A patient who has lost part of the skull vault needs an implant that fits the defect exactly, and such implants are still drawn by hand in CAD by specialists, which makes each case slow and expensive....
The paper introduces OsteoOpt++, an image‑to‑decision loop that uses pre‑operative CT scans to build a personalized digital twin of a patient’s mandible and then applies Bayesian optimization to adjust six surgical variables for improved bone‑union propensity at the donor‑host interface. In both generic defect models and patient‑specific cases, the optimized plans increased donor‑mandible apposition by up to 29 % and 26 % respectively compared to surgeon‑generated plans, and the predicted apposition closely matched year‑1 bone formation (Dice overlap 70–85 %). The study demonstrates the feasibility of using apposition‑derived predictions to evaluate and compare reconstruction options and provides open‑source code for further development.
By Hamidreza Aftabi, John E. Lloyd, Amanda Ding, Benedikt Sagl, Eitan Prisman, Antony Hodgson, Sidney Fels
arXiv:2608.22131v1 Announce Type: cross
Abstract: Craniosynostosis severity analysis increasingly relies on statistical shape models (SSMs) to quantify cranial morphology, but most existing workflows...
By Sanjay Bhandari, Nawazish Khan, Alzbeta Novotna, Tiffany Jeong, Loretta Bowman, Michael Hernandez, Tobi Somorin, Viraj Govani, Jesse Goldstein, Shireen Elhabian
arXiv:2601. 02088v3 Announce Type: replace Abstract: Orthognathic surgery repositions jaw bones to restore occlusion and enhance facial aesthetics.
By Jiahao Bao, Huazhen Liu, Yu Zhuang, Leran Tao, Xinyu Xu, Yongtao Shi, Mengjia Cheng, Yiming Wang, Congshuang Ku, Ting Zeng, Yilang Du, Siyi Chen, Shunyao Shen, Suncheng Xiang, Hongbo Yu
VoxelSynth3D is a training‑free 3D image‑domain framework that reduces metal artifacts in postoperative musculoskeletal CT by combining support masking, normalized tissue synthesis, deviation gating, and restricted edge refinement. The method preserves implant voxels while correcting surrounding tissue artifacts and was evaluated on a newly constructed Synthetic CLINIC‑Metal benchmark, showing a reduction in RMSE from 801.48 to 786.18 HU on 40 held‑out cases. Compared to a 3D Gaussian smoother, VoxelSynth3D achieved a 13.58 HU improvement and maintained clean-edge agreement beyond 5 mm from metal.
By Amritesh Banerjee, Abdul Basit, Renil Renji Joseph, Nouhaila Innan, Muhammad Shafique
EviDent-CBCT is a framework that generates dental cone‑beam CT reports from limited clinical data by first extracting a discrete record of tooth‑level, global, and tooth‑IAC evidence using an anatomy‑aware network. The evidence is reconciled through a dental‑logic consistency projection before being rendered into a report by a deterministic renderer and an image‑blind language model. The system achieves higher evidence set‑F1 and logical‑F1 scores than baselines and ranked highly in the ODIN 2026 challenge, demonstrating the effectiveness of a discrete evidence record for auditable CBCT report generation.
By Ruiyang Hao, Zhi Qin Tan, Yulan He, Owen Addison, Yunpeng Li
arXiv:2608.24422v1 Announce Type: new
Abstract: Recovering the full 3D spine anatomy from intraoperative ultrasound is an ill-posed inverse problem, as the complete structure must be inferred from in...
By Miruna-Alexandra Gafencu, Vlad Bratulescu, Yordanka Velikova, Mohammad Farid Azampour, Nassir Navab
arXiv:2608. 19932v1 Announce Type: new Abstract: Public cardiac cohorts annotate different subsets of the heart, so shapes from separate sources cannot be pooled without shared correspondence.
By Matej Gazda, Jakub Gazda, Juraj Gazda, Peter Drotar
arXiv:2609.13237v1 Announce Type: cross
Abstract: Orthodontic report generation from intraoral data is normally cast as multimodal captioning, yet the released Bite2Text scan pairs are supplied alrea...
By Ajo Babu George, Govind Arun, Sidharth N Krishna, Uma Ranjan
arXiv:2608.21482v1 Announce Type: cross
Abstract: Background: Multimodal fracture classifiers may benefit from patient and anatomical metadata, but they can also become brittle when contextual inform...
By Musa Tur Farazi, K G Subarno Bithi
The paper presents a closed‑loop system for registering segmented CT fracture fragments to fluoroscopy, providing calibrated uncertainty bounds and flagging implausible or ambiguous fragments. After each shot, the system updates all fragment registrations, stops or plans the next view based on whether new views keep fragment positions within their bounds, and uses uncertainty‑driven planning to reduce the number of shots needed. Experiments on simulated fluoroscopy of 60 held‑out pelvic fractures show that 95% of the bounds cover 83% of unflagged fragments, with 91% of those within 5 mm, and that a simple rule requiring no fragment to move beyond its bound reduces false stops from 23% to 6% at a 2 mm threshold.
"whyItMatters":"The study demonstrates that calibrated uncertainty and view‑planning can make multi‑fragment 2D/3D registration reliable enough to guide pelvic fracture surgery, potentially improving surgical accuracy and efficiency."
By Bowen Xiang, Michael I. Miga
The paper investigates how to keep cosmetic surgery previews confined to the intended facial region when using commercial image‑editing APIs that lack internal controls. By applying a client‑side masked composite—cutting the edited area from the API output and pasting it back onto the original image using a landmark‑derived mask—the authors demonstrate improved localization on synthetic faces compared to prompt‑only edits. Across 15 faces, the masked approach increased localization by a median of 0.315 while largely preserving the desired changes and identity.
By Sukhrobbek Ilyosbekov