arXiv Computer Vision

Medical Imaging AI Competitions Lack Fairness

Benchmarking competitions are central to AI development in medical imaging, but it is unclear if they provide representative, accessible, and reusable data for clinical relevance. This study systematically examined 249 challenges (458 tasks) across 19 imaging modalities, finding limited geographic, modality, and problem-type representation. Additionally, many datasets suffer from restrictive access, ambiguous licensing, and poor documentation, hindering reproducibility and long-term reuse.

arXiv Computer Vision
Aug 25

Can Coding Agents Build Robust Baselines? A Skill-Based Approach for Automating the Medical Imaging Model-Development Pipeline

The paper introduces an agentic AI Scientist workflow that automates the entire baseline development process for medical imaging by combining literature-guided reasoning, automated code generation, and hypothesis-driven experimentation. Evaluated on four public benchmarks covering segmentation, classification, and detection, the pipeline consistently improves validation performance, achieving competitive leaderboard results such as 6th place on both PUMA tracks and 31st on MILK10k. The approach also shows strong domain generalization on MIDOG25 across scanners, tumor types, and species, demonstrating that a skill-based, literature-guided agentic workflow can reduce engineering effort without task-specific redesign.

By Eugenia Moris, Jos\'e Ignacio Orlando
arXiv Computer Vision
Sep 15

Designing UNICORN: a Unified Benchmark for Imaging in Computational Pathology, Radiology, and Natural Language

arXiv:2603.02790v2 Announce Type: replace Abstract: Foundation models are changing the way we develop medical artificial intelligence. By learning broadly generalizable features across diverse data m...

By Michelle Stegeman (and on behalf of the UNICORN consortium), Lena Philipp (and on behalf of the UNICORN consortium), Fennie van der Graaf (and on behalf of the UNICORN consortium), Marina D'Amato (and on behalf of the UNICORN consortium), Cl\'ement Grisi (and on behalf of the UNICORN consortium), Luc Builtjes (and on behalf of the UNICORN consortium), Joeran S. Bosma (and on behalf of the UNICORN consortium), Judith Lefkes (and on behalf of the UNICORN consortium), Rianne A. Weber (and on behalf of the UNICORN consortium), James A. Meakin (and on behalf of the UNICORN consortium), Thomas Koopman (and on behalf of the UNICORN consortium), Anne Mickan (and on behalf of the UNICORN consortium), Mathias Prokop (and on behalf of the UNICORN consortium), Ewoud J. Smit (and on behalf of the UNICORN consortium), Fr\'ed\'erique Meeuwsen (and on behalf of the UNICORN consortium), Geert Litjens (and on behalf of the UNICORN consortium), Jeroen van der Laak (and on behalf of the UNICORN consortium), Bram van Ginneken (and on behalf of the UNICORN consortium), Maarten de Rooij (and on behalf of the UNICORN consortium), Henkjan Huisman (and on behalf of the UNICORN consortium), Colin Jacobs (and on behalf of the UNICORN consortium), Francesco Ciompi (and on behalf of the UNICORN consortium), Alessa Hering (and on behalf of the UNICORN consortium)
arXiv AI
Jun 10

People-Centred Medical Image Analysis via Fairness-Aware Human-AI Cooperation

arXiv:2604. 26991v2 Announce Type: replace-cross Abstract: Machine learning models for medical image analysis often exhibit subgroup-dependent performance, which impacts how decisions should be allocated between automated systems and human experts under limited resources.

By Zheng Zhang, Milad Masroor, Cuong Nguyen, Tahir Hassan, Yuanhong Chen, David Rosewarne, Kevin Wells, Thanh-Toan Do, Gustavo Carneiro
arXiv Computer Vision
Sep 7

Solve the Missing First Step: Can VLMs Standardize Raw Heterogeneous Medical Data?

The paper introduces the Medical Data Standardization Benchmark (MDS‑Bench), which evaluates vision‑language models (VLMs) on their ability to process raw, heterogeneous medical data. Models must identify source formats, convert raw images into VLM‑compatible inputs, extract relevant text, and organize the results into structured image‑text pairs. Experiments show that even the top VLM, Gemini 3 Flash, achieves only a 48.6% end‑to‑end success rate, underscoring the challenge of raw data standardization in clinical settings.

By Xin Chen, Dongliang Xu, Cunhao Zhu, Xudong Luo, Haoyang Lyu, Xiaoxiao Sun, Serena Yeung-Levy, Yue Yao
Hugging Face Trending Papers
Jul 6

Solve the Missing First Step: Can VLMs Standardize Raw Heterogeneous Medical Data?

As vision-language models (VLMs) are increasingly applied to medical AI, existing benchmarks mainly focus on evaluating their diagnosis ability over given medical images and texts, implicitly assuming that standardized medical images, texts or question-answer pairs are already prepared. However, this assumption does not hold when we apply VLMs in real clinical practice, where medical data is often raw, heterogeneous, and fragmented across different sources.

arXiv AI
Aug 11

Ethical Framework for Responsible Foundational Models in Medical Imaging

arXiv:2406. 11868v2 Announce Type: replace-cross Abstract: The emergence of foundational models represents a paradigm shift in medical imaging, offering extraordinary capabilities in disease detection, diagnosis, and treatment planning.

By Debesh Jha, Gorkem Durak, Abhijit Das, Jasmer Sanjotra, Onkar Susladkar, Suramyaa Sarkar, Ashish Rauniyar, Nikhil Kumar Tomar, Linkai Peng, Sirui Li, Koushik Biswas, Ertugrul Aktas, Elif Keles, Matthew Antalek, Zheyuan Zhang, Bin Wang, Xin Zhu, Hongyi Pan, Deniz Seyithanoglu, Alpay Medetalibeyoglu, Vanshali Sharma, Vedat Cicek, Amir A. Rahsepar, Rutger Hendrix, A. Enis Cetin, Bulent Aydogan, Mohamed Abazeed, Frank H. Miller, Rajesh N. Keswani, Hatice Savas, Sachin Jambawalikar, Daniela P. Ladner, Amir A. Borhani, Concetto Spampinato, Michael B. Wallace, Ulas Bagci