Converting free-text radiology reports into structured labels supports cohort building, quality assurance, and monitoring of clinical imaging models, but the strongest label extractors are hosted prop...
arXiv:2607. 14205v1 Announce Type: new Abstract: Federated learning (FL) enables multi-institutional training on clinical text without sharing raw data, but gradient inversion can reconstruct sensitive information from shared model updates.
By Santhosh Parampottupadam, Andres Martinez, Dimitrios Bounias, Sinem Sav, Klaus Maier-Hein, Ralf Floca
arXiv:2607. 05880v1 Announce Type: cross Abstract: Imaging demand is growing faster than the radiology workforce can expand, and reporting backlogs cannot be resolved through training and recruitment alone.
By Suneeta Mall, Vladimir Nekrasov, Ashnil Kumar, Sajith Karunasena, Aiden Nibali, Alix Bird, Mateo Diaz Shine, Jarrel Seah
The study audits a class‑imbalance benchmarking protocol for multimodal chest X‑ray and EHR prediction using 29,083 MIMIC‑CXR images from 10,479 patients. It finds that record‑level splits create leakage: a simple lookup table can match the best model, and when evaluated on unseen patients all models collapse to predicting every case positive. After correcting for patient‑separated evaluation and refined labels, no imbalance strategy improves macro F2 beyond 0.01, tuned tree ensembles offer no advantage over logistic regression, and EHR variables alone remain at an all‑positive baseline, while image embeddings and diagnostic history provide the strongest signals.
By Dang-Khoa Bui, Quang-Huy Tran, Minh-Khoi Nguyen-Bui, Duc-Tuan Ngo, Thanh-Trong Tran, Tuan-Khoi Nguyen, Hoang-Anh Ngo
arXiv:2608.30021v1 Announce Type: cross
Abstract: Errors in radiology reports can adversely affect patient treatment, yet automated report quality assurance remains challenging because errors are oft...
By Hermione Warr, Harry Anthony, Lilli J Freischem, Yasin Ibrahim, Daniel R McGowan, Konstantinos Kamnitsas
The paper evaluates large language model (LLM) judges for radiology report assessment across multiple imaging modalities and anatomical regions, comparing four existing metrics (RadFact, GREEN, FineRadScore, CRIMSON) with a new metric called VERT. GREEN emerges as the most robust among current metrics, while VERT improves correlation with radiologist judgments by up to 26% over GREEN. The study also shows that ensembling and lightweight fine‑tuning of the Qwen3‑30B model can yield additional performance gains and significant latency reductions.
By Federica Bologna, Jean-Philippe Corbeil, Matthew Wilkens, Asma Ben Abacha