arXiv Machine Learning

Rethinking Contrastive Targets in Radiology Language-Image Pretraining

The paper investigates why CLIP-style contrastive image‑text pretraining fails in radiology, noting that zero‑shot performance peaks then degrades and large batches cause training collapse. By creating a synthetic CLEVR‑Radiology testbed that isolates overlapping clinical facts, the authors show that the paired‑identity target is structurally biased. They propose CorLIP, a minimal compatibility‑based correction that treats a report as positive when its clinical assertions agree with the image, which removes post‑peak degradation, enables stable large‑batch training, and improves performance across modalities.

arXiv AI
Oct 27

Meta-CLIP: Metadata-Conditioned Contrastive Learning for Zero-Shot Disease Inference

Meta-CLIP is a metadata‑conditioned contrastive learning framework that incorporates DICOM acquisition information to reweight cross‑modal negatives during medical vision‑language pretraining. By defining a bounded pairwise margin over numerical and categorical DICOM fields, the method emphasizes distinctions among studies with similar imaging conditions while keeping the kernel fixed during optimization. Evaluations on chest radiography and volumetric CT show that Meta‑CLIP improves zero‑shot classification performance, achieving higher macro‑AUROC scores than baseline CLIP models on multiple benchmarks.

By Haozhe Luo, Nirosh Sivanesan, Shelley Zixin Shu, Francesco Nitti, Mauricio Reyes
arXiv Computer Vision
Oct 16

SCCL-DT: Semantic-Conflict-Aware Contrastive Learning with Dual-Rule Teacher Distillation for Zero-Shot Chest X-Ray Diagnosis

The paper introduces SCCL-DT, a method that improves zero‑shot chest X‑ray diagnosis by addressing semantic conflicts in contrastive vision‑language pre‑training. It uses adaptive thresholds derived from exponential‑moving‑average statistics to hard‑mask conflicting pairs, and combines two teachers—an inclusive and a consensus rule—through distillation into a single student model. On five public chest X‑ray benchmarks, SCCL‑DT achieves a mean zero‑shot AUC of 0.850, outperforming the best baseline at 0.837.

By Ting Liu, Haoran Lai, HaobinChen, Ming Liu, S Kevin Zhou
arXiv Computer Vision
5d ago

ProtoBridge-CLIP: Observation-Masked Finding Prototypes for Medical Image--Report Representation Learning

ProtoBridge-CLIP introduces a new framework that blends symmetric global image–report alignment with observation‑masked finding supervision and a soft relation objective over affirmed report concepts. The method aligns text‑derived finding prototypes with local visual tokens while excluding uncertain and unmentioned concepts from direct labels. Evaluations on multiple CT and chest‑radiograph benchmarks show consistent performance gains, achieving macro‑AUROC scores up to 91.4% on CheXpert and demonstrating robustness across retrieval, localization, and calibration tasks.

By Jinrui Wu, Yun Peng
Hugging Face Trending Papers
Jun 29

SHOVIR: A Benchmark for Evaluating Vision Shortcut Learning in Radiology Report Generation

Current evaluation protocols for Vision-Language Models (VLMs) in Radiology Report Generation (RRG) rely on report-level metrics that measure lexical overlap or aggregate clinical correctness. However, such metrics do not test whether individual diagnostic statements stem from the actual pathological evidence visible in the image.

arXiv Computer Vision
Aug 27

What Do Medical Vision-Language Models Learn in Radiology? Transfer, Alignment, and Source-Proxy Leakage Under Distribution Shift

The paper investigates how medical vision‑language models (VLMs) behave when faced with distribution shifts such as changes in acquisition domain, supervision, or evaluation protocol. Using datasets like NIH ChestXray14, CheXpert, PadChest, and OpenI, the authors isolate cross‑dataset visual transfer, evaluate multimodal alignment, and quantify source‑proxy leakage in frozen embeddings. They find that self‑supervised visual initialization improves transfer, adversarial adaptation is only marginally helpful, and that multimodal retrieval performance drops under external stress tests while source‑proxy information remains recoverable, highlighting hidden failure modes in medical VLMs.

By Ayoub Louaye Bouaziz, Lokmane Chebouba, Yassine Himeur
arXiv Computer Vision
Sep 4

Solving the Needle-in-a-Haystack Problem in Mammography Vision-Language Model with Differentiable Subset Sampling

The paper introduces TopKSigLIP, a vision‑language model tailored for mammography that tackles two key challenges: high‑resolution imaging and homogeneous radiology reports. It replaces standard CLIP training with a TopK‑Patch module that selects sparse high‑resolution patches likely to contain lesions, and a Sup‑sigmoid loss that uses soft labels from structured data instead of contrastive loss. TopKSigLIP outperforms existing open‑source mammography and general medical VLMs on zero‑shot tasks such as density assessment, BI‑RADS classification, finding subtyping, and cancer prediction, while also providing better lesion localization than Grad‑CAM.

By Young Seok Jeon, Beatrice Brown-Mulry, Rohan Satya Isaac, Anjana Dissanayaka, Theo Dapamede, Mohammadreza Chavoshi, Judy Gichoya, Hari Trivedi
arXiv AI
Sep 25

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

Med-AR introduces two autoregressive vision‑language models, Med‑AR‑8B and Med‑AR‑2B, pretrained on structured radiology reports, abnormality‑focused text, and region annotations to address long‑tailed chest X‑ray classification. The models outperform existing contrastive, self‑supervised, and supervised encoders—including Med‑CLIP, CheXFound, EVA‑Base, ARK, and BioViL‑T—across PadChest, MIMIC‑CXR, and CheXpert, achieving higher mean AUROC and AUPRC for head, medium, and tail findings and lower excess area under the risk‑coverage curve. Med‑AR also demonstrates improved selective‑prediction performance, with Med‑AR‑8B raising tail‑label mean AUPRC on MIMIC‑CXR from 0.1033 to 0.1441 and Med‑AR‑2B delivering the strongest discrimination on PadChest.

By Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli, Preetham Putha