Instance-Guided Report Anchoring (IGRA) is a model-agnostic module that links each abnormality instance in a chest CT to the corresponding finding in a radiology report during training, while discarding text components at inference. By reformulating free-text grounding as multi-label volumetric segmentation, IGRA allows all abnormality categories to be predicted in a single image-only forward pass. The method improves Dice scores by 22.5% over the strongest image-only baseline and matches state‑of‑the‑art performance on single-finding subsets, with consistent gains across multiple 3D segmentation backbones and datasets.
By Zhenyu Bu, Haoyan Ding, Chushu Shen, Xinyuan Zheng, Peiyu Duan, Xueqi Guo, Sepehr Farhand, Yoshihisa Shinagawa, Gerardo Hermosillo, Chaowei Wu
arXiv:2608.00231v2 Announce Type: replace
Abstract: Volumetric CT vision-language pretraining learns 3D representations from scan-report pairs, but global and anatomy-aware objectives supervise only...
By Guoliang You, Haifan Gong, Xiaomeng Chu
DALE-CT introduces depth‑aware 2D slice encoders that learn an anatomical world model of chest CT scans without 3D or positional supervision. By sampling self‑supervised views across a physical $z$‑axis slab, the encoder captures how anatomy changes between neighboring slices, enabling it to recover slice ordering and distinguish slices by anatomy alone. The model, trained on a large 287k‑scan corpus, achieves state‑of‑the‑art performance on CT‑RATE and is released with full code and evaluation tools.
By Evan W. Damron, Mahmut S. Gokmen, Mitchell A. Klusty, Caroline N. Leach, Emily B. Collier, V. K. Cody Bumgardner
Vision-language pre-training (VLP) holds great promise for general-purpose medical AI by leveraging radiology reports as rich textual supervision, yet existing methods struggle with 3D CT imaging due to inefficient visual backbones and coarse semantic alignment. To address these issues, we propose a tailored VLP framework featuring three key components: (1) a CNN-ViT hybrid encoder that replaces ViT's patch embedding with a 3D CNN backbone to efficiently capture local anatomical details while preserving global attention and compatibility with pre-trained cross-modal priors; (2) a disease-level contrastive learning mechanism using learnable query tokens to dynamically extract disease-specific semantics from full reports and align them with corresponding visual features, thereby disentangling distinct diseases within the same anatomical region; and (3) a diagnosis-aware prompt strategy that employs real clinical phrases and aggregated disease prototypes to bridge the pre-training-inference gap and enhance zero-shot diagnostic reliability.
NV-Reason-CT is a generative vision‑language model designed for chest and abdominal CT analysis that preserves native 3D visual encoding and incorporates radiologist‑guided reasoning. The system couples a 3D vision transformer with a language model, feeding all visual tokens and their 3D coordinates directly into language decoding to maintain volumetric spatial information. Trained on a curated corpus of about 550,000 multimodal instruction examples, the model supports abnormality classification, report generation, and interactive reasoning, achieving strong performance on CT benchmarks and reducing expert interpretation time by 50%.
By Andriy Myronenko, Dong Yang, Yucheng Tang, Baris Turkbey, Benjamin Simon, Stephanie Harmon, Rikhil Makwana, Mariam Aboian, Sena Azamat, Ibrahim Ethem Hamamci, Sezgin Er, Bjoern Menze, Marc Edgar, Yufan He, Pengfei Guo, Daguang Xu
arXiv:2607. 27154v1 Announce Type: cross Abstract: CT vision-language foundation models have demonstrated promising performance across downstream tasks, but are typically trained with whole-volume representations that dilute fine-grained anatomical signals.
By Roshan Kenia, Stephanie L McNamara, William Lotter
arXiv:2606. 16991v1 Announce Type: cross Abstract: Multiphasic contrast-enhanced CT (CECT) is widely used for abdominal lesion characterization, yet it carries inherent risks of contrast-induced nephropathy, escalates acquisition burden, and heavily contributes to radiologist workload.
By Mariam Elbakry, Aliaa Sayed Sheha, Salma Hassan Tantawy, Aya Yassin, Concetto Spampinato, Karim Lekadir, Xiaomeng Li, Marawan Elbatel
arXiv:2608. 05960v1 Announce Type: cross Abstract: Routine CT interpretation is inherently comprehensive, capturing incidental findings across the entire scan volume.
By Maulik Chevli, Johannes Brandt, Rickmer Braren, Daniel Rueckert, Philip M\"uller
The paper identifies a representational bottleneck in 3D CT embeddings that limits pathology coverage in automated radiology reports. It introduces AdaRAG-CT, an adaptive retrieval-augmented framework that supplements visual features with controlled textual retrieval to improve report generation. On the CT-RATE benchmark, AdaRAG-CT achieves state‑of‑the‑art clinical efficacy, raising Clinical F1 from 0.420 to 0.480.
By Renjie Liang, Yiling Ma, Yang Xing, Zhengkang Fan, Jinqian Pan, Chengkun Sun, Li Li, Kuang Gong, Jie Xu
arXiv:2607. 25164v1 Announce Type: cross Abstract: A CT examination captures multiple organs, but many biomedical questions concern abnormalities, prognosis, or longitudinal change in a specific organ.
By Zhixuan Ge, Anqi Li, Sadeer Al-Kindi, Hanwen Xu, Wei Qiu
arXiv:2607. 27154v2 Announce Type: replace-cross Abstract: CT vision-language foundation models have demonstrated promising performance across downstream tasks, but are typically trained with whole-volume representations that dilute fine-grained anatomical signals.
By Roshan Kenia, Stephanie L McNamara, William Lotter
arXiv:2606. 03180v1 Announce Type: cross Abstract: Vision-language models (VLMs) for radiology have emerged as a scalable paradigm by leveraging image-report pairs naturally produced in clinical workflows.
By Jonggwon Park, Seongeun Lee, Junhyun Park, Hannah Yun, Hyunwoong Kim, Sohyun Jeong, Hyewon Kang, Byungmu Yoon, Kyoyun Choi