AtlasPatch: Scalable Foundation Model-based Tissue Detection and Patch Extraction for Computational Pathology
Read the original on arXiv Computer Vision →The Flow has not summarised this story yet — read it at arXiv Computer Vision.
The Flow has not summarised this story yet — read it at arXiv Computer Vision.
Whole slide images (WSIs) in digital histopathology are acquired at discrete magnification levels encoding complementary diagnostic information from global tissue architecture to fine-grained cellular morphology. Yet, deep learning models remain sensitive to scale variation.
arXiv:2609.00396v1 Announce Type: new Abstract: Histopathological whole slide images (WSIs) are central to cancer diagnosis, but their gigapixel scale, tissue heterogeneity, weak slide-level supervis...
LanGuSTE is a patch‑selection framework for whole slide image analysis that uses vision‑language models and large language model knowledge. It introduces Cross‑Scale Visual Prompt Tuning to align low‑resolution and high‑resolution patches, and a coarse‑to‑fine selection module that encodes only informative high‑resolution patches. Experiments show LanGuSTE cuts overall processing time to about one‑third of the baseline while matching or surpassing diagnostic performance of exhaustive and state‑of‑the‑art methods.
The paper introduces Segment Anything Small (SAS), a data‑augmentation method that improves deep‑learning segmentation of small anatomical structures in ultrasound images. SAS uses two transformations: resizing and embedding organ thumbnails into a black background to vary organ scale, and adding noise to regions of interest to mimic tissue texture variability. Experiments on one internal and five external datasets show Dice score gains up to 0.35, with an average improvement of 0.16, and demonstrate that SAS enhances model robustness and generalizability without adding hallucinations or artifacts.
arXiv:2606. 06864v1 Announce Type: cross Abstract: Multiple instance learning (MIL) has become a standard paradigm for whole slide image (WSI) analysis in digital pathology, as it enables slide-level prediction without dense annotations.
arXiv:2602. 21987v3 Announce Type: replace-cross Abstract: Low-dose CT images are essential for reducing radiation exposure in cancer screening, pediatric imaging, and longitudinal monitoring protocols, but their quality is often degraded by noise from low-dose acquisition, patient motion, or scanner limitations, affecting both clinical interpretation and downstream analysis.