White-light imaging (WLI) and narrow-band imaging (NBI) provide complementary views of endoscopic lesions, but their paired observations are often spatially misaligned due to viewpoint changes, tissue deformation, and sequential handheld acquisition. This makes direct WLI/NBI fusion prone to mixing non-corresponding regions and may even degrade segmentation around lesion boundaries.
The paper introduces MICRO, a large-scale multimodal retinal image rigid registration benchmark containing 1,365 cross‑modal image pairs annotated across preoperative, intraoperative, and postoperative surgery phases. It also proposes OFS2Reg, a one‑step registration framework that uses frequency‑guided structure preservation descriptors and cross‑modal vessel similarity learning to impose keypoint topology constraints, aiming to improve registration accuracy without relying on segmentation. The benchmark and method together address the lack of public datasets and the limitations of current two‑step segmentation‑then‑detection approaches.
By Mingdao Gong, Yan Hu, Mingzhen Yuan, Jialu Zhang, Junming Feng, Yiming Jiang, Jing Ma, Jinghua Liu, Huazhu Fu, Hai Lu, Xiaoqing Zhang, Jiang Liu
arXiv:2609.24560v1 Announce Type: new
Abstract: Confocal Laser Endomicroscopy (CLE) provides real-time, cellular-resolution optical biopsy but has a narrow field of view, which image mosaicing can ex...
By Ahmed Aboelela, Johannes Barcsay, Jana Friedhof, Miguel Gon\c{c}alves, Alexander Hann, Katharina Breininger
arXiv:2609.15669v1 Announce Type: cross
Abstract: Multimodal image registration is a key component of many clinical workflows, yet it remains challenging because corresponding anatomical structures o...
By Matteo Barbieri, Giammarco La Barbera, Juan Pablo De La Plata, Sabine Sarnacki, Isabelle Bloch, Pietro Gori
Multimodal image registration is a key component of many clinical workflows, yet it remains challenging because corresponding anatomical structures often exhibit substantially different image intensit...
ReliMorph is a novel 3D deformable registration framework that integrates correspondence reliability with spatial expert routing and residual velocity gating. By using local correlation distributions to assess match ambiguity, the method guides expert fusion and velocity updates during coarse‑to‑fine refinement, with inverse‑inconsistency feedback refining decisions at finer levels. Experiments show that ReliMorph consistently improves anatomical overlap over competing methods in both unimodal and multimodal registration tasks.
By Chenyu Guo, Wenjie Dai, Yiqian Chang, Zhiyuan Zhang, Yunfan Wei, Shuhan Qi
Diff‑RF is a diffusion‑based framework that jointly performs image registration and fusion while accounting for degradation in multi‑modal images. It first restores modality‑specific degradations within each image, then uses a cross‑modal diffusion module that couples registration and fusion, refining alignment and enhancing complementary information. Experiments on extended datasets show that this coupled approach yields higher registration accuracy and fusion quality under diverse degraded conditions.
By Xunpeng Yi, Zaixi Du, Qinglong Yan, Yibing Zhang, Han Xu, Jiayi Ma
arXiv:2608.28341v1 Announce Type: new
Abstract: Precise dense correspondence is a fundamental prerequisite for multimodal spectral imaging systems that fuse disparate wavelength ranges for subsequent...
By Eric L. Wisotzky, Jost Triller, Simon W. H\"artl, Oliver T. Bruns, Peter Eisert, Anna Hilsmann
arXiv:2610.33125v1 Announce Type: cross
Abstract: Reliable visual tracking of anatomical landmarks in endoscopic video is a key prerequisite for computer-assisted interventions in laryngeal surgery....
By Jonas Below, Piermarco Gerli, Anna J\"otten, Dennis Eggert, Axelle Felicio-Briegel, Veronika Volgger, Christian Betz, Alexander Schlaefer
CEM‑TUDASR is a lightweight, unsupervised Transformer-based super‑resolution framework designed to enhance low‑resolution images from Wireless Capsule Endoscopy (WCE). It uses a domain‑adaptive degradation network to generate realistic WCE‑like low‑resolution images from high‑resolution conventional endoscopy data, enabling effective unpaired learning. The model incorporates Deep Attention Blocks and a Fusion Attention Block to capture both global context and fine local details, achieving superior performance on WCE datasets and demonstrating cross‑domain adaptability to retinal images, all while keeping the parameter count and computational load low.
CEM‑TUDASR is a lightweight, unsupervised Transformer‑based super‑resolution framework designed for Wireless Capsule Endoscopy (WCE) images. It uses a domain‑adaptive degradation network to synthesize realistic low‑resolution WCE images from high‑resolution conventional endoscopy data, enabling unpaired training. The SR generator incorporates Deep Attention Blocks and a Fusion Attention Block to preserve both global context and fine local structures, achieving superior no‑reference quality metrics and improved restoration of mucosal textures, vascular patterns, and anatomical details while remaining computationally efficient.
By Anjali Sarvaiya, Jay Kadel, Kishor Upla, Kiran Raja
Objective. Deformable image registration remains challenging because corresponding anatomy may exhibit different intensity relationships. Hand-crafted modality-robust descriptors such as Modality-Inde...