arXiv:2607.13682v4 Announce Type: replace-cross
Abstract: Does an uncertainty map identify where a reconstruction is wrong? In sparse-view computed tomography (CT), we find a sharp gap between whole-...
By Chulin Zhao, Yiran Xu, Shu Liu
arXiv:2607. 13682v2 Announce Type: cross Abstract: Radiative Gaussian splatting reconstructs sparse-view CT fast and accurately, and recent work attaches per-Gaussian posteriors to yield per-voxel uncertainty maps.
By Chulin Zhao, Yiran Xu, Shu Liu
arXiv:2608.29705v1 Announce Type: cross
Abstract: Feed-forward 3D reconstruction models emit a per-pixel confidence that downstream systems read as a reliability signal. It is trained as a loss weigh...
By Nanxing Nick Deng, Qing Cheng, Niclas Zeller, Daniel Cremers
SpatialUQ is a post‑hoc uncertainty quantification method that uses only the output probabilities of frozen black‑box vision models. It computes the Jensen‑Shannon divergence between the global prediction and the mean of five fixed spatial crops across six deterministic forward passes, assuming that trustworthy predictions are spatially consistent. On the NIH ChestX‑ray14 dataset, SpatialUQ’s Multicrop Uncertainty Score (MUS) achieves a 0.784 failure‑detection AUC—significantly higher than MC‑Dropout—while also providing superior native calibration and improving further when fused with other uncertainty signals.
By Md Kawsher Mahbub, Milon Biswas, Mirza Niaz Morshed, Wei Yu
The paper presents a closed‑loop system for registering segmented CT fracture fragments to fluoroscopy, providing calibrated uncertainty bounds and flagging implausible or ambiguous fragments. After each shot, the system updates all fragment registrations, stops or plans the next view based on whether new views keep fragment positions within their bounds, and uses uncertainty‑driven planning to reduce the number of shots needed. Experiments on simulated fluoroscopy of 60 held‑out pelvic fractures show that 95% of the bounds cover 83% of unflagged fragments, with 91% of those within 5 mm, and that a simple rule requiring no fragment to move beyond its bound reduces false stops from 23% to 6% at a 2 mm threshold.
"whyItMatters":"The study demonstrates that calibrated uncertainty and view‑planning can make multi‑fragment 2D/3D registration reliable enough to guide pelvic fracture surgery, potentially improving surgical accuracy and efficiency."
By Bowen Xiang, Michael I. Miga
arXiv:2606. 15910v2 Announce Type: replace Abstract: A vision-language model can answer a question about a chest radiograph or a pathology slide fluently and confidently while barely using the image, relying instead on language priors.
By Reza Khanmohammadi, Kundan Thind, Mohammad M. Ghassemi