arXiv:2606. 23707v1 Announce Type: cross Abstract: EEG spatial super-resolution (EEGSR) in real deployments is challenged by random channel missingness, unstable electrode quality, and changing visible-channel patterns caused by bad contacts or device variability.
By Hongjun Liu, Leyu Zhou, Zijianghao Yang, Chao Yao
arXiv:2608. 00048v1 Announce Type: cross Abstract: Electroencephalography (EEG) generation is essential for alleviating data scarcity and enabling large scale neural modeling in brain computer interface applications.
By Boheng Liu, Ziyu Li, Chenghua Duan, Qing Li, Xia Wu
arXiv:2607. 11530v1 Announce Type: new Abstract: Decoding continuous three-dimensional (3D) motor imagery (MI) using non-invasive electroencephalography (EEG)-based brain--computer interfaces (BCIs) remains challenging due to signal variability and residual decoding errors.
By Jiamian Li, Niall McShane, Attila Korik, Naomi du Bois, Karl McCreadie, Leen Jabban, Benjamin Metcalfe, \"Ozg\"ur \c{S}im\c{s}ek, Damien Coyle
The paper introduces TriDim, a reusable block that preserves the three EEG axes—channel, short‑term temporal, and long‑term temporal—by applying feed‑forward transformations and cross‑axis attention. Stacking these blocks yields TriDimEEG, a standalone EEG decoder that outperforms fifteen other models on eight datasets, achieving a 4.3% relative accuracy gain. Replacing Transformer blocks in existing EEG foundation models with TriDim blocks improves downstream accuracy by 7.4% on average while reducing parameters by 17.0% to 47.3%.
By Shiyue Su, Song Wang, Zekai Zhan, Junjie Zeng, Ziling Lu, Zongsheng Li, Xinyuan Ye, Zhiyuan Ma, Xinke Shen, Quanying Liu
arXiv:2605. 14941v2 Announce Type: replace-cross Abstract: Electroencephalogram (EEG) signals are highly susceptible to artifacts, resulting in a low signal-to-noise ratio, which makes extraction of meaningful neural information challenging.
By Shantanu Sarkar, Jose L. Contreras-Vidal
arXiv:2510. 15371v2 Announce Type: replace-cross Abstract: Classification of electroencephalogram (EEG) signals obtained during motor imagery (MI) has substantial application potential, including communication assistance and rehabilitation support for patients with motor impairments.
By Shuntaro Suzuki, Shunya Nagashima, Komei Sugiura
CortexBridge is a lightweight adapter that aligns arbitrary EEG electrode montages into a shared cortical latent space by combining EEG features with electrode and atlas coordinates. When evaluated on five BCI datasets from MOABB with three frozen foundation models, it improves performance in 13 of 15 tasks, achieving average balanced‑accuracy gains of 0.80% (EEGPT), 0.70% (LaBraM), and 3.26% (CBraMod), with a maximum 13.02% improvement on a 12‑class SSVEP task. Visualizations show task‑dependent spatial patterns, such as a concentrated representation in the Yeo Visual network for SSVEP versus auditory P300.
By Jiazhen Hong, Xiaotian Zhou, Zihao Ding, Kailong Wang, Yu Wu
arXiv:2606. 08594v1 Announce Type: new Abstract: Deep learning EEG denoising architectures have scaled from tens of thousands to tens of millions of parameters, yet no prior study has isolated model capacity as the experimental variable or tested whether reconstruction metrics predict downstream neural-signal utility.
By Jasmeet Singh Bindra, Siddharth Panwar, Shubhajit Roy Chowdhury
Decoding continuous three-dimensional (3D) motor imagery (MI) using non-invasive electroencephalography (EEG)-based brain--computer interfaces (BCIs) remains challenging due to signal variability and residual decoding errors. Deep learning architectures such as convolutional neural network--long short-term memory (CNN--LSTM) models can capture spatial and temporal dynamics for continuous kinematic decoding; however, systematic residual errors persist in predicted trajectories.
The paper introduces MOPC, a memory‑augmented online test‑time adaptation framework for EEG motor‑imagery BCIs that operates without source data. It uses random‑mask perturbations to enforce prediction consistency, a confidence‑calibrated reweighting loss to handle pseudolabels and class imbalance, and a lightweight memory module to prevent catastrophic forgetting. Evaluated on BCI IV IIb and OpenBMI datasets, MOPC outperforms prior methods by 2.22% and 3.67% while maintaining per‑trial adaptation latency of 40–60 ms.
By Kunkun Zhang, Kehao Wu, Zhitao Chen, Haigen Hu, Qianwei Zhou
arXiv:2609.13507v1 Announce Type: new
Abstract: Brain-computer interfaces (BCIs) decode neural activity to restore lost function. Typically, training a high-performance neural decoder requires a larg...
By Ben Tang, Zachary Spalding, Gregory B. Cogan
arXiv:2610.07420v1 Announce Type: new
Abstract: Electroencephalography (EEG) signals drift over time, which can cause static brain-computer interface (BCI) models to degrade in practice. We present a...
By Bogdan Kozyrskiy, Artem Grachev, Abraham I. Camelo Guerrero