The study compares five deep‑learning models—Nested U‑Net, ResU‑Net, nnUnet, Swin‑Unet, and MedSegDiff—plus a classical thresholding baseline for segmenting geographic atrophy (GA) in en‑face OCT images. Using a dataset of 269 OCT volumes from two devices (Cirrus and Spectralis) and a three‑step preprocessing pipeline, nnUnet achieved the highest Dice similarity coefficient (0.8882 ± 0.0033) on a held‑out validation set. The other models scored lower, with Dice values ranging from 0.6886 to 0.8453.
Why it matters: The results show that nnUnet offers the most reliable performance for GA segmentation in en‑face OCT, providing a better balance of accuracy, stability, and efficiency under limited data conditions.
By Utkarsh Doshi, Adarsh Gadari, Sharat Chandra Vupparaboina, Joseph DeCicco, Giulia Gregori, Nicola Valsecchi, Nasiq Hasan, Elham Sadeghi, Jos\`e-Alain Sahel, Jay Chhablani, Kiran Kumar Vupparaboina, Sandeep Chandra Bollepalli
arXiv:2509.25549v3 Announce Type: replace-cross
Abstract: Choroidal nevi are common benign pigmented lesions in the eye, with a small risk of transforming into melanoma. Early detection is critical t...
By Mohammadmahdi Eshragh, Emad A. Mohammed, Behrouz Far, Ezekiel Weis, Carol L Shields, Sandor R Ferenczy, Trafford Crump
The paper presents a two‑pipeline framework for retinal fundus analysis that combines four‑class disease classification with vessel segmentation. It fine‑tunes eight ImageNet‑pretrained CNNs on the FIVES dataset, applies five gradient‑based explanation methods to assess model interpretability, and benchmarks ten U‑Net variants—including transformer‑based and attention‑enhanced architectures—on the FIVES and DRIVE datasets. The best classification results come from ResNet101 (94.17% accuracy), while the strongest segmentation performance is achieved by Attention U‑Net with a ResNet101V2 backbone, improving DRIVE IoU from 60.80% to 64.83%.
By Fatema Tuj Johora Faria, Mukaffi Bin Moin, Pronay Debnath, Asif Iftekher Fahim, Faisal Muhammad Shah
arXiv:2607. 16065v1 Announce Type: cross Abstract: Retinal layer segmentation in Optical Coherence Tomography (OCT) is a fundamental step for extracting quantitative biomarkers of retinal structure.
By Iker Moran-Cavero, Monica Hernandez, Elvira Mayordomo, Naiara Artiaga, Beatriz Pardi\~nas, Beatriz Cordon, Elena Garcia-Martin
arXiv:1812.00877v2 Announce Type: replace-cross
Abstract: Segmentation of skin lesion boundaries in dermoscopic imaging is an important prerequisite step for computer-aided diagnosis of malignant mel...
By Glib Kechyn
OptiModNet is a lightweight UNet‑Transformer hybrid designed for optic disc and cup segmentation. It incorporates grouped‑query and channel attention across multiple stages, along with an Aggregated Pyramid Loss to improve gradient flow and structural consistency. Evaluated on the REFUGE2 dataset, it surpasses existing methods by over 2.5 % while using only 3.73 GFLOPs and 1.93 M parameters.
By Soumili Ghosh, Debapriya Roy, Aryan Das, Bikash Santra
The study evaluates four deep‑learning segmentation architectures—Unet, PSPNet, Linknet, and FPN—paired with six pre‑trained encoders to predict COVID‑19 lesions in CT images. Experiments on three COVID‑19 CT datasets show high accuracy, achieving a maximum binary F1‑score of 98% and multi‑class F1‑scores of 75% and 77%. The work aims to provide a standardized performance benchmark for medical image segmentation and a reference for other imaging scenarios.
By Sarmad Khan, Basim Azam, Arslan Shaukat
This study presents four deep‑learning pipelines—two‑dimensional and three‑dimensional—for segmenting age‑related macular degeneration (AMD) and diabetic macular edema (DME) lesions in optical coherence tomography (OCT) images. The models achieve Dice scores between 0.76 and 0.82 and demonstrate strong volumetric and surface calibration (r_vol, r_surf ≥ 0.97) on an in‑domain validation set. Generalization was assessed on the OLIVES clinical cohort using proxy metrics such as biomarker AUROC, central subfield thickness correlation, and longitudinal concordance, showing that the predictions still track clinical biomarkers outside the training distribution, albeit with reduced strength.
By Lucia Sundberg, Zhihao Zhao, M. Ali Nasseri
The study evaluated a pragmatic deep‑learning approach for segmenting acute ischemic stroke lesions on diffusion‑weighted MRI. Using a self‑configured nnU‑Net trained on 1,744 cases and tested on 436, the baseline model achieved a median Dice similarity coefficient of 0.84, outperforming the DeepISLES ensemble, especially for smaller infarcts. The approach required minimal preprocessing and fast inference, suggesting it could streamline clinical stroke imaging workflows.
By Atle Bj{\o}rnerud, Till Schellhorn, Thor H. Skatt{\o}r, Terje Nome, Jon Andr\'e Ottesen, Anne Hege Aamodt, Bradley J MacIntosh
arXiv:2608. 15915v1 Announce Type: cross Abstract: Lung cancer remains the leading cause of cancer-related mortality worldwide, while histopathological diagnosis is often affected by inter-observer variability and the substantial workload associated with manual slide examination.
By Hadi Hasan, Safaa Salman, Lama Sleem, Ralph Mouawad, Ali Chehab
arXiv:2606. 03069v1 Announce Type: cross Abstract: Generalized segmentation of medical images prevents performance degradation when different imaging devices and clinical protocols are used across multiple domains.
By Aqsa Naseer, Maryam Bibi, Syeda Samiya Urooj, Muhammad Khurram Shahzad
The study evaluates EfficientNet variants B0–B7 for classifying retinal diseases from spectral-domain optical coherence tomography (SD‑OCT) images at a fixed 224×224 resolution. Eight ImageNet‑pretrained models were tested on the Kermany dataset, with training involving a frozen‑backbone head followed by partial fine‑tuning. Results show non‑monotonic accuracy, with B1 achieving the highest overall accuracy (96.95%) and best Drusen F1, while B7 offered a secondary accuracy gain at the cost of larger model size and CPU latency.
By Shkelqim Sherifi