The paper introduces a decision‑aware evaluation protocol for medical image segmentation uncertainty that separates uncertainty estimation from deferral policy and assesses their joint performance under fixed review budgets. It reports metrics such as fixed‑budget error reduction, risk‑coverage behavior, region‑level review proxies, structural failure modes, and sensitivity to review assumptions. Experiments on retinal vessel, skin lesion, and polyp segmentation with various backbones and uncertainty estimators show that estimator rankings vary with review unit, uncertainty target, and cost model, and that boundary and thin‑structure failures are partly due to annotation ambiguity.
By Saket Maganti, Shreyank N Gowda
arXiv:2611.22380v1 Announce Type: cross
Abstract: We propose a self-configuring framework that extends the nnU-Net workflow to both segmentation and classification in 3D medical imaging. Building on...
By Renjun Cai, Antonio Javier Gallego, F\'elix Fuentes-Hurtado
arXiv:2604.12411v2 Announce Type: replace
Abstract: Segmentation models based on deep neural networks demonstrate strong generalization for medical image segmentation. However, they often exhibit ove...
By Qiuyu Tian, Haoliang Sun, Yunshan Wang, Yinghuan Shi, Yilong Yin
arXiv:2608.29677v1 Announce Type: cross
Abstract: Despite rapid advances in MIS, fair and reproducible comparisons of segmentation models remain challenging due to heterogeneous datasets, inconsisten...
By Vanessa Borst, Lukas Horn, Daniel Grillmeyer, Thomas Prantl, Samuel Kounev
arXiv:2608. 13711v1 Announce Type: cross Abstract: Computer-aided detection (CADe) systems for colonoscopy promise to reduce clinical miss rates, yet reliable real-world deployment remains elusive.
By Sebastian Doerrich, Andreas Franz Schwab, Francesco Di Salvo, Shyam Nandan Rai, Hanh Huyen My Nguyen, Christian Ledig
The paper introduces BiCC, a bidirectional connected-component loss that pairs annotation- and prediction-derived partitions to score predicted components on their own scale. By deriving instances from predictions, BiCC directly penalizes false-positive components regardless of size, allowing a balance parameter to control the lesion-wise precision–recall trade-off. Across five datasets, BiCC outperforms existing instance-aware losses such as CC-DiceCE and blob loss in lesion-wise F1, and improves over DiceCE on multiple datasets.
By Luc Bouteille, Frederic Jonske, Jens Kleesiek, Alexander Jaus
arXiv:2610.17573v1 Announce Type: cross
Abstract: Self-supervised pretraining has expanded the pool of 3D medical foundation models, but published evaluations use different datasets, endpoints and fi...
By Jiaqi Tang, Yu Wang, Yang Liu, Jing Tao, Fandong Zhang, Zhou Zhen, Xiahai Zhuang, Qingchao Chen, Yining Yang, Yizhou Yu
The paper introduces CARDIAG, a multi‑center benchmark dataset for fine‑grained SYNTAX segmentation of coronary angiograms, featuring highly imbalanced multi‑class labels, catheter and stenosis masks, expert uncertainty maps, temporal frames, and spatial metadata. The authors conduct an extensive architectural sweep of 24 models—including CNNs, Vision Transformers, and State‑Space Models—using advanced metrics such as clDice, vessel diameter error, and uncertainty error‑detection. Their findings show that large‑kernel CNNs (ConvNeXt V2 with DeepLabV3+) outperform recent ViTs and SSMs, achieving a Dice score of 0.456, which improves to 0.479 with model ensembling, while also exploring out‑of‑distribution generalization through leave‑one‑center‑out cross‑validation.
By Dominik Bernard Lau, Jerzy Szyjut, Hubert Malinowski, Adam Brzeski, Tomasz Dziubich, Natalia Zieli\'nska, Tomasz Figatowski, Rados{\l}aw Targo\'nski
arXiv:2607. 06254v1 Announce Type: cross Abstract: Deepfake image detection is currently served by three fundamentally different paradigms: commercial APIs, zero-shot vision-language models (LLMs), and open-source detectors.
By Sharayu N. Deshmukh, Md Rashidunnabi, Nelton Tiago Gemo, Kurundkar G. D., Mahamune M. R., Nilesh K. Deshmukh
The paper presents a two‑stage approach to street‑panorama semantic segmentation using Vision Transformer ensembles. In the first stage, nine pretrained models are compared under equal compute budgets, and the best two are trained with three random seeds, achieving 60.95% mIoU on validation and 57.08% on the hidden test leaderboard. The second stage explores augmentations, larger inputs, and additional architectures, culminating in an ensemble of four models that scores 64.53% mIoU on validation and 61.54% mIoU (71.93% F1) on the hidden test leaderboard, while the study documents all runs, costs, and releases the code and models.
By Yunus Serhat B{\i}\c{c}ak\c{c}{\i}
arXiv:2609.25850v1 Announce Type: new
Abstract: Deep learning performance generally improves with increasing training data, yet this scaling is fundamentally constrained by annotation cost in large-s...
By Xiaofei Du, Lei Zhang, Shuyu Yan, Manning Wang, Zhijian Song
arXiv:2603.13044v2 Announce Type: replace-cross
Abstract: Medical image segmentation (MIS) is a fundamental component of computer-assisted diagnosis and clinical decision support. Over the past decad...
By Vanessa Borst, Anna Riedmann, Samuel Kounev