DermaVQA-DAS extends the DermaVQA dataset to include closed‑ended question answering and lesion segmentation for patient‑generated dermatology images. It introduces the Dermatology Assessment Schema (DAS), a structured framework of 36 high‑level and 27 fine‑grained assessment questions with English and Chinese options, and provides expert‑annotated datasets for both tasks. Benchmarking shows that prompt design significantly affects segmentation performance, while state‑of‑the‑art multimodal models achieve strong accuracies on the QA task.
By Wen-wai Yim, Yujuan Fu, Asma Ben Abacha, Meliha Yetisgen, Noel Codella, Roberto Andres Novoa, Josep Malvehy
arXiv:2510.23224v2 Announce Type: replace
Abstract: The rapid digitization of histopathology slides has opened new opportunities for computational tools in clinical and research workflows. Content-ba...
By Hongyi Wang, Zhengjie Zhu, Junlin Hou, Jiabo Ma, Fang Wang, Yue Shi, Qiuyu Cai, Jili Wang, Bo Luo, Zhizhong Chai, Zhengyu Zhang, Li Liang, Xiuming Zhang, Yen-Wei Chen, Lanfen Lin, Hao Chen
arXiv:2608.24688v1 Announce Type: new
Abstract: Precision oncology necessitates a longitudinal model of patient state that captures cancer evolution and treatment over time, integrating multimodal ob...
By Eugene Vorontsov, Yi Kan Wang, Alican Bozkurt, Adam Casson, Ludmila Tydlitatova, Michal Zelechowski, Ezra E. W. Cohen, Jyoti D. Patel, Max Banaszak, Caitlin McWilliams, Shane Colley, Kate Sasser, Ryan Fukushima, Eric Lefkofsky, Razik Yousfi, Siqi Liu
arXiv:2607. 05880v1 Announce Type: cross Abstract: Imaging demand is growing faster than the radiology workforce can expand, and reporting backlogs cannot be resolved through training and recruitment alone.
By Suneeta Mall, Vladimir Nekrasov, Ashnil Kumar, Sajith Karunasena, Aiden Nibali, Alix Bird, Mateo Diaz Shine, Jarrel Seah
The study demonstrates that instruction‑tuning open‑weight large language models (LLMs) with over 500,000 public question‑answer pairs derived from ICD‑10‑GM, ICD‑O‑3, and OPS catalogues markedly improves ICD coding accuracy for German tumor diagnoses. After fine‑tuning, ICD‑10‑GM exact accuracy rose from 1.4–24 % to 41–58 %, and partial accuracy from 31–74 % to 73–83 %. The approach also eliminated malformed code outputs and achieved 99 % tumor‑diagnosis recognition, with performance scaling positively with model size but narrowing the gap between small and large models.
By Stefan Lenz, Lakisha Ortiz Rosario, Georg Vollmar, Arsenij Ustjanzew, Fatma Alickovic, Thomas Kindler, Torsten Panholzer
MultiViewDx is a physician‑validated multimodal instruction dataset that links medical imaging studies with patient context and normalizes heterogeneous reports into an evidence‑linked workflow (evidence → findings → differential discussion → diagnosis). The dataset covers a wide range of imaging modalities and uses a unified image‑text retriever to ensure that instruction synthesis is grounded in source‑supported evidence. Fine‑tuned models on MultiViewDx achieve the highest average accuracy on four MedVQA benchmarks and receive the strongest overall rating on JAMA Clinical Challenge cases, with ablations confirming the importance of case‑level multi‑view organization and evidence‑linked reasoning.
By Junda Wang, Zonghai Yao, Yujan Ting, Eric Z. Chen, Hieu Tran, Hong Yu, Weijing Huang, Terrence Chen