arXiv:2608. 08173v1 Announce Type: cross Abstract: Longitudinal MRI enables sensitive measurement of structural brain change for studying aging and neurodegenerative disease.
By Jingru Fu, Kathleen E. Larson, Douglas N. Greve, Bruce Fischl, Malte Hoffmann
The paper presents a diffeomorphic coarse‑to‑fine LapIRN architecture adapted for longitudinal whole‑body PSMA PET/CT registration in the Learn2Reg 2026 PSMAReg challenge. The method integrates affine pre‑registration, multi‑modal deformable registration, and test‑time instance optimization, and introduces PET biomarker preservation losses for metabolic tumor volume (MTV) and total lesion glycolysis (TLG) with Jacobian‑based constraints and per‑structure rigidity regularization for skeletal structures. The submitted configuration achieved 81.0 % Dice similarity coefficient, 6.17 mm HD95, and 3.3 % errors in MTV and TLG on the evaluation protocol.
By Fryderyk K\"ogl, Anna Reithmeir, Daniel M. Lang, Emily Chan, Rickmer Braren, Julia A. Schnabel
The paper introduces DB‑SUiT, a surface‑based diffusion bridge that translates cortical MRI to PET images directly on the cortical manifold. It employs a conditional spherical U‑shaped vision Transformer to capture multi‑scale surface features and long‑range dependencies while incorporating demographic and subcortical information. Evaluations on two dementia datasets show that the synthesized PET surfaces outperform MRI and PET volumes in automated classification and achieve high diagnostic accuracy in a blinded reader study.
By Yitong Li, Alexandra Samoylova, Fabian Bongratz, Timo Grimmer, Dennis M. Hedderich, Igor Yakushev, Christian Wachinger
arXiv:2608. 19769v1 Announce Type: cross Abstract: Fast and accurate segmentation of Acute Ischemic Stroke (AIS) lesions is essential for stroke prognosis and treatment planning.
By Maunil Shah, Vaanathi Sundaresan
arXiv:2508.17171v3 Announce Type: replace
Abstract: Imaging biomarkers in magnetic resonance imaging (MRI) are important tools for diagnosing, tracking and treating Alzheimer's disease (AD). Neurofib...
By Yue Li, Pulkit Khandelwal, Rohit Jena, Long Xie, Michael Duong, Amanda E. Denning, Christopher A. Brown, Laura E. M. Wisse, Sandhitsu R. Das, David A. Wolk, Paul A. Yushkevich
The paper presents a method for the BIC-MAC challenge, aiming to generate pseudo‑CT images from NAC‑PET, DIXON MRI, and a topogram, and to evaluate both the pseudo‑CT and the resulting attenuation‑corrected PET. The authors improve upon a 3D U‑Net baseline by focusing on loss design: they compute an L1 error in the Carney attenuation‑coefficient space, weighted by anatomical region, and incorporate DIXON MRI as additional input only after this loss was applied. Finally, they fuse two independently trained models via a fixed convex combination, achieving better performance than either model alone and topping the public validation leaderboard.
By Khoa Tuan Nguyen, Joris Vankerschaver, Wesley De Neve
arXiv:2602. 22545v3 Announce Type: replace-cross Abstract: Tau positron emission tomography supports Alzheimer's disease staging but is difficult to scale because of tracer, scanner, and radiation constraints.
By Agamdeep S. Chopra, Caitlin Neher, Tianyi Ren, Juampablo E. Heras Rivera, Hesamoddin Jahanian, Mehmet Kurt
The study introduces a physics‑guided, self‑supervised deep learning framework that estimates macromolecular pool fraction (MPF) maps directly from conventional clinical brain MRI sequences (T1‑, T2‑, and FLAIR) without requiring specialized quantitative magnetization transfer scans. By embedding an analytical two‑pool magnetization transfer model and conditioning on acquisition parameters, the method was trained on 7,705 multisite, multivendor MRI sessions and achieved consistent MPF values across vendors and protocols, with a 35.6% reduction in lesions of demyelinating disease compared to normal‑appearing white matter. Cross‑protocol validation in a healthy volunteer showed a mean voxel‑wise absolute difference of 7.7% and a concordance correlation coefficient of 0.888, demonstrating robust cross‑protocol performance.
By Jelmer van Lune, Miha Fuderer, Oscar van der Heide, Matteo Maspero, Martin B. Schilder, Jan Willem Dankbaar, Stefano Mandija, Alessandro Sbrizzi
Domain Elastic Transform (DET) is a grid‑free, probabilistic framework that jointly aligns geometry and high‑dimensional vector‑valued functions on irregular sparse manifolds, such as those found in spatial transcriptomics. By treating data as functions rather than voxelized images, DET performs unsupervised, scalable registration through sampled point alignment and displacement interpolation, guided by a joint spatial‑functional Bayesian likelihood. Evaluations on MERFISH mouse‑brain slices and Stereo‑seq mouse‑embryo atlases show DET achieving superior spatial overlap and topology compared to existing pipelines, with an accelerated variant delivering high label‑transfer accuracy.
By Osamu Hirose, Emanuele Rodola
arXiv:2609.05484v1 Announce Type: cross
Abstract: Deep learning registration methods routinely stack two kinds of enhancement on a base network: architectural additions such as affine pre-alignment s...
By Nabira Rashid
arXiv:2606. 29577v1 Announce Type: cross Abstract: Positron Emission Tomography (PET) reveals brain metabolism and is clinically central to neurodegenerative disease assessment, yet existing 3D brain foundation models treat PET as generic volumetric data, missing the structured regional metabolic information that distinguishes it from structural neuroimaging.
By Dasen Dai, Yanteng Zhang, Shuoqi Li, Yuxiang Wei, Hongjie Yu, Qingxin Zhang, Qizhen Lan, Jagath C. Rajapakse, Vince D. Calhoun
The paper introduces UMD, a paired whole‑body dataset of 490 PET/CT and 464 PET/MRI exams with 13 organ annotations, designed to evaluate segmentation foundation models on both structural (CT/MRI) and functional (PET) images within the same patient. Five representative 3D foundation models were benchmarked on UMD, revealing generally poor PET segmentation performance and, in some cases, near‑zero overlap on CT or MRI. These results underscore the necessity of testing model generalization across imaging modalities and highlight opportunities for improving cross‑modality performance.
By Yichi Zhang, Le Xue, Feiyang Xiao, Wenbo Zhang, Gang Feng, Chenguang Zheng, Yuan Qi, Yuan Cheng, Zixin Hu