Comparison of techniques for fine-tuning open-weight models for entity extraction from radiology reports
Read the original on Hugging Face Trending Papers →The Flow has not summarised this story yet — read it at Hugging Face Trending Papers.
The Flow has not summarised this story yet — read it at Hugging Face Trending Papers.
The study evaluates whether a fine‑tuned open‑weight model (Gemma‑3‑12B) can match the performance of GPT‑4o in extracting multi‑label intracranial hemorrhage acuity from non‑contrast head‑CT reports. Using a 2×2 design that varied adaptation strategy (classification head vs. instruction fine‑tuning) and training‑data source (distilled real GPT‑4o labels vs. synthetic GPT‑4o‑generated reports), the distilled instruction‑tuned model achieved macro‑F1 scores comparable to GPT‑4o and surpassed the untuned base model. The key finding is that the source of training data—distilled real reports—was more important than the fine‑tuning method, and that the entire fine‑tuning and inference process fits on a single 24 GB consumer GPU.
arXiv:2607. 14205v1 Announce Type: new Abstract: Federated learning (FL) enables multi-institutional training on clinical text without sharing raw data, but gradient inversion can reconstruct sensitive information from shared model updates.
Medical vision-language models (VLMs) capture cross-modal relationships between image and text, yet their adaptation to institution-specific clinical tasks remains underexplored. In this study, we fin...
arXiv:2607. 05880v1 Announce Type: cross Abstract: Imaging demand is growing faster than the radiology workforce can expand, and reporting backlogs cannot be resolved through training and recruitment alone.
The study fine‑tunes a pretrained 3D medical vision‑language model for hepatocellular carcinoma (HCC) classification using paired abdominal CT scans and radiology reports from a different institution. Two adaptation strategies—full fine‑tuning and parameter‑efficient fine‑tuning (PEFT)—both achieve strong performance (AUC 0.82/0.79, F1 0.71/0.70) despite cross‑institutional domain shift, with PEFT updating only ~1% of parameters. The work highlights the trade‑offs between rapid convergence and overfitting in full fine‑tuning versus the efficiency of PEFT, and shows that self‑supervised CT‑report contrastive learning can improve HCC classification without lesion‑level annotations.
The paper evaluates large language model (LLM) judges for radiology report assessment across multiple imaging modalities and anatomical regions, comparing four existing metrics (RadFact, GREEN, FineRadScore, CRIMSON) with a new metric called VERT. GREEN emerges as the most robust among current metrics, while VERT improves correlation with radiologist judgments by up to 26% over GREEN. The study also shows that ensembling and lightweight fine‑tuning of the Qwen3‑30B model can yield additional performance gains and significant latency reductions.