arXiv:2608.24281v1 Announce Type: new
Abstract: Reducing annotation requirements remains a key challenge in developing robust medical object detectors. To address this, Vision-Language (VL) object de...
By Sheethal Bhat, Bogdan Georgescu, Awais Mansoor, Mathias Zinnen, Pranjal Sahu, Florin C. Ghesu, Sasa Grbic, Andreas Maier
arXiv:2606. 19460v1 Announce Type: cross Abstract: We introduce the first generative foundation model for chest radiograph synthesis trained from scratch at the billion-parameter scale.
By Fabio De Sousa Ribeiro, Emma A. M. Stanley, Charles Jones, Tian Xia, Dominic C. Marshall, Laurent Renard Trich\'e, Christopher V. Cosgriff, Panagiotis Dimitrakopoulos, Sotirios A. Tsaftaris, Ben Glocker
arXiv:2607. 23343v1 Announce Type: cross Abstract: Intraoperative 2D/3D registration aligns preoperative CT volumes with intraoperative X-ray or fluoroscopic images and is essential for image-guided interventions.
By Minheng Chen, Youyong Kong
The paper presents the first systematic evaluation of out‑of‑distribution generalization for congenital heart disease (CHD) segmentation, using the ImageCHD cohort as a held‑out target. It compares several segmentation architectures under different training regimes, showing that in‑distribution performance is a poor predictor of cross‑cohort robustness: nnU‑Net drops from 0.77 to 0.51 Dice, while SwinUNETR maintains higher performance at 0.67 Dice. Limited target‑domain adaptation with only 11 labeled ImageCHD cases boosts all SwinUNETR variants above 0.76 Dice, highlighting the importance of explicit cross‑dataset testing.
By Aniketh Vijesh, Shrisharanyan Vasu, Abhijit Ramesh, Clare Pomeroy-Ward, Harikrishnan Anil Maya, Sarin Xavier, Mahesh Kappanayil, Gilad Gressel
arXiv:2601.15891v4 Announce Type: replace
Abstract: Vision-language pretraining has driven progress in medical image representation learning, but it depends on paired image-text data and can inherit...
By Anas Anwarul Haq Khan, Mariam Husain, Pratik Jalan, Kshitij Jadhav
The study benchmarks foundation models for chest X‑ray classification across a domain shift from adult to pediatric patients. Six foundation models and two CNN baselines were evaluated on a harmonized five‑label task using adult data for adaptation and tested on both adult and pediatric sets. Results show all models experience a substantial performance drop—over 10 percentage points—when applied to pediatric data, and deeper adaptation does not markedly improve cross‑population generalization.
By Sara In\'acio, Hugo Proen\c{c}a, Jo\~ao C. Neves
Congenital heart disease (CHD) diagnosis and surgical planning often require patient-specific 3D anatomical models, but manual segmentation is labor-intensive, particularly in complex anatomies. Altho...
arXiv:2607. 02998v1 Announce Type: cross Abstract: Controllable generative models of 3D medical images can synthesize volumes with specified clinical attributes, but this demands samples that are simultaneously high-fidelity, natively 3D, and faithful to the requested conditioning.
By Max Van Puyvelde, Halil Ibrahim Gulluk, Wim Van Criekinge, Olivier Gevaert
arXiv:2610.08813v1 Announce Type: new
Abstract: X-ray image-based Radiology Report Generation (RRG) constitutes a critical research direction within medical artificial intelligence, with great potent...
By Xiao Wang, Yuxiang Zhang, Dan Xu, Yuehang Li, Shiao Wang, Bo Jiang, Yaowei Wang, Yonghong Tian, Jin Tang
arXiv:2607. 02998v2 Announce Type: replace-cross Abstract: Controllable generative models of 3D medical images can synthesize volumes with specified clinical attributes, but this demands samples that are simultaneously high-fidelity, natively 3D, and faithful to the requested conditioning.
By Max Van Puyvelde, Halil Ibrahim Gulluk, Wim Van Criekinge, Olivier Gevaert
arXiv:2606. 01537v1 Announce Type: cross Abstract: Clinical diagnosis often requires combining imaging with physiological measurements, yet deployed models typically operate on unimodal data.
By Yancheng Liu, Kenichi Maeda, Manan Pancholy
Generating CT volumes from MRI and CBCT can improve treatment planning in adaptive radiotherapy while avoiding additional radiation exposure. However, direct regression of CT intensities is challenged by the inherently high dynamic range and long-tailed distributions, thereby averaging out sparse yet clinically important structures.