Validation of HRV Studio: A Transparent and Quality-Control-Aware Platform for Heart Rate Variability Analysis
Read the original on arXiv Machine Learning →The Flow has not summarised this story yet — read it at arXiv Machine Learning.
The Flow has not summarised this story yet — read it at arXiv Machine Learning.
arXiv:2606. 26816v1 Announce Type: new Abstract: Heart Rate Variability (HRV) analysis is a key indicator of cardiac physiological state and aids in disease diagnosis.
ARTA is a graph‑based combinatorial framework that improves interbeat interval estimation from wearable ECG by integrating candidates from multiple detectors into a directed acyclic graph. It uses detector agreement, ECG quality, and history‑dependent transition costs to select a coherent heartbeat sequence via beam‑search dynamic programming, effectively suppressing false detections and recovering missed beats. On benchmark datasets, ARTA reduces heart‑rate mean absolute error by 54% compared to the best single detector and achieves high accuracy in R‑peak detection and IBI estimation while remaining lightweight and training‑free.
arXiv:2608. 00058v1 Announce Type: cross Abstract: Accurate measurement of ECG intervals, including PR, QRS duration, and QT/QTc, is central to cardiac diagnosis, yet the published ECG delineation literature evaluates performance almost exclusively as fiducial-point timing errors on small curated databases, rather than as clinical interval accuracy on large unselected cohorts.
arXiv:2608. 07759v1 Announce Type: cross Abstract: Cardiovascular AI models can classify clean elec- trocardiogram (ECG) signals, but real wearable signals change because of motion, breathing, posture, sensor contact, and true clinical deterioration.
PPG-Bench is an open‑source benchmark that evaluates five publicly available photoplethysmography (PPG) foundation models across nine datasets and 26 tasks, covering cardiovascular state estimation, activity, sleep, screening, and identification. The benchmark tests models under four downstream regimes—linear probing, random forests, frozen MLP probes, and end‑to‑end finetuning—while also comparing them to three controls: a random/constant baseline, a deterministic pulse‑rate‑variability feature set, and a generic time‑series foundation model (MOMENT). Results show that over a third of task‑regime combinations yield no advantage for any PPG foundation model over the baseline, and in most cases no PPG‑specific model outperforms the simple controls, indicating that current PPG foundation models lack generalised, transferable representations.
arXiv:2608. 03597v1 Announce Type: new Abstract: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and is associated with increased risks of stroke, heart failure, and mortality.