Leveraging Segmentation Representations for Efficient Classification: A Self-Configuring Framework Based on nnU-Net
Read the original on arXiv AI →The Flow has not summarised this story yet — read it at arXiv AI.
The Flow has not summarised this story yet — read it at arXiv AI.
arXiv:2610.17573v1 Announce Type: cross Abstract: Self-supervised pretraining has expanded the pool of 3D medical foundation models, but published evaluations use different datasets, endpoints and fi...
arXiv:2609.25850v1 Announce Type: new Abstract: Deep learning performance generally improves with increasing training data, yet this scaling is fundamentally constrained by annotation cost in large-s...
MTMed3D is a multi-task Transformer-based model that jointly performs 3D detection, segmentation, and classification in medical imaging. It uses a shared Transformer encoder to produce multi-scale features, with separate CNN decoders for each task. Evaluated on BraTS 2018 and 2019, it achieves strong results, especially in detection, while reducing computational cost and inference time compared to single-task models.
The paper presents a lightweight, energy‑efficient lung tumor segmentation model that combines the ENet architecture with UNet‑style skip connections and a lightweight Convolutional Block Attention Module (CBAM). Trained on TCIA data and evaluated on LIDC‑IDRI, the model achieves a Dice score of 0.90812 while using only 430,052 parameters and 0.549 GMAC, making it up to 10 times faster and far less computationally demanding than UNet or SegNet. Grad‑CAM is employed to provide visual interpretability and highlight areas needing improvement.
The paper presents a two‑pipeline framework for retinal fundus analysis that combines four‑class disease classification with vessel segmentation. It fine‑tunes eight ImageNet‑pretrained CNNs on the FIVES dataset, applies five gradient‑based explanation methods to assess model interpretability, and benchmarks ten U‑Net variants—including transformer‑based and attention‑enhanced architectures—on the FIVES and DRIVE datasets. The best classification results come from ResNet101 (94.17% accuracy), while the strongest segmentation performance is achieved by Attention U‑Net with a ResNet101V2 backbone, improving DRIVE IoU from 60.80% to 64.83%.
arXiv:2608.23745v1 Announce Type: cross Abstract: Accurate brain tumor segmentation from magnetic resonance imaging (MRI) is essential for diagnosis, treatment planning, surgical guidance, and diseas...