. Mohayminul Mukit, Rahmatul Kabir Rasel Sarker, Tahmid Alam Tamim, Md. Nazmul Hasan, Md. Monir Hossain Shimul
The study compares 2D, 2.5D, and 3D residual networks for classifying pulmonary nodule malignancy risk using a retrospective LIDC‑IDRI cohort of 2,654 nodules. Models were trained with random initialization, momentum‑contrast pretraining, and mild data augmentation, and evaluated on patient‑disjoint splits. Augmented 2.5D models achieved the highest test Macro‑F1 (0.6537) and accuracy (0.6869), while 2D and 3D models performed lower, and pretraining generally reduced performance.
By Bahodir Nazarov, Zineb Gharib, Fatima Zazoul
Purpose: To compare 2D, 2.5D, and 3D residual networks for pulmonary nodule malignancy-risk classification and evaluate momentum-contrast pretraining, mild augmentation, and exclusion of indeterminate...
The paper presents a thyroid nodule segmentation framework for ultrasound images that combines DeepLabV3+ with EfficientNet‑B5, channel‑attention modules (Squeeze‑and‑Excitation, CBAM, GCA), and a post‑hoc conformal prediction layer to provide pixel‑level uncertainty estimates. Experiments on the TN3K benchmark show that the CBAM‑augmented model with Dice‑BCE loss outperforms existing methods. The approach aims to improve the first stage of a CAD pipeline for malignancy classification and metastatic risk assessment.
By Francesco Teodori, Pierpaolo Brutti, Umberto Ferraro Petrillo
TAM-Chain is a multi‑scale thyroid cytology classification framework that uses Absorbing Markov Chains and Shannon Entropy to quantify uncertainty and dynamically decide when to stop processing and refer to a specialist. It processes images at 10×, 20×, and 40× magnifications, achieving a Macro F1 score of 0.9741 on an internal test set with a 0 % false‑negative rate, and maintains a Macro F1 of 0.7026 on an external validation set with severe domain shift. The method outperforms single‑magnification baselines by adaptively adjusting stopping steps and triggering specialist referrals, thereby reducing critical diagnostic errors.
By Hai Pham Ngoc