arXiv:2606. 11125v1 Announce Type: cross Abstract: Blood pressure (BP) is a key marker for cardiovascular risk assessment and therapeutic decision-making, and Photoplethysmography (PPG) enables low-cost, wearable-friendly cuffless BP estimation.
By Yidan Shen, Neville Mathew, Maham Rahimi, Deependra Dhakal, George Zouridakis, Xin Fu, Renjie Hu
arXiv:2607. 27076v1 Announce Type: new Abstract: Continuous cuffless blood pressure (BP) monitoring remains challenging due to motion artifacts, physiological variability, and the limited robustness of conventional pulse transit time (PTT) models under dynamic conditions.
By Kindeep K. Dhatt, Tengyue Wu, Hanbang Hua, Yayun Du
arXiv:2607. 23406v1 Announce Type: cross Abstract: Continuous cuffless blood pressure (BP) monitoring is essential for connected health systems and wearable devices, enabling early detection, longitudinal tracking, and personalized management of cardiovascular disease.
By Bo Wu, Haoling Wang, Zhuodiao Kuang, Kateryna Shapovalenko
arXiv:2609.13190v1 Announce Type: new
Abstract: Continuous cuffless blood pressure (BP) monitoring using photoplethysmography (PPG) offers a promising solution for personalized healthcare. However, e...
By Myung-Kyu Yi, Jongshill Lee, Jeyeon Lee, In Young Kim
arXiv:2605.10871v3 Announce Type: replace-cross
Abstract: We present Attractor-Vascular Coupling Theory (AVCT), a theory-guided framework for deriving interpretable blood pressure (BP) predictors fro...
By Timothy Oladunni, Farouk Ganiyu Adewumi
The paper presents a hybrid Transformer framework that estimates non‑invasive continuous blood pressure from ECG/PPG‑derived feature sequences. It models 10‑step sequences of six physiological descriptors and two demographic covariates, combining Transformer, Kolmogorov‑Arnold Network, and XGBoost modules, and uses a dynamic fusion decoder to predict diastolic and systolic BP. On a large MIMIC‑III dataset, the model achieved mean errors of 0.41 mmHg (diastolic) and –1.60 mmHg (systolic) with high accuracy within 10 mmHg for most predictions.
By Yuexin Ma, Jingqi Hou, Yuxuan Kang, Zhaoying Liu
PPG-Bench is an open‑source benchmark that evaluates five publicly available photoplethysmography (PPG) foundation models across nine datasets and 26 tasks, covering cardiovascular state estimation, activity, sleep, screening, and identification. The benchmark tests models under four downstream regimes—linear probing, random forests, frozen MLP probes, and end‑to‑end finetuning—while also comparing them to three controls: a random/constant baseline, a deterministic pulse‑rate‑variability feature set, and a generic time‑series foundation model (MOMENT). Results show that over a third of task‑regime combinations yield no advantage for any PPG foundation model over the baseline, and in most cases no PPG‑specific model outperforms the simple controls, indicating that current PPG foundation models lack generalised, transferable representations.
By Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
The Cross-View Attention Fusion Network (CVAF‑Net) is a dual‑view deep learning model that estimates cardiac output from short photoplethysmography (PPG) segments by combining raw PPG signals with a structured prior‑guided feature sequence map through cross‑view attention. Evaluated on simulated, vasoconstriction, and real‑world activity datasets, CVAF‑Net achieved a mean absolute error of 0.19 L/min on simulated data and as low as 1.20 L/min in real settings, outperforming most benchmarks while reducing computational cost by twelvefold compared to a leading Transformer model. Plausibility checks confirmed physiologically consistent correlations with age, heart rate, and systemic vascular resistance.
By Yaowen Zhang, Bo Cui, Libera Fresiello, Peter H. Veltink, Dirk W. Donker, Ying Wang
The paper introduces a fluctuation‑aware evaluation framework for photoplethysmography (PPG)‑based blood pressure (BP) estimation that uses time‑series change‑point detection to identify abrupt BP shifts, rather than relying on arbitrary BP thresholds. It demonstrates that state‑of‑the‑art models suffer significant performance drops around these change points and that periodic test‑time calibration is inadequate. To mitigate this, the authors propose a targeted re‑calibration strategy triggered by detected change points, improving robustness without altering model architectures.
By Yunwon Tae, Minje Park, Gyunho Rho, Dongjoon Yoo, Sunghoon Joo
The paper introduces a fluctuation‑aware evaluation framework for photoplethysmography (PPG)‑based blood pressure (BP) estimation that uses time‑series change‑point detection to identify abrupt BP shifts, rather than relying on simple BP thresholds. It demonstrates that many state‑of‑the‑art models degrade significantly around these change points and that periodic test‑time calibration is inadequate. To mitigate this, the authors propose a targeted re‑calibration strategy triggered by detected change points, improving robustness without altering model architectures.
The study evaluates how acquisition context and photoplethysmography (PPG) signals contribute to session‑calibrated blood pressure tracking using a wearable‑state model on 653 AuroraBP participants. Adding contextual information reduced mean absolute errors (MAEs) for systolic and diastolic BP by 0.436 mmHg and 0.126 mmHg, respectively, while PPG alone provided modest improvements. Exploratory follow‑ups with sensor‑history ensembles and pulse‑rate fusion yielded only slight gains, and a separate intraoperative model (VitalDB) showed limited PPG benefit.
By Farouk Ganiyu Adewumi, Timothy Oladunni
The paper introduces Phy‑BP, a physics‑constrained deep learning framework for contactless blood pressure monitoring using triaxial bodyseismography (BSG). It employs an adaptive quality‑control algorithm to select cardiogenic‑rich BSG segments and embeds a 3‑D wave‑propagation physical model into the neural network to align multi‑axis features, enhancing robustness to real‑world distortions. Experiments on a 162‑hour hospital dataset from 21 subjects demonstrate that Phy‑BP can filter low‑quality measurements and maintain accurate BP estimation even with limited training data.
By Yuanyuan Zhang, Yida Zhang, Jiahui Li, Yuyan Wu, Fei Dou, Xiao Yin, Zhenlin An, Hae Young Noh, Wenzhan Song