When does deep reinforcement learning pay off in HVAC supervisory control? Four small Modelica case studies trained directly on FMUs
Read the original on arXiv AI →The Flow has not summarised this story yet — read it at arXiv AI.
The Flow has not summarised this story yet — read it at arXiv AI.
arXiv:2510. 01475v2 Announce Type: replace-cross Abstract: Model Predictive Control (MPC) has demonstrated significant performance improvements over today's control methods for residential Heating, Ventilation, and Air Conditioning (HVAC), but deploying MPC often requires substantial engineering effort.
The study evaluates whether a large language model (LLM) can manage multi‑zone variable‑air‑volume HVAC control without building‑specific training, and whether reinforcement fine‑tuning verified by rollout can enhance a smaller, deployable model. Five controllers were tested in a physics‑based four‑zone emulator over five summer days; the LLM (GPT‑5) reduced electricity use by 6.8‑7.4% compared to a guideline baseline but performed worse on outdoor‑air usage and CO₂ compliance. A reinforcement‑learning controller achieved a 4.5% electricity savings while improving temperature and CO₂ compliance, yet its critic’s high correlation with deterministic rollout did not reliably rank actions, and fine‑tuning a smaller LLM with rollout returns yielded no sustained performance gains due to unreliable next‑state predictions.
The paper introduces a production-ready edge stack for HVAC control that runs entirely on an NVIDIA Jetson Orin gateway. It comprises three learning components: a transformer‑encoder forecaster that predicts unit temperatures and adapts in real time, a distributional soft actor‑critic agent that determines chilled‑water valve positions while respecting safety envelopes, and a change‑point regression baseline that provides a counterfactual for savings certification. Over eighteen months of hotel data, the forecaster converges quickly and achieves low prediction errors, while the RL agent operates in shadow mode across 104 units with documented latency and memory usage.
Learned HVAC controllers rarely leave the simulator, and those that do are typically trained offline, frozen at deployment and retrained from the cloud. We present a production stack in which three le...
arXiv:2606. 01665v1 Announce Type: new Abstract: We quantify the energy floor -- the minimum achievable cost given action space constraints -- for Soft Actor-Critic (SAC) HVAC control on the sbsim calibrated building simulator.
arXiv:2607. 27914v1 Announce Type: new Abstract: Multi-zone variable-air-volume control must balance thermal comfort, indoor air quality, and electricity use across several continuous actuators.