3D brain MRI generation has made significant advances in medical imaging, simulation, and controllable anatomical analysis. However, existing generative models typically synthesize 3D volumes monolith...
arXiv:2606. 18354v1 Announce Type: cross Abstract: Recent advances in generative machine learning models have significantly improved medical imaging, offering promising solutions for data augmentation, privacy preservation, and improved model generalization.
By Muge Zhang, Muhammad Ali Khaliq, Jamal Alsakran, Byeong Kil Lee, Jeeho Ryoo
arXiv:2603. 05693v2 Announce Type: replace-cross Abstract: Accurate longitudinal analysis of brain MRI is often hindered by evolving lesions, which bias automated neuroimaging pipelines.
By Zahra Karimaghaloo, Dumitru Fetco, Haz-Edine Assemlal, Hassan Rivaz, Douglas L. Arnold
arXiv:2606. 15457v1 Announce Type: cross Abstract: 3D FLAIR MRI is widely recommended as one of the standard MRI sequences for brain imaging in multiple sclerosis (MS), but publicly available MS datasets remain relatively small and vary across scanners, acquisition protocols, and lesion patterns.
By Weidong Zhang, Yongchan Jung, Shafayat Mowla Anik, Furen Xiao, Vasudevan Janarthanan, Enkhzaya Chuluunbaatar, Byeong Kil Lee, Jeeho Ryoo
arXiv:2606. 19651v1 Announce Type: new Abstract: Three-dimensional (3D) brain MRI is central to clinical neurology and neuro-oncology, where generative models could augment under-represented cohorts, simulate disease trajectories, and support privacy-preserving data sharing.
By Max Van Puyvelde, Ibrahim Gulluk, Wim Van Criekinge, Olivier Gevaert
arXiv:2602. 18400v3 Announce Type: replace-cross Abstract: Missing data problems, such as missing modalities in multi-modal brain MRI and missing slices in cardiac MRI, pose significant challenges in clinical practice.
By Junkai Liu, Nay Aung, Theodoros N. Arvanitis, Joao A. C. Lima, Steffen E. Petersen, Le Zhang
arXiv:2604. 22700v2 Announce Type: replace Abstract: Modeling and predicting neurodegenerative disease progression from medical images remains a major challenge in medical AI, with significant implications for early diagnosis, disease monitoring, and treatment planning.
By Nivetha Jayakumar, Swakshar Deb, Bahram Jafrasteh, Qingyu Zhao, Miaomiao Zhang
arXiv:2606. 26764v1 Announce Type: cross Abstract: Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions.
By Yiheng Cao, Gustavo Andrade-Miranda, Jiatian Zhang, Lingxiao Zhao, Xin Gao
Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions. To address this, we propose a 4D controllable generative framework for anatomically consistent data augmentation.
arXiv:2603. 04024v2 Announce Type: replace-cross Abstract: Ambiguous 3D medical image segmentation often involves boundaries where different expert delineations are non-identical yet clinically plausible.
By Chao Wu, Mahesh Bhosale, Kangxian Xie, Pouya Karimian, David Doermann, Mingchen Gao
arXiv:2607. 29337v1 Announce Type: cross Abstract: Background and Objective: Generating realistic medical images with anatomically accurate segmentation masks helps address the shortage of annotated data in medical imaging, particularly in optical coherence tomography (OCT) of mouse eyes, where manual retinal layer delineation is labour-intensive due to tiny structures and required expertise, resulting in scarce datasets.
By Fernando Garc\'ia-Torres, Roc\'io del Amor, Sandra Morales, \'Alvaro Barroso, Peter Heiduschka, Bj\"orn Kemper, Valery Naranjo
The paper introduces AGW-PBR, a brain MRI super‑resolution method that emphasizes tissue‑transition regions affected by the partial‑volume effect. It uses a low‑resolution backbone guided by Sobel edges, soft latent‑basis assignment, and grid‑anchored warping, while training‑time weights are derived from tissue‑mixture entropy computed from registered T1/T2/PD images. Experiments on IXI T2‑weighted scans at 2×, 4×, and 6× show improved full‑image reconstruction and regional fidelity, and the backbone also performs well on fastMRI data without PVE supervision.
By Xiao Tong, Wenyun Yang, Ziheng Zhang, Jingzhi Han, Zhaochu Luo, Jinbo Yang