arXiv Machine Learning

RAM-H1200: A Unified Evaluation and Dataset on Hand Radiographs for Rheumatoid Arthritis

RAM‑H1200 is a new public benchmark comprising 1,200 hand radiographs from six medical centers, each annotated with whole‑hand bone instance segmentation, pixel‑level bone erosion masks, joint regions of interest, and joint‑level Sharp‑van der Heijde (SvdH) scores for bone erosion and joint space narrowing. The dataset enables unified multi‑level analysis of anatomical structure, localized erosive pathology, and clinically standardized RA severity, filling a gap in existing resources that lack full‑hand coverage and fine‑grained annotations. Initial benchmark results show strong performance in bone segmentation but highlight that bone erosion segmentation remains a significant challenge, underscoring the dataset’s potential to advance quantitative RA analysis.

arXiv AI
Sep 10

Multiple Myeloma Lesion Segmentation on Whole-Body Diffusion-Weighted Imaging via Efficient Anatomical Anticipation and Multimodal Confirmation

arXiv:2609.06165v1 Announce Type: cross Abstract: Whole-body diffusion-weighted imaging (WB-DWI) is widely used for multiple myeloma (MM) assessment, yet automated lesion segmentation remains challen...

By Mengmeng Zhang, Shengqian Huang, Junde Zhou, Xiaoping Wu, Hao Luog, Jing Wanga, Yicheng Sun, Jiao Li, Haibo Zhang, Sheng Xie, Fan Wangg, Qin Wangc, Huadan Xue, Yisheng Lv, Fei-yue Wang
arXiv Computer Vision
Sep 25

Integrating Local Detail and Global Context: A Dual-Input Multi-Task Learning Framework for Bone Tumor Diagnosis

The paper introduces a dual‑input, multi‑task learning framework that jointly segments and classifies bone tumors by applying bidirectional cross‑modal attention between a lesion crop and the full radiograph. Using a YOLO‑based detector and a dual‑stream DenseNet121 architecture, the model fuses fine‑grained lesion detail with global anatomical context through a novel cross‑modal attention fusion strategy and hierarchical multi‑scale feature fusion. On the multi‑institutional Bone Tumor X‑ray Radiograph Dataset, the approach outperforms single‑input baselines, achieving a Dice coefficient of 0.896 and a macro‑averaged F1‑score of 0.928, with an AUC of 0.999 for malignant osteosarcoma.

By S. M. Nasif Uddin, Rusab Sarmun, Muhammad E. H. Chowdhury, Adam Mushtak, Israa Al-Hashimi, Sohaib Bassam Zoghoul
arXiv Computer Vision
Sep 10

SA-Profile: Automated Sulcus Angle Profiling from Super-Resolution MRI

arXiv:2609.10125v1 Announce Type: new Abstract: Trochlear dysplasia (TD) is an abnormality of the femoral trochlea associated with anterior knee pain and patellar instability. The sulcus angle (SA) i...

By Michael Wehrli, Leo Widmer, Edwin Li, Noel Fiechter, Lorenzo Pettinari, Sidaty El Hadramy, Carol C. Hasler, Philippe C. Cattin
arXiv AI
Jul 8

Harrison.Rad 1.5 Technical Report: A radiology foundation model that can draft reports from images, priors and clinical context

arXiv:2607. 05880v1 Announce Type: cross Abstract: Imaging demand is growing faster than the radiology workforce can expand, and reporting backlogs cannot be resolved through training and recruitment alone.

By Suneeta Mall, Vladimir Nekrasov, Ashnil Kumar, Sajith Karunasena, Aiden Nibali, Alix Bird, Mateo Diaz Shine, Jarrel Seah
arXiv AI
Aug 10

Measurements Automatically Extracted from Zero Echo Time MRI Using Deep Learning Image Segmentation and Geometric Modeling Agree with Expert Manual Readings

arXiv:2608. 07368v1 Announce Type: cross Abstract: Computed tomography (CT) remains the reference for 3D osseous morphometry in femoroacetabular impingement (FAI) but requires ionizing radiation and manual measurement.

By Jack Consolini, Eric A. Bogner, Meghan Sahr, Matthew F. Koff, Kevin M. Koch, Hollis G. Potter
arXiv Machine Learning
Sep 21

Detection is solved, delineation is not: what governs tooth segmentation on panoramic radiographs

The study evaluates automatic tooth segmentation on panoramic radiographs using a large annotated corpus of 1,422 images and 42,142 tooth polygons. It finds that increasing input resolution improves boundary precision (mask mAP50‑95 rises from 0.656 to 0.717) while detection performance remains unchanged, and that architectural changes have minimal impact on in‑domain accuracy. Targeted interventions such as LoRA adaptation, promptable foundation models, and anatomical label assignment provide negligible gains, indicating that resolution and acquisition diversity should be prioritized over model novelty.

By Muhammad Rehan, Moaz Amjad, Syed Danial Ahmed, Mariam Adnan, Haider Ali