arXiv:2609.16551v1 Announce Type: new
Abstract: Self-supervised learning (SSL) can reduce the need for labelled medical images, but the choice of pretext objective remains unclear for lung ultrasound...
By Moein Heidari, Junbo Rao, Jai Choraria, Wenjin Chen, David J. Foran, Ilker Hacihaliloglu
arXiv:2610.03290v1 Announce Type: cross
Abstract: Lung ultrasound (LUS) is attractive for tuberculosis (TB) screening at primary-care level, but labelled cohorts are small. Echocardiography carries n...
By Christiaan M. Geldenhuys, Joshua M. Jansen van V\"uren, V\'eronique Suttels, Trevor Brokowski, Ablo P. Wachinou, Mary-Anne Hartley, Rensu P. Theart, Grant Theron, Thomas R. Niesler
arXiv:2608.30467v1 Announce Type: new
Abstract: Deep-learning models can achieve strong chest X-ray (CXR) classification performance without establishing whether their predictions predominantly rely...
By Abdullah Al Mamun, Md. Nasif Osman Khansur, Md Ashraful Hossen Akash, Md. Kishor Morol, Tze Hui Liew
arXiv:2610.17573v1 Announce Type: cross
Abstract: Self-supervised pretraining has expanded the pool of 3D medical foundation models, but published evaluations use different datasets, endpoints and fi...
By Jiaqi Tang, Yu Wang, Yang Liu, Jing Tao, Fandong Zhang, Zhou Zhen, Xiahai Zhuang, Qingchao Chen, Yining Yang, Yizhou Yu
Med-AR introduces two autoregressive vision‑language models, Med‑AR‑8B and Med‑AR‑2B, pretrained on structured radiology reports, abnormality‑focused text, and region annotations to address long‑tailed chest X‑ray classification. The models outperform existing contrastive, self‑supervised, and supervised encoders—including Med‑CLIP, CheXFound, EVA‑Base, ARK, and BioViL‑T—across PadChest, MIMIC‑CXR, and CheXpert, achieving higher mean AUROC and AUPRC for head, medium, and tail findings and lower excess area under the risk‑coverage curve. Med‑AR also demonstrates improved selective‑prediction performance, with Med‑AR‑8B raising tail‑label mean AUPRC on MIMIC‑CXR from 0.1033 to 0.1441 and Med‑AR‑2B delivering the strongest discrimination on PadChest.
By Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli, Preetham Putha
arXiv:2607. 20274v1 Announce Type: cross Abstract: Medical image encoders from different groups are increasingly treated as interchangeable, on the assumption that scale and clinical supervision concentrate their representations onto a shared structure.
By Soroosh Tayebi Arasteh, Sebastian Ziegelmayer, Mahshad Lotfinia, Lisa Adams, Sven Nebelung, Jakob Nikolas Kather, Daniel Truhn
OmniMed‑FL is a multimodal federated learning framework that fuses chest radiographs and synthetic patient notes to classify five clinical conditions. The study benchmarks eight fusion strategies, three initializations, and four missing‑text imputation rules across 3–20 hospital clients under non‑IID Dirichlet partitioning, showing that federated approaches (FedAvg, FedProx, SCAFFOLD‑AdamW) outperform local‑only training. Multimodal fusion consistently improves performance, achieving macro‑F1 scores up to 0.956 on the synthetic corpus and 0.906 on the radiograph corpus.
By Ayush Debnath, Ruelia Saha, Sudip Misra
Deep-learning models can achieve strong chest X-ray (CXR) classification performance without establishing whether their predictions predominantly rely on pulmonary image content. This study evaluates...
arXiv:2607. 22351v1 Announce Type: new Abstract: The speed of sound in tissue is a prerequisite for well-focused imaging and has diagnostic value, but recovering it from raw pulse-echo channel data is fundamentally a nonlinear inverse problem.
By Masashi Sode, Gianmarco Pinton
DALE-CT introduces depth‑aware 2D slice encoders that learn an anatomical world model of chest CT scans without 3D or positional supervision. By sampling self‑supervised views across a physical $z$‑axis slab, the encoder captures how anatomy changes between neighboring slices, enabling it to recover slice ordering and distinguish slices by anatomy alone. The model, trained on a large 287k‑scan corpus, achieves state‑of‑the‑art performance on CT‑RATE and is released with full code and evaluation tools.
By Evan W. Damron, Mahmut S. Gokmen, Mitchell A. Klusty, Caroline N. Leach, Emily B. Collier, V. K. Cody Bumgardner
Lumen is a pathology vision‑language model that aligns frozen unimodal foundation models (Virchow2 and BioMedBERT) using rank‑4 adapters and projection heads, training only 0.40% of the total parameters on the QUILT‑1M corpus. It achieves the highest mean chance‑corrected balanced accuracy (0.546) across nine zero‑shot patch benchmarks and demonstrates strong performance on lymph‑node metastasis detection, with AUROC scores of 0.964 internally and 0.955 externally. While it ranks third in cross‑modal retrieval, Lumen’s low‑parameter training yields competitive results at both patch and slide levels.
By Kiarash Tajbakhsh, Abdelrahman Faqieh, Michael Jopiti, Javier Garcia-Baroja, Philipp Zens, Branislav Zagrapan, Yuri Tolkach, Martin D. Berger, Aurel Perren, Bastian Dislich, Inti Zlobec, Amjad Khan
The paper investigates why CLIP-style contrastive image‑text pretraining fails in radiology, noting that zero‑shot performance peaks then degrades and large batches cause training collapse. By creating a synthetic CLEVR‑Radiology testbed that isolates overlapping clinical facts, the authors show that the paired‑identity target is structurally biased. They propose CorLIP, a minimal compatibility‑based correction that treats a report as positive when its clinical assertions agree with the image, which removes post‑peak degradation, enables stable large‑batch training, and improves performance across modalities.
By Yunhe Gao, Ashwin Kumar, Jiaming Liu, Chong Wang, Maya Varma, Fuying Wang, Stefania L. Moroianu, Louisa Fay, Sergios Gatidis, Akshay S. Chaudhari, Curtis Langlotz