PPG-to-vital-sign reconstruction turns a wrist-worn photoplethysmogram into clinical waveforms such as the ECG. Long-horizon multivariate time-series forecasting underpins planning in energy, weather,...
PulseBound is a photoplethysmography (PPG) representation learner that enforces an explicit stored‑window information boundary, ensuring that encoder inputs depend only on a visible prefix and a content‑independent cutoff. By combining physiologically structured future‑beat prediction with prefix‑only normalization, suffix replacement, and aligned masking, PulseBound achieves stored‑suffix invariance, preventing changes in the stored suffix from affecting forecast context or predictions. Evaluated on MIMIC and VitalDB datasets, PulseBound reduces mean absolute error by over 22% compared to last‑visible‑beat persistence and outperforms seven other models on nine frozen linear‑probe and seven full‑fine‑tuning downstream tasks.
By Chenyang Xu, Donglin Xie, Xi Xiang, Xiaoyu Li, Yufan Lu, Jiqiun Gao, Yi Zhao, Xin-Yi Li, Guangpu Zhu, Zijian Wang, Xiwen Yang, Dezhen Wang, Lin Chen, Shenda Hong, Leilei Li
arXiv:2606. 15284v1 Announce Type: cross Abstract: Photoplethysmography (PPG) plays a central role in wearable health monitoring and clinical decision support.
By Chenyang He, Xinyi Shao, Shun Huang, Bosong Huang, Daoqiang Zhang, Ming Jing, Cheng Ding
PGP-Clinical-TimeKAN is a trajectory-first framework for joint probabilistic forecasting of multivariate physiological data, combining missingness-aware temporal encoders, a soft organ-system prior, patient-specific relations, nonlinear Kolmogorov‑Arnold messages, and a low‑rank multivariate Student‑t head. Evaluated on a MIMIC‑IV cohort of 6,882 patients, it achieves the second‑lowest normalized MAE and the lowest RMSE among 13 models, while providing calibrated probabilistic forecasts with empirical coverage at 50%, 80%, and 95% intervals. Ablation studies show that relational structure is critical for performance, and increasing covariance rank improves likelihood but not point accuracy.
whyItMatters":"The model demonstrates that joint trajectory forecasting can yield highly accurate, calibrated predictions of physiological trajectories, offering a potentially inspectable intermediate task for clinical deterioration prediction."
By Weizhi Nie, Rihao Chang, Weijie Wang, Yuting Su
arXiv:2607. 20027v1 Announce Type: new Abstract: Short-term Heart Rate Variability (HRV) forecasting could provide clinicians with actionable lead time for detecting autonomic dysfunction and adverse cardiac events.
By Luukas Per\"akyl\"a, Fahad Sohrab, Ville Hautam\"aki, Merja Hein\"aniemi, Sui Huang, Pekka Abrahamsson
arXiv:2608. 12592v1 Announce Type: new Abstract: Continuous physiological time series underpin modern clinical monitoring, yet many of the most informative signals are invasive, expensive, or simply unavailable for a given patient.
By Haochen Zhang, Jiaheng Guo, Yu-Chao Huang, Nicholas Knoz, Tianlong Chen