arXiv AI By Marcelo Nogueira, Jorge H. Oliveira, Carlos F. Ferreira, Miguel T. Coimbra, Al\'ipio M. Jorge

Selection of Heart Sound Segments for Synchronous Classification of Multi-channel Heart Sounds

Read the original on arXiv AI →

The Flow has not summarised this story yet — read it at arXiv AI.

arXiv AI
Nov 5

ENACT-Heart -- ENsemble-based Assessment Using CNN and Transformer on Heart Sounds

ENACT-Heart is a two‑branch ensemble model for classifying heart sounds, combining a Vision Transformer that processes spectrogram images with a convolutional neural network that analyzes waveform visualizations and spectral centroids from the same recordings. The predictions from both branches are fused using a weighted average with fixed, input‑independent weights. On the PASCAL heart‑sound dataset, the ensemble achieved 97.52% accuracy, outperforming the individual ViT (93.88%) and CNN (95.45%) branches, and also delivered a macro‑F1 of 0.94 and a recall of 0.74 for extra heart sounds.

By Jiho Han, Adnan Shaout
arXiv Computer Vision
6d ago

Strong Fused Performance Can Mask Branch Collapse in a Dual-View Heart-Sound Classifier: A Three-Part Diagnostic Protocol

Fusion models are often evaluated solely on their combined score, assuming each branch contributes meaningfully. In a dual‑view heart‑sound classifier (AudioFuse), the spectrogram branch is effectively unused despite strong fused performance, a phenomenon termed branch collapse. The authors propose a three‑part diagnostic—branch deletion impact, linear probing versus an untrained copy, and single‑branch training—to detect such collapse, and find that while the branch can learn its view alone, it is ignored when jointly trained, likely due to early optimisation imbalance.

By Safayet Khan, Hasan Zohirul Islam, Md. Tauhid Bin Iqbal
arXiv AI
Sep 10

AudioFuse: Unified Spectral-Temporal Learning via a Hybrid ViT-1D CNN Architecture for Robust Phonocardiogram Classification

AudioFuse is a hybrid architecture that jointly learns from spectrograms and raw waveforms to classify phonocardiograms. It combines a wide-and-shallow Vision Transformer for spectral features with a shallow 1D CNN for temporal waveforms, reducing overfitting while capturing complementary information. On the PhysioNet 2016 dataset, AudioFuse achieves a state‑of‑the‑art ROC‑AUC of 0.8608 and shows superior robustness to domain shift on the PASCAL dataset, outperforming both spectrogram‑only and waveform‑only baselines.

By Md. Saiful Bari Siddiqui, Utsab Saha