From Data to Valves: A Self-Learning, Production-Grade Edge Stack for Sustainable HVAC Control
Read the original on Hugging Face Trending Papers →The Flow has not summarised this story yet — read it at Hugging Face Trending Papers.
The Flow has not summarised this story yet — read it at Hugging Face Trending Papers.
The paper introduces a production-ready edge stack for HVAC control that runs entirely on an NVIDIA Jetson Orin gateway. It comprises three learning components: a transformer‑encoder forecaster that predicts unit temperatures and adapts in real time, a distributional soft actor‑critic agent that determines chilled‑water valve positions while respecting safety envelopes, and a change‑point regression baseline that provides a counterfactual for savings certification. Over eighteen months of hotel data, the forecaster converges quickly and achieves low prediction errors, while the RL agent operates in shadow mode across 104 units with documented latency and memory usage.
arXiv:2611.22144v1 Announce Type: cross Abstract: Deep reinforcement learning (DRL) is often proposed for the supervisory control of heating, ventilation and air-conditioning (HVAC) systems. The repo...
arXiv:2510. 01475v2 Announce Type: replace-cross Abstract: Model Predictive Control (MPC) has demonstrated significant performance improvements over today's control methods for residential Heating, Ventilation, and Air Conditioning (HVAC), but deploying MPC often requires substantial engineering effort.
The study evaluates whether a large language model (LLM) can manage multi‑zone variable‑air‑volume HVAC control without building‑specific training, and whether reinforcement fine‑tuning verified by rollout can enhance a smaller, deployable model. Five controllers were tested in a physics‑based four‑zone emulator over five summer days; the LLM (GPT‑5) reduced electricity use by 6.8‑7.4% compared to a guideline baseline but performed worse on outdoor‑air usage and CO₂ compliance. A reinforcement‑learning controller achieved a 4.5% electricity savings while improving temperature and CO₂ compliance, yet its critic’s high correlation with deterministic rollout did not reliably rank actions, and fine‑tuning a smaller LLM with rollout returns yielded no sustained performance gains due to unreliable next‑state predictions.
arXiv:2607. 27914v1 Announce Type: new Abstract: Multi-zone variable-air-volume control must balance thermal comfort, indoor air quality, and electricity use across several continuous actuators.
NeuralBES is a differentiable emulator that blends a physics‑based resistance–capacitance thermal model with a shared neural encoder to predict building energy use. By mapping building metadata to physically bounded model coefficients, it solves a scalar linear recurrence in log‑space and uses a predictor–corrector loop to handle thermostat nonlinearity while maintaining full‑horizon gradient flow. Trained on the ResStock dataset, NeuralBES accurately models heterogeneous buildings across climate zones, achieving physics‑valid predictions with fewer parameters than transformer and recurrent baselines and outperforming grey‑box RC models in mean absolute percentage error.