KneePreM: Towards 3D Knee MRI Foundation Models via Large-Scale Unlabeled Pretraining and Label-Efficient Fine-Tuning
Read the original on arXiv Computer Vision →The Flow has not summarised this story yet — read it at arXiv Computer Vision.
The Flow has not summarised this story yet — read it at arXiv Computer Vision.
arXiv:2607. 20028v1 Announce Type: cross Abstract: Robust out-of-the-box performance is essential for the clinical deployment of deep learning models in medical imaging.
arXiv:2604. 23435v2 Announce Type: replace-cross Abstract: Grading knee osteoarthritis (KOA) on plain radiographs is poorly reproducible across readers.
The study investigates how refined annotations versus model training changes affect pulmonary embolism segmentation performance. By re‑annotating 149 CT pulmonary angiography cases and evaluating two pretrained nnU-Net models, the authors find that improving annotation quality increases the Dice similarity coefficient (DSC) by 0.143–0.188, far exceeding the 0.028 DSC change from altering training datasets. A new human‑referenced benchmark model (nnPE) was trained and publicly released, though it performed below all annotators in paired comparisons.
The study investigates how few expert-annotated cases are needed to fine‑tune MedSAM3 for abdominal organ segmentation using Low‑Rank Adaptation (LoRA). With only 10 annotated CT or MRI cases, the LoRA‑adapted models achieve performance comparable to specialist systems that require orders of magnitude more data, including reliable gallbladder segmentation and near‑state‑of‑the‑art results for liver, kidneys, and spleen. The approach also generalizes to cardiac segmentation on the Whole Heart dataset, and training takes only 3–5 hours per organ on a single GPU, roughly twice as fast as nnU-Net.
Med-AR introduces two autoregressive vision‑language models, Med‑AR‑8B and Med‑AR‑2B, pretrained on structured radiology reports, abnormality‑focused text, and region annotations to address long‑tailed chest X‑ray classification. The models outperform existing contrastive, self‑supervised, and supervised encoders—including Med‑CLIP, CheXFound, EVA‑Base, ARK, and BioViL‑T—across PadChest, MIMIC‑CXR, and CheXpert, achieving higher mean AUROC and AUPRC for head, medium, and tail findings and lower excess area under the risk‑coverage curve. Med‑AR also demonstrates improved selective‑prediction performance, with Med‑AR‑8B raising tail‑label mean AUPRC on MIMIC‑CXR from 0.1033 to 0.1441 and Med‑AR‑2B delivering the strongest discrimination on PadChest.
arXiv:2609.10125v1 Announce Type: new Abstract: Trochlear dysplasia (TD) is an abnormality of the femoral trochlea associated with anterior knee pain and patellar instability. The sulcus angle (SA) i...