arXiv:2605. 28912v2 Announce Type: replace Abstract: The rapid growth of AI-driven data centers and large-scale energy storage systems is increasing the reliance of power system operation on real-time measurement data and automated decision-making.
By Xin Li, Chenhan Xiao, Jonathan Cohen, Aviad Elyashar, Yang Weng, Rami Puzis
arXiv:2606. 08473v1 Announce Type: new Abstract: False data injection attacks (FDIAs) introducing small measurement perturbations can still cause large deviations in power system state estimation when the injected signals align with the pseudo-null space of the system model.
By Xin Li, Chenhan Xiao, Jonathan Cohen, Aviad Elyashar, Yang Weng, Rami Puzis
The paper introduces PCGAN, a physics-constrained generative adversarial network that learns power‑flow sensitivities from historical sensor data to craft stealthy false data injection attacks on smart grids. PCGAN limits perturbations to compromised channels while producing realistic spatiotemporal patterns, and it outperforms seven existing attacks on the IEEE 300‑bus system across various levels of sensor compromise. The study evaluates PCGAN’s stealth against ten machine‑learning detectors and conventional bad‑data detection methods, showing high evasion rates and significant physical impact, thereby offering challenging scenarios for detector evaluation.
By Md. Mainul Islam, Hasan Kurban, Abdulrahman Takiddin, Muhammad Ismail, Rachad Atat, Erchin Serpedin
arXiv:2606. 06347v1 Announce Type: cross Abstract: This paper addresses the problem of attack detection in cyber-physical systems without any knowledge of the plant model or its structure.
By Sribalaji C. Anand, Anh Tung Nguyen, George J. Pappas
The paper evaluates three machine‑learning fault detectors—gradient‑boosted trees, a convolutional neural network, and logistic regression—against a reference sequence‑current method on 9,022 simulated 90 kV line fault episodes. Using a protection‑oriented assessment framework that includes multiple window conditions, causal labeling, episode‑grouped cross‑validation, and a fixed security budget, the authors report near‑perfect AUC‑ROC (>0.999) but reveal that missed‑trip rates can reach 1.99 % and false‑trip rates 0.12–0.16 % per window, with nuisance assertions in 11.3–19.1 % of episodes. The study also finds that higher fault resistance correlates most consistently with missed trips and that a fault‑current gradient is only partially captured by waveform‑derived current.
whyItMatters":"The assessment demonstrates that high aggregate performance metrics can mask significant protection‑relevant errors, highlighting the need for protection‑oriented evaluation of ML fault detectors."
By Julian Oelhaf, Georg Kordowich, Changhun Kim, Christian Bergler, Andreas Maier, Johann J\"ager, Siming Bayer
Grid foundation models (GridFMs) are graph transformers pretrained on a masked power-flow objective, and evaluate power flow orders of magnitude faster than an iterative solver. Their size, however, t...