The study examines how LoRA adaptation of four Vision Foundation Models—DINOv3, SigLIP2, MerMED-FM, and BiomedCLIP—affects brain MRI tasks. Despite achieving similar segmentation accuracy (mean Dice 78‑81%), the models exhibit distinct internal dynamics, with early‑to‑mid layers being most crucial for segmentation. Restricting LoRA to these layers yields comparable performance while mitigating negative impacts on Alzheimer’s disease classification.
By Cecilia Diana-Albelda, Fiona Kekwick, Raghav Mehta, Aleksandra Kulbaka, Paul M. Matthews, Jesus Bescos, \'Alvaro Garc\'ia-Mart\'in, Wenjia Bai, Bernhard Kainz
arXiv:2610.34884v1 Announce Type: new
Abstract: Reusing pretrained medical-imaging models offers an alternative to training from scratch. A model trained for the same task may perform poorly at a new...
By Hanxue Gu, Zhonghao Liu, Xingrui Gu, Kang Wang, Yang Yang
The paper introduces two lightweight spectral adapters—Directional Spectral Adapter (DiSECT) and Spectral Instance-Guided Adapter (SiGA)—to adapt the Segment Anything Model (SAM) for accurate segmentation of colorectal liver metastases in contrast‑enhanced CT scans. SiGA achieves the highest single‑point Dice score of 0.77 and performs comparably to a 3D nnU‑Net baseline under no‑prompt inference, while DiSECT requires only 0.14 million trainable parameters. The study evaluates the adapters on 446 CT volumes across various prompting regimes, demonstrating that spectral adapters can efficiently adapt SAM with limited trainable parameters while maintaining strong segmentation accuracy.
By Ramtin Mojtahedi, Mohammad Hamghalam, Jacob J. Peoples, Natalie Gangai, Mithat Gonen, Yun Shin Chun, HyunSeon Christine Kang, Richard K. G. Do, Amber L. Simpson
arXiv:2609.14106v1 Announce Type: new
Abstract: We evaluated parameter-efficient fine-tuning (PEFT) of the Segment Anything Model (SAM) for liver tumor segmentation in abdominal CT of colorectal live...
By Ramtin Mojtahedi, Mohammad Hamghalam, Jacob J. Peoples, Richard K. G. Do, Amber L. Simpson
arXiv:2608. 07749v1 Announce Type: cross Abstract: Parameter-efficient fine-tuning enables the adaptation of vision foundation models to biomedical tasks under limited computational resources, but a single low-rank update can constrain all task-specific changes to one narrow parameter subspace.
By Saed Moradi, Benyamin Ghojogh, M. Hadi Sepanj, Yimin Yang, Ashirbani Saha
arXiv:2606. 01947v1 Announce Type: cross Abstract: Research and applications in artificial intelligence have recently shifted with the rise of large pretrained models, which deliver state-of-the-art results across numerous tasks.
By Nermeen Abou Baker, David Rohrschneider, Uwe Handmann
The study investigates how few expert-annotated cases are needed to fine‑tune MedSAM3 for abdominal organ segmentation using Low‑Rank Adaptation (LoRA). With only 10 annotated CT or MRI cases, the LoRA‑adapted models achieve performance comparable to specialist systems that require orders of magnitude more data, including reliable gallbladder segmentation and near‑state‑of‑the‑art results for liver, kidneys, and spleen. The approach also generalizes to cardiac segmentation on the Whole Heart dataset, and training takes only 3–5 hours per organ on a single GPU, roughly twice as fast as nnU-Net.
By Sachin Dudda Nagaraju, Bendik Skarre Abrahamsen, Ashkan Moradi, Mattijs Elschot
arXiv:2606. 10196v1 Announce Type: cross Abstract: Parameter-efficient fine-tuning (PEFT) aims to adapt pretrained models with a small trainable parameter subset, however, most existing methods choose this subset from fixed architectural heuristics rather than using dynamic, task-aware criteria.
By Ghodsiyeh Rostami, Po-Han Chen, Mahdi S. Hosseini
arXiv:2608.21300v1 Announce Type: new
Abstract: Foundation models for medical image segmentation, like prompt-based MedSAM, generalize well across domains and modalities, often in zero or few-shot se...
By Marko Haralovi\'c, Sounic Akkaraju, Carlo Baretta, Vasil Zapryanov, Alexia Briassouli
arXiv:2607. 16888v1 Announce Type: cross Abstract: Deploying a medical imaging model that must later accommodate a modality it has never seen is a recurring practical problem: retraining the shared representation is expensive and destroys performance on the modalities already in service.
By Ranat Das Prangon, Istiaque Ahmed, Shajid Hasan Naim, Waseem Mustak Zisan, Hossain Md Shakhawat
arXiv:2609.21412v1 Announce Type: new
Abstract: Medical image segmenters often get worse when sites, scanner vendors, or protocols change. Continual test-time adaptation (CTTA) addresses this problem...
By Ruijie Huang
arXiv:2505. 18315v3 Announce Type: replace-cross Abstract: We introduce \textbf{CoLoRA} (Convolutional Low-Rank Adaptation), a parameter-efficient fine-tuning method for convolutional neural networks (CNNs).
By Mariano Rivera, Angello Hoyos