arXiv:2609.14313v1 Announce Type: cross
Abstract: Robust point tracking in endoscopic videos is essential for computer-assisted intervention and autonomous robotic surgery, enabling continuous regist...
By Jiaming Zhang, Zijian Wu, Mehran Armand, Septimiu Salcudean
arXiv:2610.31951v1 Announce Type: new
Abstract: Surgical point tracking requires persistent correspondence through tissue deformation and occlusion, yet dense trajectory annotations are costly to obt...
By Bing Fan, Anwesa Choudhuri, Zhongpai Gao, Meng Zheng, Benjamin Planche, Terrence Chen, Heng Fan, Ziyan Wu
arXiv:2607.26395v2 Announce Type: replace
Abstract: White-light imaging (WLI) and narrow-band imaging (NBI) provide complementary cues for endoscopic lesion segmentation, yet their sequential acquisi...
By Pengyu Jie, Wanquan Liu, Rui He, Pengcheng Li, Weiping Wen, Deyu Meng, Junwei Han, Chenqiang Gao
PADSNet is a Physics-Aware Dual-Stream Network that classifies laryngeal lesions by combining visual features with biomechanical reasoning. It uses a Wavelet-Attention Enhancement Module to merge spatial texture and dynamic frequency representations, and a Knowledge Computing Module to extract interpretable biomechanical indices from glottal distance waveforms. These indices are fed into a Physics-Aware Gating Module to recalibrate visual features, achieving an accuracy of 0.8452, F1-score of 0.8090, sensitivity of 0.7953, and specificity of 0.8866 on a clinical dataset.
By Zhenzhen You, Weifeng Yu, Zhenghao Shi, Shuangli Du, Minghua Zhao, Yingcheng Zhao, Xinhong Hei, Demin Kong, Xiaoyong Ren, Jin Hou
SCOPE-4D is an endoscopic 4D geometry foundation model that predicts camera parameters, dense geometry, and 3D tissue trajectories from monocular RGB video in a single forward pass. The authors introduce SCOPE-5K, a curated dataset of about 5,000 real and synthetic gastrointestinal endoscopy and laparoscopy clips, and use it for geometric supervised fine‑tuning. Adding Common–Residual Motion (CRM) constraints and trajectory supervision further improves camera and depth estimation and enables dense 3D tissue tracking, as shown by evaluations on public and new benchmarks and a blinded user study.
By Chaoyi Zhou, Zhongpai Gao, Anwesa Choudhuri, Meng Zheng, Benjamin Planche, Run Wang, Terrence Chen, Siyu Huang, Ziyan Wu
RAUL is a reference‑assisted reconstruction framework that recovers ureteroscope trajectories from endoscopic video alone, using a high‑quality reference exploration video for each phantom. It achieves a mean translation error of 0.5 mm and increases frame‑wise localization coverage from 50.5 % to 86.1 % compared to standard Structure‑from‑Motion. The reconstructed trajectories reveal significant differences in navigation metrics between high‑ and low‑experience trainees, enabling objective skill assessment without external tracking equipment.
By Fangjie Li, Mai Bui, Charan Mohan, Michael Miga, Matthieu Chabanas, Nicholas Kavoussi, Jie Ying Wu
White-light imaging (WLI) and narrow-band imaging (NBI) provide complementary views of endoscopic lesions, but their paired observations are often spatially misaligned due to viewpoint changes, tissue deformation, and sequential handheld acquisition. This makes direct WLI/NBI fusion prone to mixing non-corresponding regions and may even degrade segmentation around lesion boundaries.
LapaTrack-3D is a real‑time 6 DoF tracking algorithm designed for monocular laparoscopic surgery, aligning intra‑operative video with pre‑operative CT data. It modifies the ORB‑SLAM2 framework with four key changes: fast initialization using a primitive 3D shape, a pseudo‑segmentation strategy to isolate the target organ, incorporation of the 3D shape as a geometric prior in pose graph optimization, and enhanced imaging via a modified Multi‑Scale Retinex with Chromaticity Preservation algorithm. Experiments on in‑vivo and ex‑vivo data show robust tracking under challenging conditions such as poor illumination, fast motion, and partial visibility, achieving 13 Hz on 1280×720 video.
By Jingwei Song, Javid Hussain Jakir, Ray Zhang, Wenwei Zhang, Hao Zhou, Xiaomeng Xian, Maani Ghaffari
arXiv:2608. 07116v1 Announce Type: cross Abstract: Camera localization in bronchoscopy remains a challenging problem due to stringent accuracy requirements, real-time constraints, and limited training data.
By Lumin Chen, Qingyao Tian, Jinpeng Li, Haoyu Jiang, Huai Liao, Xinyan Huang, Hongbin Liu, Dong Yi
arXiv:2608. 07176v1 Announce Type: cross Abstract: Developing foundation generative models for endoscopy is limited by the gap between natural and clinical images and the computational cost of training large Diffusion Transformers.
By Francisco Caetano, Tim J. M. Jaspers, Haiko Middeljans, Martijn R. Jong, Rixta A. H. van Eijck van Heslinga, Floor Slooter, Albert J. de Groof, Jacques J. Bergman, Peter H. N. De With, Fons van der Sommen
arXiv:2606. 17340v1 Announce Type: cross Abstract: Accurate vision-based navigation in monocular endoscopy is difficult due to limited depth cues, weak tissue texture, non-rigid deformation, and substantial appearance variation across domains, all of which complicate pose estimation, depth prediction, and image-to-anatomy alignment.
By Hongchao Shu, Roger D. Soberanis-Mukul, Hao Ding, Morgan Ringel, Mali Shen, Saif Iftekar Sayed, Hedyeh Rafii-Tari, Mathias Unberath
arXiv:2606. 18723v1 Announce Type: cross Abstract: Intravascular ultrasound (IVUS) lumen and external elastic membrane (EEM) segmentation is important for quantitative coronary plaque burden assessment.
By Yunshu Chen, Litao Yang, Giuseppe Di Giovanni, Jordan Tan, Deval Mehta, Andrew Lin, Derek Chew, Masasi Fujino, Julie Butters, Stephen Nicholls, Zongyuan Ge, Kyung Hoon Cho