arXiv:2607. 20136v1 Announce Type: cross Abstract: Slice-to-volume reconstruction (SVR) is the standard method for obtaining high-resolution (HR) 3D fetal brain volumes from motion-corrupted 2D MRI slice stacks acquired in multiple orientations.
By Busra Bulut, Maik Dannecker, Thomas Sanchez, Sara Neves Silva, Steven Jia, Jean-Baptiste Ledoux, Leo Pomar, Joanna Sichitiu, Yvan Gomez, Meriam Koob, Vincent Dunet, Maria Deprez, Guillaume Auzias, Francois Rousseau, Jana Hutter, Daniel Rueckert, Meritxell Bach Cuadra
UltraDiff is a modular framework that extends differentiable rendering to medical ultrasound by modeling image formation as a path‑space integral gated by travel time. It derives a Monte Carlo estimator for both the forward ultrasound model and its gradients, enabling gradient‑based optimization of scene parameters. The authors demonstrate the method on inverse geometry estimation, recovering vertebral surfaces from simulated and real B‑mode sweeps without requiring pre‑segmented images, achieving competitive geometric accuracy.
By Felix Duelmer, Magdalena Wysocki, Nassir Navab, Mohammad Farid Azampour
arXiv:2605.12567v3 Announce Type: replace-cross
Abstract: The inherent electronic noise, side lobes, and speckle noise complicate clinical interpretation of ultrasound images. Conventional denoising...
By Jiajing Zhang, Bingze Dai, Xi Zhang, Yue Xu, Wei-Ning Lee
arXiv:2608.29820v1 Announce Type: new
Abstract: Ultrasound B-mode imaging commonly suffers from speckle noise and artifacts, requiring a delicate balance between contrast, resolution, and preservatio...
By Juneyong Lee, Jaeyoung Choi
The study introduces a voxel-spacing-aware radiomic framework that incorporates physical geometry into texture computation without resampling, modifying PyRadiomics to preserve native image signals. Four extraction configurations—native non-resampled (NR), isotropic resampling (RS), voxel-spacing-aware (VS), and fake-isotropic preprocessing (FK)—were compared across 685 CT pulmonary nodules and 209 MRI breast cases, evaluating 196 radiomic descriptors. Results show that VS closely matches NR (median ICC(A,1) ≈0.998) while RS and FK exhibit lower agreement, indicating that spacing metadata alone can significantly influence radiomic features.
By David Corral Fontecha, Juan Miranda Bautista, Pablo Menendez Fern\'andez-Miranda, Sergio Rubio-Mart\'in, Lara Lloret Iglesias, Jose A. Vega
FETALFusion is a dual‑path CNN‑Mamba encoder‑decoder designed for fetal head segmentation in 2D ultrasound across transabdominal and transperineal acquisition types. It uses four‑directional state‑space scans at the highest‑resolution stages, domain‑specific channel gates, and a weak landmark shape prior, achieving a Dice score of 0.963 and an HD95 of 2.10 mm on a held‑out test set of 471 images. Ablation studies show that the landmark prior and domain gates drive most of the performance gains, while the state‑space branch has minimal impact.
whyItMatters":"The method provides highly accurate fetal head segmentation without test‑time augmentation or domain labels, enabling reliable head circumference measurement for monitoring fetal growth."
By Ammar Bhilwarawala, Mainak Bandyopadhyay