CLARiTy is a vision transformer model that jointly performs multi‑label classification and weakly‑supervised localization of chest X‑ray pathologies. It uses class‑specific tokens to produce attention maps and a SegmentCAM module to refine foreground segmentation with anatomical priors. Trained on NIH ChestXray14 image‑level labels and distilled from a ConvNeXtV2 teacher, CLARiTy achieves competitive classification and strong localization, especially for small pathologies, outperforming prior methods by up to 50.7% relative Macro IoU accuracy.
By John M. Statheros, Hairong Wang, Richard Klein
arXiv:2608.28455v1 Announce Type: new
Abstract: Contrastive vision-language learning uses paired chest CT volumes and radiology reports to learn abnormality classifiers without manually annotated lab...
By Huseyin Umut Isik, Mehmet Alp Ozaydin, Sila Kurugol, \c{S}eyda Ertekin
Instance-Guided Report Anchoring (IGRA) is a model-agnostic module that links each abnormality instance in a chest CT to the corresponding finding in a radiology report during training, while discarding text components at inference. By reformulating free-text grounding as multi-label volumetric segmentation, IGRA allows all abnormality categories to be predicted in a single image-only forward pass. The method improves Dice scores by 22.5% over the strongest image-only baseline and matches state‑of‑the‑art performance on single-finding subsets, with consistent gains across multiple 3D segmentation backbones and datasets.
By Zhenyu Bu, Haoyan Ding, Chushu Shen, Xinyuan Zheng, Peiyu Duan, Xueqi Guo, Sepehr Farhand, Yoshihisa Shinagawa, Gerardo Hermosillo, Chaowei Wu
EXACT is an explainable anomaly‑aware vision foundation model designed for 3D chest CT analysis. It learns spatially resolved representations from 25,692 paired CT scans and radiology reports, jointly performing organ segmentation and multi‑instance anomaly localization without voxel‑level annotations. In multinational, multi‑center studies, EXACT outperformed existing 3D medical foundation models across tasks such as multi‑disease diagnosis, zero‑shot anomaly localization, downstream adaptation, and visually grounded report generation.
By Xuguang Bai, Mingxuan Liu, Tongxi Song, Yifei Chen, Hongjia Yang, Kasidit Anmahapong, Zihan Li, Ying Zhou, Qiyuan Tian
arXiv:2608. 05960v1 Announce Type: cross Abstract: Routine CT interpretation is inherently comprehensive, capturing incidental findings across the entire scan volume.
By Maulik Chevli, Johannes Brandt, Rickmer Braren, Daniel Rueckert, Philip M\"uller
The paper introduces LoG, a localization‑infused vision‑language fusion framework for text‑guided medical image segmentation. LoG jointly performs multi‑scale target localization to explicitly capture target‑oriented semantics and employs three levels of localization‑infused fusion—feature, attention, and loss—to integrate spatial information into segmentation. Experiments on three benchmark datasets across three imaging modalities show that LoG consistently outperforms state‑of‑the‑art methods.
By Songyue Han, Mingye Zou, Shuchang Ye, Lei Bi, Mingyuan Meng
HoloCT is a 3D foundation model that simultaneously performs CT interpretation and voxel‑level segmentation, providing 3D masks as evidence. Trained on HoloDATA, which includes 195,921 CT scans, 6.2 million instruction dialogues, and 2.8 million CT‑mask pairs, it outperformed specialist and foundation models across 346 tasks and in multicentre validation on 11,455 clinical scans. The model demonstrated bidirectional semantic‑spatial synergy, improving both language‑guided segmentation and interpretation performance, and surpassed four radiologists in a retrospective reader study.
By Yulu Xie, Zilong Li, Shen Xu, Yifan Bai, Liuhong Shi, Jiao Chen, Xianglei Kong, Wenchao Zhu, Na Shen, Xianghua Ye, Yang Yan, Jiaju Zheng, Yunsong Peng, Yanzhou Su, Chaohui Yu, Hao Luo, Fan Wang
Vision-language pre-training (VLP) holds great promise for general-purpose medical AI by leveraging radiology reports as rich textual supervision, yet existing methods struggle with 3D CT imaging due to inefficient visual backbones and coarse semantic alignment. To address these issues, we propose a tailored VLP framework featuring three key components: (1) a CNN-ViT hybrid encoder that replaces ViT's patch embedding with a 3D CNN backbone to efficiently capture local anatomical details while preserving global attention and compatibility with pre-trained cross-modal priors; (2) a disease-level contrastive learning mechanism using learnable query tokens to dynamically extract disease-specific semantics from full reports and align them with corresponding visual features, thereby disentangling distinct diseases within the same anatomical region; and (3) a diagnosis-aware prompt strategy that employs real clinical phrases and aggregated disease prototypes to bridge the pre-training-inference gap and enhance zero-shot diagnostic reliability.
arXiv:2607.10851v2 Announce Type: replace
Abstract: Medical image classification models are ideally expected to identify diagnostically relevant regions while making predictions, yet standard classif...
By Tonmoy Hossain, Atiqur Rahman, Farhana Hossain Swarnali, Miaomiao Zhang
arXiv:2608. 13690v1 Announce Type: cross Abstract: Medical image segmentation is still largely treated as a vision-only problem, although clinical interpretation often relies on textual knowledge of anatomy, location, appearance, and surrounding context.
By Rafi Ibn Sultan, Hui Zhu, Chengyin Li, Dongxiao Zhu
XGLASS is a method that transfers expertise from 2D X‑ray vision‑language models to 3D CT volumes by using disease‑conditioned importance maps derived from radiologist gaze on X‑rays. By aligning these gaze priors with coronal CT projections, XGLASS predicts a disease‑specific ordering of axial slices, prioritizing diagnostically relevant slices. The approach achieves a top‑10 hit rate of up to 75.9% on a 240‑slice scan and reduces downstream model calls by 87.5% while improving F1 scores, making it a lightweight preselector for volumetric CT analysis.
By Michael Gl\"ockler, Timo Ropinski
arXiv:2603. 12514v2 Announce Type: replace-cross Abstract: Accurate detection and localization of traumatic injuries in abdominal CT remain challenging because voxel-level annotations are limited and expensive to obtain.
By Shivam Chaudhary, Sheethal Bhat, Andreas Maier