arXiv Computer Vision

Feasibility of a Patient-Specific Digital Twin for Ventriculoperitoneal Shunt Trajectory Planning

arXiv AI
Oct 1

An Uncertainty-Guided Digital Twin Framework for Online Adaptive Proton Therapy in Head and Neck Cancer: A Feasibility Study

arXiv:2609.39010v1 Announce Type: cross Abstract: Objective: Head and neck (HN) proton therapy spans six to seven weeks of anatomical change, while offline replanning takes about a week. We present a...

By Yizhou Wu, Ryan J. Sanford, Huiqiao Xie, Jie Ding, Shupeng Chen, Tung-Ho Wu, Ping-Hsiu Wu, Justin Roper, Jun Zhou, Minglei Kang, Bill Stokes, Sibo Tian, David S. Yu, Xiaofeng Yang, Chih-Wei Chang
arXiv Computer Vision
2d ago

When can multi-fragment 2D/3D registration be trusted? Calibrated certification and uncertainty-driven view planning for pelvic fracture fluoroscopy

The paper presents a closed‑loop system for registering segmented CT fracture fragments to fluoroscopy, providing calibrated uncertainty bounds and flagging implausible or ambiguous fragments. After each shot, the system updates all fragment registrations, stops or plans the next view based on whether new views keep fragment positions within their bounds, and uses uncertainty‑driven planning to reduce the number of shots needed. Experiments on simulated fluoroscopy of 60 held‑out pelvic fractures show that 95% of the bounds cover 83% of unflagged fragments, with 91% of those within 5 mm, and that a simple rule requiring no fragment to move beyond its bound reduces false stops from 23% to 6% at a 2 mm threshold. "whyItMatters":"The study demonstrates that calibrated uncertainty and view‑planning can make multi‑fragment 2D/3D registration reliable enough to guide pelvic fracture surgery, potentially improving surgical accuracy and efficiency."

By Bowen Xiang, Michael I. Miga
arXiv AI
Aug 11

Enhanced Real-Time 6-DOF Extended Reality Catheter Tracking for Evaluating Potential Improvement in Efficiency, Precision, and Depth Perception for Cardiac Interventions

arXiv:2608. 07606v1 Announce Type: cross Abstract: Despite advances in 3D ultrasound, most percutaneous cardiac interventions still rely on 2D visualization, limiting depth perception and spatial understanding.

By Mohsen Annabestani, Sandhya Sriram, Andrew Kuzemczak, S. Chiu Wong, Alexandros Sigaras, Bobak Mosadegh
arXiv AI
2d ago

Risk Control Certifies Rates, Not Magnitudes: An Audit of Selective Fetal Biometry

The paper audits a prenatal ultrasound biometry pipeline that predicts head circumference (HC) while certifying a maximum error rate rather than magnitude. Using two pre‑registered splits of 999 HC18 images, the authors retrain the segmenter three times per split and calibrate a contour‑completeness threshold via exact Clopper–Pearson risk control. Although the certified risk bound (α = 0.10) remains intact, the pipeline still produces a large 271.3 mm error on a single image, and tightening the admissibility region to an anatomically defined range reduces worst‑case errors to about 11 mm while only modestly affecting coverage.

By Zhengshuai Yang, Linna Jiang, Changyun Li, Guihu Zhao
arXiv Machine Learning
5d ago

Transport What Shares the Conduction Pathway: Normal-Anchored SPD Geometric Transport for Source-Free Patient Adaptation of Holter and Patch ECG

The paper introduces Normal-Anchored Geometric Transport (NAGT), a source‑free adaptation technique that uses label‑free normal beats from the first five minutes of ECG recordings to compute a symmetric positive‑definite congruence map. NAGT applies this map only to normal and supraventricular prototypes while keeping ventricular and fusion prototypes unchanged, achieving a macro‑F1 improvement from 34.5% to 48.7% on a large chest‑patch cohort. The method also reduces ventricular false alarms by 68% and maintains 98.3% of normal beats outside alarm classes, with adaptation taking only 5.8 ms per record.

By JinKook Kim
arXiv Machine Learning
Oct 5

Autonomous Robotic Navigation for Endovascular Brain-Computer Interface Access

The paper reports the first demonstration of autonomous robotic navigation for endovascular brain‑computer interface access in the cerebral venous system. Soft Actor‑Critic controllers were trained in simulation to navigate from the right internal jugular vein to the superior sagittal sinus, and were evaluated both in silico and in vitro, achieving high success rates in simulation and 70% overall in physical runs. Online failure‑prediction models were also tested, detecting most failures with low false‑alarm rates, though calibration degraded when transferring from simulation to physical experiments.

By Harry Robertshaw, Weijie Qi, Nikola Fischer, Alejandro Granados, Thomas C. Booth, Sam E. John