arXiv:2606. 11125v1 Announce Type: cross Abstract: Blood pressure (BP) is a key marker for cardiovascular risk assessment and therapeutic decision-making, and Photoplethysmography (PPG) enables low-cost, wearable-friendly cuffless BP estimation.
By Yidan Shen, Neville Mathew, Maham Rahimi, Deependra Dhakal, George Zouridakis, Xin Fu, Renjie Hu
arXiv:2606. 15284v1 Announce Type: cross Abstract: Photoplethysmography (PPG) plays a central role in wearable health monitoring and clinical decision support.
By Chenyang He, Xinyi Shao, Shun Huang, Bosong Huang, Daoqiang Zhang, Ming Jing, Cheng Ding
arXiv:2607. 23406v1 Announce Type: cross Abstract: Continuous cuffless blood pressure (BP) monitoring is essential for connected health systems and wearable devices, enabling early detection, longitudinal tracking, and personalized management of cardiovascular disease.
By Bo Wu, Haoling Wang, Zhuodiao Kuang, Kateryna Shapovalenko
arXiv:2608. 14656v1 Announce Type: cross Abstract: Photoplethysmography (PPG) is widely used in consumer wearables because of its low cost and ease of acquisition.
By Zhongli Wu, Zhuangzhi Gao, He Zhao, Feixiang Zhou, Fu Wang, Jinru Ding, Yuankai Wang, Hongyi Qin, Gregory Y. H. Lip, Bil Kirmani, Yalin Zheng
arXiv:2606. 07365v1 Announce Type: cross Abstract: Photoplethysmography (PPG), a non-invasive measure of changes in blood volume, is widely used in both wearable devices and clinical settings.
By Eloy Geenjaar, Vince Calhoun, Scott Daly, Gouthaman KV, Lie Lu, Trisha Mittal, Daniel P. Darcy
arXiv:2608. 05893v1 Announce Type: new Abstract: Electrocardiography (ECG) is one of the most widely used non-invasive tools for diagnosing cardiovascular disease, but transforming multi-lead ECG recordings into reliable clinical reports remains challenging.
By Akanta Das, Tasinul Islam Ahon, Ahmed Mahir Sultan Rumi, Md Mahbubur Rahman, Tausif Amim Shadly, Tanzima Hashem
The study develops a 1‑D ResNet classifier that uses a fixed 17‑channel hemodynamic representation derived from photoplethysmography (PPG) to predict in‑hospital stroke risk states up to six hours before clinical recognition. Using data from MIMIC‑III and MC‑MED, the model achieved F1‑scores ranging from 0.7956 to 0.9888 across 4‑, 5‑, and 6‑hour horizons, outperforming four non‑waveform clinical and structured‑EHR comparators in all cohort‑horizon settings. Retrospective analysis showed that the PPG model’s false‑positive rates on high‑risk non‑stroke controls could be reduced through persistence aggregation, though the study does not establish a calibrated bedside alarm or a clinically validated prediction lead time.
By Jiaming Liu, Cheng Ding, Jian Wu, Hongxia Xu, Daoqiang Zhang
arXiv:2609.13190v1 Announce Type: new
Abstract: Continuous cuffless blood pressure (BP) monitoring using photoplethysmography (PPG) offers a promising solution for personalized healthcare. However, e...
By Myung-Kyu Yi, Jongshill Lee, Jeyeon Lee, In Young Kim
arXiv:2607. 15721v1 Announce Type: new Abstract: Cardiometabolic diseases remain among the most persistent drivers of preventable morbidity because diabetes, hypertension, and cardiovascular disease frequently co-occur and share metabolic, vascular, demographic, and behavioral determinants.
By S M Asif Hossain, Ruksat Khan Shayoni, M. F. Mridha, Jungpil Shin
The study investigates how adding ballistocardiography (BCG) signals to photoplethysmography (PPG) and arterial pressure wave (APW) signals affects the estimation of cardiovascular biomarkers. Using a unified whole‑body cardiovascular model, synthetic PPG, APW, and BCG signals were generated and analyzed with neural posterior estimation and simulation‑based inference. Results show that incorporating BCG significantly improves estimation accuracy, converting multimodal posterior distributions from PPG/APW alone into unimodal distributions, thereby enhancing the reliability of cardiovascular biomarker estimation.
By Shusaku Maeda, Masahiro Nakano, Tomoharu Iwata, Kenji Komiya, Ryo Nishikimi, Kunio Kashino
arXiv:2608. 12944v1 Announce Type: new Abstract: Electrocardiography (ECG), photoplethysmography (PPG), and phonocardiography (PCG) provide complementary views of the same cardiac cycle, yet existing cardiac foundation models are trained for a single sensing modality, leaving the shared physiology across sensors unexploited.
By Hamza Shafiq, Hung Manh Pham, Bin Zhu, Pan Zhou, Jun Hu, Aaqib Saeed
arXiv:2607. 01145v1 Announce Type: new Abstract: Data analysis in the medical domain often encounters scenarios involving a limited target dataset and a large, unannotated dataset with a general distribution.
By Siwon Kim