arXiv Machine Learning

Counterfactual Analysis of Extent Leakage from Annotation-Derived Prompts in Vision-Language Medical Image Segmentation

The paper investigates how text prompts used in vision‑language medical image segmentation models leak information about lesion extent from the training masks. Experiments on colonoscopy, chest X‑ray, and breast ultrasound datasets show that size, count, and location words in captions largely drive segmentation accuracy, with extent leakage accounting for most of the improvement. The authors demonstrate that this leakage can be quantified without training a model and propose an evaluation protocol to separate caption content from label copying.

arXiv Computer Vision
5d ago

Measuring and Attributing Evidence Sensitivity in Medical Vision-Language Models via Symmetric Counterfactual Controls

The paper introduces a Counterfactual Evidence Framework to evaluate medical vision‑language models (VLMs) by pairing lesion erasures with matched control edits, ring controls, and degraded views, thereby separating true visual discrimination from answer‑threshold shifts. Across 507 test cases, frontier VLMs correctly identify 41.1%–61.6% of erased lesions, while a counterfactual‑trained MedScope‑4B model achieves only 9.6%, with physician readers confirming the reliability of automated erasures in colonoscopy. The study also demonstrates that apparent utility gains stem from threshold adjustments rather than improved discrimination, and shows that retraining on pneumothorax cases can detect 53% of new pneumothoraxes without altering main‑test outcomes.

By Bhaskar Gurram
arXiv Computer Vision
Aug 27

Label-Free Foundational Model Selection for Medical Image Classification under Distribution Shift via Pseudo Label Discrepancy

The paper introduces a label‑free method called AURCC for selecting the best foundational model for medical image classification when the target domain lacks labels. AURCC uses a pseudo‑label discrepancy computed by the SUDO framework to score models without fine‑tuning. Experiments on chest X‑ray data across three inter‑hospital shifts show that AURCC closely matches the true model ranking, outperforming simple source‑accuracy baselines especially when source data are limited.

By Juan I\~naki Larrea, Lucas Mansilla, Enzo Ferrante
Hugging Face Trending Papers
Jun 29

SHOVIR: A Benchmark for Evaluating Vision Shortcut Learning in Radiology Report Generation

Current evaluation protocols for Vision-Language Models (VLMs) in Radiology Report Generation (RRG) rely on report-level metrics that measure lexical overlap or aggregate clinical correctness. However, such metrics do not test whether individual diagnostic statements stem from the actual pathological evidence visible in the image.

arXiv AI
Sep 25

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

Med-AR introduces two autoregressive vision‑language models, Med‑AR‑8B and Med‑AR‑2B, pretrained on structured radiology reports, abnormality‑focused text, and region annotations to address long‑tailed chest X‑ray classification. The models outperform existing contrastive, self‑supervised, and supervised encoders—including Med‑CLIP, CheXFound, EVA‑Base, ARK, and BioViL‑T—across PadChest, MIMIC‑CXR, and CheXpert, achieving higher mean AUROC and AUPRC for head, medium, and tail findings and lower excess area under the risk‑coverage curve. Med‑AR also demonstrates improved selective‑prediction performance, with Med‑AR‑8B raising tail‑label mean AUPRC on MIMIC‑CXR from 0.1033 to 0.1441 and Med‑AR‑2B delivering the strongest discrimination on PadChest.

By Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli, Preetham Putha
arXiv Computer Vision
Sep 2

Instance-Guided Report Anchoring for Text-Free 3D Abnormality Segmentation in Chest CT

Instance-Guided Report Anchoring (IGRA) is a model-agnostic module that links each abnormality instance in a chest CT to the corresponding finding in a radiology report during training, while discarding text components at inference. By reformulating free-text grounding as multi-label volumetric segmentation, IGRA allows all abnormality categories to be predicted in a single image-only forward pass. The method improves Dice scores by 22.5% over the strongest image-only baseline and matches state‑of‑the‑art performance on single-finding subsets, with consistent gains across multiple 3D segmentation backbones and datasets.

By Zhenyu Bu, Haoyan Ding, Chushu Shen, Xinyuan Zheng, Peiyu Duan, Xueqi Guo, Sepehr Farhand, Yoshihisa Shinagawa, Gerardo Hermosillo, Chaowei Wu
arXiv Computer Vision
Aug 31

Report Supervision

The paper introduces Report Supervision (R‑Super), a framework that uses radiology reports to supervise tumor segmentation models. By incorporating loss functions that align segmentation outputs with report‑derived tumor counts, sizes, and locations, R‑Super improves detection and segmentation performance. Experiments on kidney and pancreatic tumors show up to a 15% increase in F1‑Score and DSC compared to mask‑only training, outperforming methods like CLIP and multi‑task learning.

By Pedro R. A. S. Bassia, Wenxuan Li, Jakob Wasserthal, Jieneng Chen, Xinze Zhou, Zheren Zhu, Chuntung Zhuanga, Sergio Decherchi, Andrea Cavalli, Kang Wang, Yang Yang, Alan Yuille, Zongwei Zhou