arXiv:2607. 05317v2 Announce Type: replace-cross Abstract: Automated detection of intracranial aneurysms (IAs) from CT angiography (CTA) is severely hindered by high false-positive rates.
By Akshay Gokhale, Mansi Dhamne
arXiv:2312. 17670v5 Announce Type: replace-cross Abstract: The Circle of Willis (CoW) is an important network of arteries connecting major circulations of the brain.
By Kaiyuan Yang, Fabio Musio, Yihui Ma, Norman Juchler, Johannes C. Paetzold, Rami Al-Maskari, Luciano H\"oher, Hongwei Bran Li, Ibrahim Ethem Hamamci, Anjany Sekuboyina, Suprosanna Shit, Houjing Huang, Chinmay Prabhakar, Ezequiel de la Rosa, Bastian Wittmann, Diana Waldmannstetter, Florian Kofler, Fernando Navarro, Martin J. Menten, Ivan Ezhov, Daniel Rueckert, Iris N. Vos, Ynte M. Ruigrok, Birgitta K. Velthuis, Hugo J. Kuijf, Pengcheng Shi, Wei Liu, Ting Ma, Maximilian R. Rokuss, Yannick Kirchhoff, Fabian Isensee, Klaus Maier-Hein, Chengcheng Zhu, Huilin Zhao, Philippe Bijlenga, Julien H\"ammerli, Catherine Wurster, Laura Westphal, Jeroen Bisschop, Elisa Colombo, Hakim Baazaoui, Hannah-Lea Handelsmann, Andrew Makmur, James Hallinan, Amrish Soundararajan, Benedikt Wiestler, Jan S. Kirschke, Evamaria O. Riedel, Roland Wiest, Emmanuel Montagnon, Laurent Letourneau-Guillon, Kwanseok Oh, Dahye Lee, Orhun Utku Aydin, Adam Hilbert, Jana Rieger, Dimitrios Rallios, Satoru Tanioka, Alexander Koch, Dietmar Frey, Abdul Qayyum, Moona Mazher, Steven Niederer, Nico Disch, Julius C. Holzschuh, Dominic LaBella, Francesco Galati, Daniele Falcetta, Maria A. Zuluaga, Chaolong Lin, Haoran Zhao, Zehan Zhang, Minghui Zhang, Xin You, Hanxiao Zhang, Guang-Zhong Yang, Yun Gu, Sinyoung Ra, Jongyun Hwang, Hyunjin Park, Junqiang Chen, Marek Wodzinski, Henning M\"uller, Nesrin Mansouri, Florent Autrusseau, Cansu Yalcin, Rachika E. Hamadache, Clara Lisazo, Joaquim Salvi, Adri\`a Casamitjana, Xavier Llad\'o, Uma Maria Lal-Trehan Estrada, Valeriia Abramova, Luca Giancardo, Arnau Oliver, Paula Casademunt, Adrian Galdran, Matteo Delucchi, Oscar Camara, Jialu Liu, Haibin Huang, Yue Cui, Zehang Lin, Yusheng Liu, Shunzhi Zhu, Tatsat R. Patel, Adnan H. Siddiqui, Vincent M. Tutino, Maysam Orouskhani, Huayu Wang, Mahmud Mossa-Basha, Yuki Sato, Sven Hirsch, Susanne Wegener, Bjoern Menze
X‑LMC is a spatiotemporal deep‑learning framework that automatically scores leptomeningeal collateral (LMC) status from time‑resolved biplane digital subtraction angiography (DSA). It uses a DINOv2 backbone to encode spatial frames, a token‑level cross‑view attention module to fuse orthogonal projections, and a recurrent network to model contrast bolus dynamics. On a multicenter dataset of 134 M1‑segment occlusion patients, X‑LMC achieved a Quadratic Weighted Kappa of 0.398 and a macro‑F1 of 0.711, outperforming static and other spatiotemporal baselines and matching clinical inter‑rater agreement.
arXiv:2608. 19965v1 Announce Type: cross Abstract: Segmentation of curvilinear anatomical structures in 3D medical images remains challenging due to complex topology, severe class imbalance, weak contrast, and large variations in structure morphology.
By Sidi Mohamed Sid'El Moctar, Nicolas Vitry, H\'el\`ene Bouvrais
arXiv:2608. 19769v1 Announce Type: cross Abstract: Fast and accurate segmentation of Acute Ischemic Stroke (AIS) lesions is essential for stroke prognosis and treatment planning.
By Maunil Shah, Vaanathi Sundaresan
arXiv:2606.26706v2 Announce Type: replace
Abstract: Intracranial aneurysms are often asymptomatic until rupture, which carries high mortality. Rupture risk assessment and treatment planning depend on...
By Pengcheng Shi, Kaiyuan Yang, Houjing Huang, Jiawei Chen, Yan Lu, Jiaqi Liu, Murong Xu, Minghui Zhang, Bjoern Menze, Xinglin Zhang
arXiv:2610.20509v1 Announce Type: cross
Abstract: Generative super-resolution (SR) can recover sharp detail in computed tomography (CT) images from severely downsampled observations, but the missing...
By Hairong Ni, Jiahe Huang, Minghao Guo, Wojciech Matusik, Rose Yu
Accurate coronary Digital Subtraction Angiography (DSA) vessel segmentation is essential for computer-aided diagnosis and treatment planning of coronary artery disease (CAD). However, thin low-contrast vessels, background interference, and severe vessel-background class imbalance make reliable segmentation of weak distal branches and vessel boundaries challenging.
The paper introduces a geometry‑guided sampling operator that directs feature sampling rather than altering convolution kernels in 3D encoder‑decoder networks. By predicting local orientations and bounded step sizes, the operator samples symmetrically around each voxel, generating compact geometric and boundary cues that improve fine‑structure segmentation. Replacing stride‑1 and stride‑2 operations in a 3D U‑Net yields consistent gains on BraTS, MSD Hepatic Vessel, and TDSC‑ABUS datasets, with better boundary metrics and fewer parameters, and the operator can be integrated into other backbones without architectural changes.
By Sizhe Wang, Himashi Peiris, Zhaolin Chen
arXiv:2610.34529v1 Announce Type: cross
Abstract: Background/Objectives: Rapid differentiation of ischemic and hemorrhagic stroke subtypes is vital for acute management. Although current deep learnin...
By Tansel Uyar
The RSNA Intracranial Aneurysm (RSNA-ICA) Dataset is a large, publicly available, expert‑annotated collection of 7202 CTA, MRA, and MRI series from 4278 adult patients across 21 institutions in 12 countries. It includes 2566 CTA, 2166 MRA, and 2470 MRI series with and without intracranial saccular aneurysms, providing geographic and imaging diversity. Expert annotations mark aneurysm presence, location, and, for 178 series, 3‑D segmentations of vascular locations, and 5041 series are freely available through MIRA for non‑commercial research.
By Maria Correia de Verdier, Rachit Saluja, Jason Sho, Maryam Vabarizad, Rennie Yung-Chieh Chen, Uyen N. T. Nguyen, Mona Alrehaili, Layal Aweidah, Deniz Bulja, Wesley C. Chan, Hernan Chaves, Madhavi Duvvuri, Huseyin Ekin Ergin, Undrakh-Erdene Erdenebold, Ekim Gumeler, Mohamed Sobhi Jabal, Chin-Chi Kuo, Fatima Mubarak, Sevde Nur Emir, Scott Riley K. Ong, Johanna Ortiz, Almudena P\'erez-Lara, Andreas M. Rauschecker, Shayan Sirat Maheen Anwar, Charit Tippareddy, Tam Tran, Sorawis Visrutaratna, John Mongan, Adam E. Flanders, Robyn Ball, Greg Zaharchuk, Peter D. Chang, Felipe Kitamura, Errol Colak, Luciano Prevedello, Tyler Richards, Data Contributor Group, Dataset Annotator Group, Evan Calabrese, Jeffrey D. Rudie
arXiv:2607. 22139v1 Announce Type: cross Abstract: Accurate pixel-level classification of coronary angiograms is critical for cardiovascular disease assessment, yet the field lacks standardized evaluation protocols.
By Dominik Bernard Lau, Hubert Malinowski, Jerzy Szyjut, Adam Brzeski, Tomasz Dziubich, Rados{\l}aw Targo\'nski, Tomasz Figatowski, Natalia Zieli\'nska