The study developed a Vision Transformer-based deep learning model with uncertainty estimation to detect glaucoma from colour fundus photographs across multi‑ethnic populations, including those with high myopia. Using 56,483 images for training, the model achieved an internal AUROC of 98.7% and maintained high performance (AUROC 86.4–99.6%) on 16 external datasets from eight countries. In high‑myopia eyes, the model outperformed ophthalmologists and matched specialists when full clinical data were available.
By Raghavan Lavanya, Yangqin Feng, Ten Cheer Quek, Quan V. Hoang, Linda Yi-Chieh Poon, Jost B. Jonas, Ya Xing Wang, Vinay Nangia, Jin Wook Jeoung, Sehie Park, SoYeon Kim, Benjamin Y Xu, Sreenidhi Iyengar Munimadugu, Paul Mitchell, Gerald Liew, Yanin Suwan, Jirayu Hong-amata, Sahil Thakur, Monisha E Nongipur, Tina Wong, Rahat Husain, Ng Si Rui, Yamon Syn, Phey Feng Lo, Nicholas Tan Yi Qiang, Shaista Hussain, Xiaofeng Lei, Zhi Da Soh, Marco Yu, Haslina Hamzah, Zizhou Wang, Yan Wang, Liangli Zhen, Xinxing Xu, Tien-Yin Wong, Tin Aung, Rachel S Chong, Yong Liu, Ching-Yu Cheng
arXiv:2608.24723v1 Announce Type: new
Abstract: Retinal fundus photography is widely used for screening and monitoring ocular diseases, but many modern classification pipelines rely on deep latent re...
By Xiaoyan Li, Shixin Xu, Arvind Gupta, Huaxiong Huang
Background: Artificial intelligence (AI)-based glaucoma detection from colour fundus photographs (CFP) offers scalable screening, but performance may decline on external datasets because of difference...
The paper investigates how pre‑training strategy, dataset size, and domain affect uncertainty estimation in vision medical foundation models. It compares point‑prediction calibration with conformal (region) prediction across retinal, histopathological, and chest X‑ray models, finding that domain‑specific, self‑supervised pre‑training yields better calibration and more efficient conformal sets. The study shows that standard recalibration alone cannot fully reconcile uncertainty differences between models trained on different data sources.
By Haoxu Huang, Narges Razavian
arXiv:2508. 03750v2 Announce Type: replace Abstract: Early and accurate glaucoma detection is critical to prevent irreversible vision loss, yet existing AI methods often rely on unimodal inputs and lack interpretability.
By Cheng Huang, Zeyu Han, Weizheng Xie, Karanjit Kooner, Tsengdar Lee, Jui-Kai Wang, Jia Zhang
arXiv:2608. 07651v1 Announce Type: new Abstract: Large language models (LLMs) show promise in medical image interpretation but suffer from hallucination, limited accuracy, and run-to-run inconsistency.
By Jalil Jalili, Hossein Taghizad, Anuwat Jiravarnsirikul, Christopher Bowd, Akram Belghith, Raheleh Kafieh, Christopher A. Girkin, Sally L. Baxter, Robert N. Weinreb, Linda M. Zangwill, Mark Christopher