arXiv:2607. 12175v1 Announce Type: cross Abstract: X-ray tomography enables nondestructive characterization of material microstructures, while advances in micro-CT imaging have accelerated volumetric data acquisition and reconstruction.
By Pradyumna Elavarthi, Arun J. Bhattacharjee, Harrison Lisabeth, Anca Ralescu, Petrus H. Zwart, Dilworth Parkinson, Elizabeth G. Clark
arXiv:2602.08727v2 Announce Type: replace-cross
Abstract: Undersampled CT volumes minimize acquisition time and radiation exposure but introduce artifacts degrading image quality and diagnostic utili...
By Johannes Thalhammer, Tina Dorosti, Sebastian Peterhansl, Daniela Pfeiffer, Franz Pfeiffer, Florian Schaff
arXiv:2602. 21987v3 Announce Type: replace-cross Abstract: Low-dose CT images are essential for reducing radiation exposure in cancer screening, pediatric imaging, and longitudinal monitoring protocols, but their quality is often degraded by noise from low-dose acquisition, patient motion, or scanner limitations, affecting both clinical interpretation and downstream analysis.
By Jitindra Fartiyal, Pedro Freire, Sergei K. Turitsyn, Sergei G. Solovski
arXiv:2606. 16212v1 Announce Type: cross Abstract: Sparse-view CT reduces radiation dose and scanning time by acquiring fewer projection views, but angular undersampling makes reconstruction severely ill-posed, causing streak artifacts, structural blurring, and loss of fine details.
By Jigang Duan, Jiayi Wang, Heran Wang, Ping Yang, Genwei Ma, Xing Zhao
arXiv:2606. 00146v1 Announce Type: cross Abstract: Motion artifacts in magnetic resonance imaging (MRI) degrade diagnostic reliability.
By Honglin Xiong, Yuxian Tang, Feng Li, Yulin Wang, Lei Xiang, Dinggang Shen, Qian Wang
arXiv:2608. 15246v1 Announce Type: cross Abstract: Sparse-view computed tomography (CT) reduces radiation dose by acquiring fewer projection views, but the resulting inverse problem is highly ill-posed and often produces severe streak artifacts.
By Tran Xuan Hieu Le, Doanh C. Bui, Vu Trung Duong Le, Hoai Luan Pham, Khang Nguyen, Mai K. Nguyen, Tu Bao Ho, Yasuhiko Nakashima
arXiv:2508. 05321v4 Announce Type: replace-cross Abstract: Assume you encounter an inverse problem that shall be solved for a large number of data, but no ground-truth data is available.
By Laura Hellwege, Johann Christopher Engster, Moritz Schaar, Thorsten M. Buzug, Maik Stille
arXiv:2608. 02869v1 Announce Type: new Abstract: Ptychography neural networks suffer from scaling inconsistencies when generalizing out of distribution, limiting their real world viability.
By Albert Vong, Steven Henke, Oliver Hoidn, Hanna Ruth, Junjing Deng, Apurva Mehta, David Shapiro, Alexander Hexemer, Nicholas Schwarz
arXiv:2609.13969v1 Announce Type: new
Abstract: Ptychographic phase reconstruction is commonly formulated as an iterative inverse problem, requiring repeated object-probe updates and resulting in sub...
By Wen-Chun Lin, Yu-Chee Tseng, Jen-Jee Chen, Nan-You Chen
arXiv:2606. 09953v1 Announce Type: cross Abstract: Head computed tomography (CT) typically uses sub-millimeter in-plane resolution but 2-5 mm through-plane spacing, creating substantial anisotropy that degrades multiplanar reconstructions, volumetric measurements such as hematoma volume estimation, and downstream algorithms that assume near-isotropic voxels.
By Luis Cort\'es Ferre, Miguel A. Guti\'errez-Naranjo, Marcin Balcerzyk
arXiv:2609.22849v1 Announce Type: new
Abstract: In novel view synthesis and Computed Tomography (CT) reconstruction with sparse-view X-ray imaging, insufficient angular coverage leads to structural a...
By Lifeng Xing, Dequan Jin, Kunpeng Bu, Peigeng He, Shihui Ying
The paper introduces a one‑pass conditional 3D rectified flow (3D Flow) framework for denoising whole‑body PET images, employing an optimized non‑uniform sampling strategy and a linear‑interpolant velocity‑matching objective. It reconstructs a full 3D volume in about 30 seconds, dramatically faster than multi‑hour 3D diffusion models, while maintaining high global image quality and lesion conspicuity even at ultra‑low doses (down to 1/100 of standard). Zero‑shot transfer tests on independent clinical data demonstrate robust performance across datasets and unseen dose levels.
By Jiale Shen, Guolin Wang, Chenhao Wang, Xinhui Su, Wei Luo, Feng Yu